| 
 
 Sun Fire X4600 M2CPU/Memory BoardOptions 8107A-Z / 8108A-Z / 8109A-Z / 8110A-Z / 8115A-Z
| 501-7321 |  
| Centaurus w/o processor w/o Heatsink 310-0059
 w/o Backplate 541-0465
 L
 |  
| 2.4GHz Dual-Core
 | 2.6GHz Dual-Core
 | 2.8GHz Dual-Core
 | 2.8GHz Dual-Core
 | 3.2GHz Dual-Core
 |  
| 541-2196 | 541-1835 | 541-2045 | 541-2197 | 541-2744 |  
| 0MB Assy/FRU Opteron 8216
 F3 Stepping
 8000 Series Socket F
 Option 8107A-Z
 L
 | 0MB Assy/FRU Opteron 8218
 F2 Stepping
 8000 Series Socket F
 Option 8108A-Z
 L
 | 0MB Assy/FRU Opteron 8220SE
 F3 Stepping
 8000 Series Socket F
 Option 8109A-Z
 L
 | 0MB Assy/FRU Opteron 8220
 F3 Stepping
 8000 Series Socket F
 Option 8110A-Z
 L
 | 0MB Assy/FRU Opteron 8224SE
 F3 Stepping
 8000 Series Socket F
 Option 8115A-Z
 L
 |  
Go to 501-7735Go to 501-7817
  
 
 
| Sun Fire X4600 M2 Codename: Galaxy 4F |  Notes
The minimum Solaris operating system is Solaris 10 01/06 x64.
Two, Four, Six, and Eight CPU/Memory Module configurations are supported.
PCI Slots 5, 6, and 7 are not usable in two CPU/Memory Module
    configurations.
Mixing CPU speeds or mixing single-, dual- and quad-core CPUs
    is not supported.
DIMM pairs require matching characteristics including manufacturer, size,
    and speed.
Install the first DIMM pair in DIMM2/DIMM3 - Pair 1 (white)and the second DIMM pair in DIMM0/DIMM1 - Pair 0 (black).
Fault Remind Button SW1 lights the CPU/Memory fault LEDs for up to
    one minute.
DIMM Fault LEDs do not function correctly.
    Refer to BugIDs 6403209 and 6420909.
Replace faulty DIMMs as a pair. The DIMM FRU includes two matching DIMMs.
 References
 Integrated Lights-Out Manager Administration Guide for ILOM 1.0, 819-1160. Integrated Lights-Out Manager Administration Guide for ILOM 1.1.1, 820-0280. Sun Fire X4600 and X4600 M2 Servers Installation Guide, 819-4341. Sun Fire X4600 and X4600 M2 Servers Service Manual, 819-4342. Sun Fire X4600 and X4600 M2 Servers Diagnostics Guide, 819-4343. Sun Fire X4600 M2 Server Product Notes, 819-5032. Sun Fire X4600 to Sun Fire X4600 M2 Server Migration, 819-5040. Integrated Lights Out Manager for Sun Fire X4600 and X4600 M2 Servers, 819-5432. 
 
 
 Sun Fire X4600 M2CPU/Memory BoardOptions 8111A-Z / 8113A-Z
| 501-7735 |  
| Helix w/o processor w/o Heatsink 310-0130
 w/o Backplate 541-2261
 L
 |  
| 2.8GHz Dual-Core
 | 3.0GHz Dual-Core
 |  
| 541-2262 | 541-2403 |  
| Helix 0MB Assy/FRU Opteron 8220
 F3 Stepping
 8000 Series Socket F
 Option 8113A-Z
 L
 | Helix 0MB Assy/FRU Opteron 8222
 F3 Stepping
 8000 Series Socket F
 Option 8110A-Z
 L
 |  
Go to 501-7321Go to 501-7817
  
 
 
| Sun Fire X4600 M2 Codename: Galaxy 4F |  Notes
The minimum Solaris operating system is Solaris 10 01/06 x64.
Two, Four, Six, and Eight CPU/Memory Module configurations are supported.
PCI Slots 5, 6, and 7 are not usable in two CPU/Memory Module
    configurations.
Mixing CPU speeds or mixing single-, dual- and quad-core CPUs
    is not supported.
DIMM pairs require matching characteristics including manufacturer, size,
    and speed.
Fault Remind Button SW1 lights the CPU/Memory fault LEDs for up to
    one minute.
DIMM Fault LEDs do not function correctly.
    Refer to BugIDs 6403209 and 6420909.
Replace faulty DIMMs as a pair. The DIMM FRU includes two matching DIMMs.
A222 Power Supply 300-2013 or A238 Power Supply 300-2158 is required.Option X4094A-Z includes four 300-2013.
    Option X5009A-Z includes four 300-2158.
 References
 Integrated Lights-Out Manager Administration Guide for ILOM 1.0, 819-1160. Integrated Lights-Out Manager Administration Guide for ILOM 1.1.1, 820-0280. Sun Fire X4600 and X4600 M2 Servers Installation Guide, 819-4341. Sun Fire X4600 and X4600 M2 Servers Service Manual, 819-4342. Sun Fire X4600 and X4600 M2 Servers Diagnostics Guide, 819-4343. Sun Fire X4600 M2 Server Product Notes, 819-5032. Sun Fire X4600 to Sun Fire X4600 M2 Server Migration, 819-5040. Integrated Lights Out Manager for Sun Fire X4600 and X4600 M2 Servers, 819-5432. 
 
 
 Sun Fire X4600 M2CPU/Memory BoardOptions 8226A-Z / 8229A-Z / 8233A-Z / 8472A / 8474A / 8476A
| 501-7817 |  
| Vortex w/o processor w/o Heatsink 310-0130
 w/o Backplate 541-2261
 L
 |  
| 1.9GHz Quad-Core
 | 2.3GHz Quad-Core
 | 2.5GHz Quad-Core
 |  
| 541-1314 | 541-2785 | 541-2783 |  
| Vortex 0MB Assy/FRU Opteron 8347HE
 Barcelona
 B3 Stepping
 8000 Series Socket F
 Option 8226A-Z
 L
 | Vortex 0MB Assy/FRU Opteron 8356
 Barcelona
 B3 Stepping
 8000 Series Socket F
 Option 8229A-Z
 L
 | Vortex 0MB Assy/FRU Opteron 8360SE
 Barcelona
 B3 Stepping
 8000 Series Socket F
 Option 8233A-Z
 L
 |  
| 2.3GHz Quad-Core
 | 2.5GHz Quad-Core
 | 2.7GHz Quad-Core
 | 2.9GHz Quad-Core
 |  
| 541-3847 | 541-3675 | 541-3676 | 541-3867 |  
| Vortex 0MB Assy/FRU Opteron 8376HE
 Shanghai
 C2 Stepping
 8000 Series Socket F
 Option 8472A
 L
 | Vortex 0MB Assy/FRU Opteron 8380
 Shanghai
 C2 Stepping
 8000 Series Socket F
 Option 8474A
 L
 | Vortex 0MB Assy/FRU Opteron 8384
 Shanghai
 C2 Stepping
 8000 Series Socket F
 Option 8476A
 L
 | Vortex 0MB Assy/FRU Opteron 8389
 Shanghai
 C2 Stepping
 8000 Series Socket F
 Option 8478A
 L
 |  
Go to 501-7321Go to 501-7735
  
 
 
| Sun Fire X4600 M2 Codename: Galaxy 4F |  Notes
The minimum Solaris operating system is Solaris 10 08/07 (U4) x64.
The minimum Solaris operating system for the Opteron 8380/8384 is Solaris 10 10/08 x64. 
Two, Four, Six, and Eight CPU/Memory Module configurations are supported.
PCI Slots 5, 6, and 7 are not usable in two CPU/Memory Module
    configurations.
Mixing CPU speeds or mixing single-, dual- and quad-core CPUs
    is not supported.
DIMM pairs require matching characteristics including manufacturer, size,
    and speed.
Fault Remind Button SW1 lights the CPU/Memory fault LEDs for up to
    one minute.
Replace faulty DIMMs as a pair. The DIMM FRU includes two matching DIMMs.
BIOS 0ABIT87 adds AMD Quad Core Opteron (Barcelona) support.
BIOS 0ABIT114 adds support to AMD Quad Core Opteron Models
    8380 and 8384 (Shanghai).
Barcelona CPU:
    A222 Power Supply 300-2013 or A238 Power Supply 300-2158 is required.Shanghai CPU:
    A238 Power Supply 300-2158 is required.
Option X4094A-Z includes four 300-2013.Option X5009A-Z includes four 300-2158.
 References
 Integrated Lights-Out Manager Administration Guide for ILOM 1.0, 819-11
60. Integrated Lights-Out Manager Administration Guide for ILOM 1.1.1, 820-
0280. Sun Fire X4600 and X4600 M2 Servers Installation Guide, 819-4341. Sun Fire X4600 and X4600 M2 Servers Service Manual, 819-4342. Sun Fire X4600 and X4600 M2 Servers Diagnostics Guide, 819-4343. Sun Fire X4600 M2 Server Product Notes, 819-5032. Sun Fire X4600 to Sun Fire X4600 M2 Server Migration, 819-5040. Integrated Lights Out Manager for Sun Fire X4600 and X4600 M2 Servers,
819-5432. 
 |