The Sun SPARC Enterprise T5140 / T5240 servers provides the following LED groupings:
| LED Name |
LED color |
Description |
| Locator LED and Locator button |
| White |
Enables you to identify a particular server. The LED is controlled
using one of the following methods:
Issuing the ALOM CMT setlocator on or off command
Manually press the Locator button to toggle the Locator LED on or off.
This LED provides the following indications:
Off - Normal operating state.
Fast Blink - The server received a signal as a result of one of the
preceding methods and is indicating here I am.
|
| Service Action Required LED |
Amber |
The service required LED will illuminate when any of the following
conditions occur:
A fault is detected by the system diagnostics, such as POST or ALOM
CMT
When a FRU fails, such as a power supply
|
| Power/OK LED |
Off |
Indicates the system is not running in its normal state. System
power might be off or in standby mode. The service processor might be running. |
| Green - Steady On |
Normal operating state |
| Green - Slow Blink |
Indicates that a normal transitory activity is taking place.
This could indicate the system diagnostics are running, or that the system
is booting. |
| Green - Fast Blink |
Indicates the system is running at a minimum level
in standby and is ready to be quickly returned to full function. The service
processor is running. |
| Power on/off Button |
Turns the system on and off.
- If the system is powered off, press once to power on.
- If the system is powered on, press once to initiate a graceful system
shutdown.
- If the system is powered on, press and hold for 4 seconds to initiate
an emergency shutdown.
|
| Fan Module Service LED |
Amber - Off |
Indicates a steady state, no service action is required. |
| Amber - Steady On |
Indicates a fan failure event has been acknowledged and a
service action is required on at least one of the fan modules. |
| Power Supply Service Required LED |
Amber - Off |
Indicates a steady state, no service action is required. |
| Amber - Steady On |
Indicates a power supply failure event has been acknowledged
and a service action is required on at least one PSU. |
| System Overtemperature LED |
Amber - Off |
Indicates a steady state, no service action is required. |
| Amber - Steady On |
Indicates a temperature failure event has been acknowledged
and a service action is required. |
| LED Name |
Description |
| PSU OK (Green) |
This LED is lit when the power supply DC voltage is within
tolerance. |
| PSU AC Present (Green) |
The power supply is plugged in and AC power is available, regardless of
the system power state |
| Power Supply Fault LED |
Reference Front Panel Power Supply Service Required LED listed above |
| Locator LED/ Locator button |
Reference Front Panel Power OK LED listed above |
| Service Action Required LED |
Reference Front Panel Power OK LED listed above |
Power/OK LED |
Reference Front Panel Power OK LED listed above |