Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorageTek[tm] 2540, RoHS:YL FC Array: Hardware Specifications


Disks
Disk Configuration
Sun StorageTek 2540 FC Array Up to twelve disk drives as follows:
  • 73GB 15000 RPM, 3 Gb/sec SAS
  • 146GB 15000 RPM, 3 Gb/sec SAS
  • 300GB 15000 RPM, 3 Gb/sec SAS
  • 400GB 10000 RPM, 3 Gb/sec SAS
  • 450GB 15000 RPM, 3 Gb/sec SAS
  • 500GB 7200 RPM SATA
  • 750GB 7500 RPM SATA
  • 1TB 7200 RPM SATA
Capacity
Supported drives/system per tray capacity:raw, unformatted
73GB Disk drives 12 x 73GB = 876GB
146GB Disk drives 12 x 146GB = 1.75TB
300GB Disk drives 12 x 300GB = 3.6TB
400GB Disk drives 12 x 400GB = 4.8TB
450GB Disk drives 12 x 450GB = 5.4TB
500GB Disk drives 12 x 500GB = 6.0TB
750GB Disk drives 12 × 750GB = 9TB
1TB Disk Drives 12 x 1TB = 12.0TB
Drive Specifications Form factor: 3.5 in., low-profile
Interface: Dual-ported SAS
Note 1: Dynamic capacity expansion of 5 to 36 drives - 365GB to 10.8TB.
Note 2: Up to two expansion trays are supported.
Note 3: Drive depopulation scales from 5 to 12 disk drives per tray.
Interfaces
Host interfaces/link speeds Two to four 4 Gbps FC host ports per controller tray, up to 1GB cache per controller
Other interfaces Up to two 10/100 Base-T Ethernet
Serial Up to two nine-pin RS-232 ports per dual controller tray
Environment
Heat Output
460 watts (1,571 BTU/hr.)
AC Power 515 watts (+5V @ 19A/+12V @ 35A)
Operating Temperature 10° C to 40° C (50° F to 104° F), without battery; 10° C to 35° C (50° F to 95° F), with battery
Operating Relative Humidity 20% to 80% relative humidity, noncondensing
Nonoperating Temperature -10° C to 50° C (-14° F to 122° F), without battery; -10° C to 45° C (-14° F to 113° F), with battery
Nonoperating Relative Humidity 10% to 90% relative humidity, noncondensing, max dew point is 26° C (79° F), 10 percent per hour gradient.
Operating Altitude 68.3 kPa (3,200 m), 40° C, four-hour dwell
Nonoperating Altitude 18.8 kPa (12,200 m), 0° C, four-hour dwell
Shock 33 Gs, 11msec, half-sine, three shocks per direction, all six directions
Vibration All three axes:1.2 Gs, five to 500 Hz, swept-sine, five sweep cycles, one octave per minute
Dimensions and Weights
Height 86.1 mm (3.39 in)
Width 448.6 mm (17.66 in)
Depth 540 mm (21.26 in)
Weight (maximum) 27.01 kg (59.55 lb) with 12 disks
Regulations
Note: Meets or exceeds the following requirements.
Safety and Emissions FCC Class A VCCI Class A, EN55022 Class A, EN 55024 UL BSM, C-Tick RoHS WEEE
Rack Mounting
Rack mountable in 19 inch-wide rack
Clearance and Service Access
Front 38 cm (15 in) for service access
15 cm (6 in) for cooling
Rear 38 cm (15 in) for service access
15 cm (6 in) for cooling
Airflow for cooling is from front to rear.

 


  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.