Sun StorEdge[tm] 3310 SCSI Array: Hardware Specifications
|
|
36GB |
- Seagate ST336605LC, 36.4GB - 10000 RPM, 1 inch, Ultra 160 LVD Drive
- Fujitsu MAJ3364MC, 36.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Seagate ST336753LC, 36.4GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
- Fujitsu MAS3367NC, 36.4GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
|
73GB |
- Seagate ST373307LC, 73.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Hitachi DK32EJ-72NC, 73.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Fujitsu MAP3735NC, 73.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Seagate ST373207LC, 73.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Fujitsu MAT3073NC, 73.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Seagate ST373453LC, 73.4GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
- Fujitsu MAS3735NC, 73.4GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
|
146GB |
- Seagate ST3146807LC, 146.8GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Fujitsu MAP3147NC, 146.8GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Hitachi DK32EJ-14NC, 146.8GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Seagate ST3146707LC, 146.8GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Fujitsu MAT3147NC, 146.8GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
|
300GB |
- Seagate ST3300007LC, 300B - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- Fujitsu MAT3300NC, 300B - 10000 RPM, 1 inch, Ultra 320 LVD Drive
|
|
Up to 12 Disk drives per array1 |
36.4GB Disk drives |
12 x 36.4 = 436.8GB |
73.4GB Disk drives |
12 x 73.4 = 880.8GB |
146.8GB Disk drives |
12 x 146.8 = 1.7616TB |
300GB Disk drives |
12 x 300 = 3.6TB |
1Minimum number of disk drives per array is five (5),
per JTF. |
|
Power Requirement |
AC: 90 to 132 VAC or 180 to 264 VAC, 47 to 63
Hz
DC: -36 to -75 VDC |
Input Voltage |
AC: 100 to 240 VAC, single phase
DC: -48 or -60 VDC, 18A |
Current Per Input |
AC: 100 to 240 VAC, 50-60 Hz, 5.0-7.1A
DC: -48 or -60 VDC, 18A |
Maximum Inrush Current |
100 VAC: 50A peak
240 VAC: 100A peak |
Power Supply Output Voltages |
+5VDC and +12VDC |
Heat Output |
785 BTU/hr (fully populated) |
Altitude |
Operating: To 3000 Meters (9000 feet)
Non-operating: To 12000 Meters (36000 feet) |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Non-operating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Operating: 10% to 90% @ 38° C (100° F), noncondensing
Non-operating: 0% to 90% @ 27° C (80.6° F), noncondensing |
Shock |
Operating: 5.0 g's, 11ms, half-sine (x, y, and
z axis)
Non-operating: 15 g's, 11ms, half sine (x, y and z axis) |
Vibration |
Standalone
Operating: 0.20 g's, 5 Hz to 500 Hz to 5 Hz, swept-sine (5 sweeps in
x, y, and z axis)
Non-operating: 1.0 g's, 5 Hz to 500 Hz to 5 Hz, swept-sine (5 sweeps
in x, y, and z axis)
Rack Mounted
Operating: 0.15 g's vertical and 0.1 g's horizontal, 5 Hz to 500 Hz,
swept-sine
Non-operating: 0.5 g's vertical and 0.25 g's horizontal, 1.0 Octaves
per minute, 5 Hz to 500 Hz, swept-sine |
|
Height |
Desktop: 9.25 cm (3.64 in)
Rackmount: 8.8 cm (3.45 in) |
Width |
Desktop: 48.26 cm (19 in)
Rackmount: 44.45 cm (17.5 in, chassis) |
Depth |
Main Chassis with bezel: 48.36 cm (19.04 in)
Chassis with Power/Fan Modules and bezel: 53.44 cm (21.04 in)
Chassis with Power/Fan Modules, Handles and bezel: 55.98 cm (22.04 in) |
Weight |
No Disks: 14.45 kg (31.85 lb)
12 Disks: 24.15 kg (53.25 lb) |
|
Safety |
IEC 60950 (C22.2-60950) (EN60950) (UL60950) |
EMC and Safety |
Telcordia GR-1089-CORE test report |
Emissions and Immunity |
CISPR22 (EN55022), Class B - European Union FCC Part
15, Class B - USA, Industry of Canada, IEC 61000-3-2:2000 (No Limits) -
European Union, IEC 61000-3-3:1995/A1:2001 (No Limits), CISPR 24 (EN55024;
8kV Contact, 15kV Air) IEC 61000-4-2, CISPR 24 (EN55024, 10V/m) IEC 61000-4-3,
CISPR 24 (EN55024; 1kV I/O, 2kV Power) IEC 61000-4-5, CISPR 24 (EN55024;
1kV I/O, 1kV Power L-L, 2kV Power L-G) IEC 61000-4-5, CISPR 24 (EN55024;
3V I/O and Power) IEC 61000-4-6, CISPR 24 (EN55024) IEC 61000-4-8, CISPR
24 (EN55024; 0v/0.5cycle, 70%V/0.5sec, 0V/5sec), IEC 61000-4-11, Telecordia
GR-63-CORE, Level 3 (No margin requirement) (Telco, - 48VDC Only) GR-1089-CORE,
EN 300 386 |
|
Front |
38 cm (15 in) for service access
15 cm (6 in) for cooling |
Rear |
38 cm (15 in) for service access
15 cm (6 in) for cooling |
Airflow for cooling is from front to rear. |
|
Rack mountable in 19" wide rack |
|
|