Sun StorEdge[tm] 3320, RoHS:YL SCSI Array: Hardware Specifications
|
|
73GB |
Disk drive specifications are:
- 73.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- 73.4GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
|
146GB |
Disk drive specifications are:
- 146GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
- 146GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
|
300GB |
300GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
|
|
Up to 12 Disk drives per array1 |
73GB Disk drives |
12 x 73 = 876GB |
146GB Disk drives |
12 x 146 = 1.752TB |
300GB Disk drives |
12 x 300 = 3.6TB |
Maximum Number of Daisy-chained Arrays |
3 Arrays (maximum capacity):
- 73GB Disk Drives: 12 x 73 = 876GB x 3 arrays = 2.628TB
- 146GB Disk Drives: 12 x 146 = 1.752TB x 3 arrays = 5.256TB
- 300GB Disk Drives: 12 x 300 = 3.6TB x 3 arrays = 10.8TB
|
1Characteristics of the array include:
- The array configuration consists of a 5-drive or 12-drive option.
- Several RAID levels are available: RAID 0, 1, 3, 5, 1+0, 3+0, and 5+0.
- The disk drives are hot-swappable FRUs.
|
|
Power Requirement |
AC: 90 to 264 VAC, 47 to 63
Hz
DC: -36 to 75 VDC |
Input Voltage |
AC: 100 to 240 VAC, single phase
DC: -48 or -60 VDC |
Current Per Input |
AC: 100 VAC (10A), 240 VAC (5A)
DC: -48 or -60 VDC, 18A |
Maximum Inrush Current |
100 VAC: 50A peak
240 VAC: 100A peak |
Power Supply Output Voltages2 |
+5VDC and +12VDC |
Heat Output |
785 BTU/hr (fully populated) |
Altitude |
Operating:
- Standalone Array: 3000 Meters (9000 feet)
- Rack Mounted Array: 3000 Meters (9000 feet)
Non-operating: 12000 Meters (36000 feet) |
Temperature |
Operating:
- Standalone Array: 5° C to 40° C (41° F to 104° F)
- Rack Mounted Array: 5° C to 35° C (41° F to 95° F)
Non-operating: -40° C to 65° C (-40° F to 149° F) |
Humidity |
Operating: 10% to 90% @ 38° C (100° F), noncondensing
Non-operating: 0% to 93% @ 27° C (80.6° F), noncondensing |
Shock |
Operating: 5.0 g's, 11ms, half-sine (x, y, and
z axis)
Non-operating: 15 g's, 11ms, half sine (x, y and z axis) |
Vibration |
Operating:
- Standalone Array: 0.20 g's, 5 Hz to 500 Hz to 5 Hz, swept-sine (5 sweeps in x, y, and z axis)
- Rack Mounted Array: 0.15 g's vertical and 0.1 g's horizontal, 5 Hz to 500 Hz, swept-sine
Non-operating:
- Standalone Array: 1.0 g's, 5 Hz to 500 Hz to 5 Hz, swept-sine (5 sweeps in x, y, and z axis)
- Rack Mounted Array: 0.5 g's vertical and 0.25 g's horizontal, 1.0 Octaves per minute, 5 Hz to 500
Hz, swept-sine
|
2The array configuration uses dual hot-swap, redundant,
load-sharing 420W power supplies (with independent AC inputs). |
|
Height |
Desktop: 9.25 cm (3.64 in)
Rackmount: 8.8 cm (3.45 in) |
Width |
Desktop: 48.26 cm (19 in)
Rackmount: 44.60 cm (17.56 in, chassis) |
Depth |
Main Chassis: 45.72 cm (18 in)
Chassis with Fan Modules: 50.80 cm (20 in)
Chassis with Fan Modules and Handles: 53.34 cm (21 in) |
Weight |
No Disks: 14.45 kg (31.85 lb)
12 Disks: 24.15 kg (53.25 lb) |
|
RoHS Compliance Level |
RoHS:YL |
Safety |
IEC 60950 (C22.2-60950) (EN60950) (UL60950) |
EMC and Safety |
Telcordia GR-1089-CORE test report |
Emissions and Immunity |
They are as follows:
- RF Radiated Emissions:
- CISPR22 (EN55022), Class B - European Union
- FCC Part 15, Class B - USA, Industry of Canada
- Conducted Emissions:
- CISPR22 (EN55022), Class B - European
- FCC Part 15, Class B - USA, Industry of Canada
- Harmonic Emissions: IEC 61000-3-2:2000 (No Limits) - European Union
- Voltage Flicker: IEC 61000-3-3:1995/A1:2001 (No Limits)
- ESD Immunity: CISPR 24 (EN55024; 8kV Contact, 15kV Air) IEC 61000-4-2
- RF Field Immunity: CISPR 24 (EN55024, 10V/m) IEC 61000-4-3
- Electrical Fast Transient/Burst Immunity: CISPR 24 (EN55024; 1kV I/O, 2kV Power) IEC 61000-4-5
- Surge Immunity: CISPR 24 (EN55024; 1kV I/O, 1kV Power L-L, 2kV Power L-G) IEC 61000-4-5
- RF Conducted Immunity: CISPR 24 (EN55024; 3V I/O and Power) IEC 61000-4-6
- Power Frequency Magnetic Field Immunity: CISPR 24 (EN55024) IEC 61000-4-8
- Voltage Dip and Interruption: CISPR 24 (EN55024; 0v/0.5cycle, 70%V/0.5sec, 0V/5sec)
- Voltage Dips/Short Interruptions/Voltage Variation Immunity: IEC 61000-4-11
- NEBS Compliance (Environmental and Physical): Telcordia GR-63-CORE, Level 3 (No margin requirement)
(Telco, -48VDC Only), GR-1089-CORE
- ETSI (Environmental and Emissions): En 300 386
|
|
Front |
38 cm (15 in) for service access
15 cm (6 in) for cooling |
Rear |
38 cm (15 in) for service access
15 cm (6 in) for cooling |
Airflow for cooling is from front to rear. |
|
There are no RoHS compliant rack mount kits3 available at this
time. They will be added here as they become available. In the meantime, to see which non-RoHS compliant
rack mount kits4 are supported, please see the
Sun StorEdge 3320 Release Notes (817-7660).
|
3The Sun StorEdge 3320 SCSI array is rack mountable in a 19"
wide rack.
4Rack-ready configurations of the Sun StorEdge 3320 SCSI
array do NOT come with any rack mount rail kits.
|
|
|