 System ControllerSun Fire 3800 
 Jumper Settings
* Jumpers J2303 and J2304 must be set identically.
| JUMPER | PINS | SETTING | DESCRIPTION |  
| J1301 | 1-2 2-3
 | In In
 | Select ROMBO Select FPROM (default)
 |  
| J1303 | 1-2 1-2
 | In Out
 | FPROM write enable (default) FPROM write protect
 |  
| J2303* | 1-2 2-3
 | In In
 | RS232 +12Vdc RS423 +5Vdc (default)
 |  
| J2304* | 1-2 2-3
 | In In
 | RS232 -12Vdc RS423 -5Vdc (default)
 |  
 
| Sun Fire 3800-6800 Codename: Serengeti |  Notes
The minimum operating system is Solaris 8 4/01.
System Controller slots are labeled SSC0 and SSC1.
Pressing the Reset switch reloads the System Controller software
    (attempting a SC reboot first is recommended).
Resetting the System Controller with OBP >/=5.12 can bring down running 
    domains if the System Controller is performing a JTAG operation.
Shut down running domains before resetting the System Controller.
A System Controller reboot does not affect running domains.
 
How To article 1005873.1 provides 
    a "ftp-only" shortcut for updating the flashprom firmware.
 
To obtain the system serial number, use the SC command:
  showplatform -p mac See
  805-7372
    for details. References
 Sun Fire Systems Service Manual, 805-7363. Sun Fire Systems Platform Administration Manual, 805-7373. Sun Fire System Controller Command Reference Manual, 805-7372. 
 |