Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | ||
|
|||
Sun StorEdge[tm] 6020/6120 Array SIS LEDsArray Unit Service Indicator Standard (SIS) LEDs | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| White | Amber | Green | Function |
|---|---|---|---|
|
Off
|
Off
|
Off
|
Array is not powered (no AC power) |
|
Off
|
n/a
|
On
|
No locator action is active to this enclosure |
|
On
|
n/a
|
On
|
A locator action is underway for this enclosure |
|
n/a
|
Off
|
On
|
Array is powered on to standby or to full power and no service action is required |
|
n/a
|
On
|
On
|
A service action is required for an included FRU and the array is powered on to standby or to full power |
|
Fast Blink *
|
Fast Blink
|
On
|
Array is performing power-on test or enclosure LED check |
| * - Fast Blink is measured as four blinks per second. | |||

| Blue | Amber | Green | Function |
|---|---|---|---|
|
Off
|
Off
|
Off
|
Drive not mated or not powered on |
|
On
|
Off
|
Off
|
OK to remove; not ready; software deconfigured; drive mated, powered on |
|
Off
|
Off
|
Slow Blink *
|
Not ready; drive powered on; either spinning up or down or waiting for the spin-up command |
|
Off
|
Off
|
On
|
Ready; drive spun-up |
|
Off
|
Off
|
Mainly on, flashing off at a visible frequency
|
Ready with SCSI activity |
|
Off
|
On
|
On
|
Drive service action required; drive ready; not OK to remove |
|
Off
|
On
|
Slow Blink
|
Drive service action required; drive not ready; not OK to remove |
|
On
|
On
|
Off
|
OK to remove; drive service action required; drive not ready; software deconfigured |
|
On
|
Off
|
Slow Blink
|
OK to remove; not ready; software deconfigured; powered on; either spinning up or down or waiting for the spin-up command |
|
Fast Blink *
|
Fast Blink
|
n/a
|
Array power-on test, drive insertion test, or array LED check |
| * - Slow Blink is measured as one second on and one second off. Fast Blink is measured as four blinks per second. | |||
| CAUTION - During a data reconstruction on the disk drive, the blue SIS LED will light indicating a ready to replace state for the drive. Do not remove the drive at this time as this is a false LED signal. | |||

| Blue | Amber | Green | Function |
|---|---|---|---|
|
Off
|
Off
|
Off
|
PCU not mated; no AC power, or normal state for PCU in standby |
|
Off
|
Off
|
On
|
PCU ready; all voltages at rated value |
|
Off
|
Off
|
Fast Blink *
|
PCU ready, battery power available, and all DC voltages within tolerance |
|
Off
|
On
|
On
|
PCU service action is required; PCU ready |
|
Off
|
On
|
Off
|
PCU service action is required; PCU not ready |
|
On
|
On
|
Off
|
OK to remove; PCU service action is required; PCU not ready; PCU is software deconfigured |
|
On
|
Off
|
Off
|
OK to remove; PCU is software deconfigured; no service action required |
|
Fast Blink
|
Fast Blink
|
Fast Blink
|
Array power-on test, PCU insertion test, or array LED test |
| * - Fast Blink is measured as four blinks per second. | |||

|
Interconnect Card SIS LEDs
|
|||
|---|---|---|---|
| Blue | Amber | Green | Function |
|
Off
|
Off
|
Off
|
Interconnect card not mated or no standby power |
|
Off
|
Off
|
On
|
Ready; standby power OK |
|
Off
|
On
|
On
|
Interconnect card service action required; interconnect card ready |
|
Off
|
On
|
Off
|
Interconnect card service action required; interconnect card not ready |
|
On
|
Off
|
Off
|
OK to remove; not ready; software deconfigured |
|
On
|
On
|
Off
|
OK to remove; interconnect card service action required; interconnect card not ready; interconnect card is software deconfigured |
|
Fast Blink *
|
Fast Blink
|
Fast Blink
|
Array power-on test, interconnect card insertion test, or array LED check |
| * - Fast Blink is measured as four blinks per second. | |||
|
Interconnect Card Channel Status LEDs
|
|||
| Amber | Green | Function | |
|
Off
|
On
|
Interconnect cable present; OK | |
|
Off
|
Off
|
Interconnect cable missing or port has been shut down | |
|
On
|
Off
|
Interconnect cable present; no signal detected | |

| Controller Card SIS LEDs | |||
|---|---|---|---|
| Blue | Amber | Green | Function |
|
Off
|
Off
|
Off
|
Controller not mated, not powered, or not booted |
|
Off
|
Off
|
On
|
Controller ready |
|
Off
|
On
|
On
|
Controller service action required; controller ready |
|
Off
|
On
|
Off
|
Controller service action required; controller not ready |
|
On
|
On
|
Off
|
OK to remove; controller service action required; controller not ready; controller is software deconfigured |
|
On
|
Off
|
Off
|
OK to remove; controller not ready; software deconfigured |
|
Fast Blink *
|
Fast Blink
|
n/a
|
Array power-on test, controller insertion test, or array LED check |
| * - Fast Blink is measured as four blinks per second. | |||
| FC-AL Channel Status LEDs | ||
|---|---|---|
| Green | Amber | Function |
|
Off
|
Off
|
Port disabled |
|
Off
|
On
|
Port enabled; no signal detected or Laser Fault |
|
On
|
Off
|
Port enabled; signal detected |
|
Blink
|
Off
|
Port enabled; signal detected; transferring information |
| Ethernet Channel Status LEDs | ||
| LED | Green | Function |
|
VAL/ACT
|
Off
|
Link invalid |
|
On
|
Link valid | |
|
Blink
|
Link valid and active | |
|
100 bps or 10 bps
|
On
|
100 Mbps communication speed |
|
Off
|
10 Mbps communication speed | |
|
Copyright © 2011 Sun Microsystems, Inc. All rights reserved. Feedback | |||