System Controller
Sun Fire 4800 / 4810 / 6800
Jumper Settings
JUMPER |
PINS |
SETTING |
DESCRIPTION |
J1301 |
1-2 2-3 |
In In |
Select ROMBO
Select FPROM (default) |
J1303 |
1-2 1-2 |
In Out |
FPROM write enable (default)
FPROM write protect |
J2303* |
1-2 2-3 |
In In |
RS232 +12Vdc RS423 +5Vdc (default) |
J2304* |
1-2 2-3 |
In In |
RS232 -12Vdc RS423 -5Vdc (default) |
* Jumpers J2303 and J2304 must be set identically.
Notes
- The minimum operating system is Solaris 8 4/01.
- System Controller slots are labeled SSC0 and SSC1.
- Pressing the Reset switch reloads the System Controller software
(attempting a SC reboot first is recommended).
- Resetting the System Controller with OBP >/=5.12 can bring down running
domains if the System Controller is performing a JTAG operation.
- Shut down running domains before resetting the System Controller.
- A System Controller reboot does not affect running domains.
- How To article 1005873.1 provides
a "ftp-only" shortcut for updating the flashprom firmware.
- Version 1 (501-5407) and Version 2 (501-6631) System Controllers
cannot be mixed within a system, and cannot substitute for each
other.
- To obtain the system serial number, use the SC command:
showplatform -p mac
See 805-7372
for details.
References
-
Sun Fire Systems Service Manual, 805-7363.
-
Sun Fire Systems Platform Administration Manual, 805-7373.
-
Sun Fire System Controller Command Reference Manual, 805-7372.
|