Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 3320, RoHS:YL SCSI Array: Hardware Specifications

73GB Disk drive specifications are:
  • 73.4GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
  • 73.4GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
146GB Disk drive specifications are:
  • 146GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
  • 146GB - 15000 RPM, 1 inch, Ultra 320 LVD Drive
300GB 300GB - 10000 RPM, 1 inch, Ultra 320 LVD Drive
Up to 12 Disk drives per array1
73GB Disk drives 12 x 73 = 876GB
146GB Disk drives 12 x 146 = 1.752TB
300GB Disk drives 12 x 300 = 3.6TB
Maximum Number of Daisy-chained Arrays 3 Arrays (maximum capacity):
  • 73GB Disk Drives: 12 x 73 = 876GB x 3 arrays = 2.628TB
  • 146GB Disk Drives: 12 x 146 = 1.752TB x 3 arrays = 5.256TB
  • 300GB Disk Drives: 12 x 300 = 3.6TB x 3 arrays = 10.8TB
1Characteristics of the array include:
  • The array configuration consists of a 5-drive or 12-drive option.
  • Several RAID levels are available: RAID 0, 1, 3, 5, 1+0, 3+0, and 5+0.
  • The disk drives are hot-swappable FRUs.
Power Requirement AC: 90 to 264 VAC, 47 to 63 Hz
DC: -36 to 75 VDC
Input Voltage AC: 100 to 240 VAC, single phase
DC: -48 or -60 VDC
Current Per Input AC: 100 VAC (10A), 240 VAC (5A)
DC: -48 or -60 VDC, 18A
Maximum Inrush Current 100 VAC: 50A peak
240 VAC: 100A peak
Power Supply Output Voltages2 +5VDC and +12VDC
Heat Output 785 BTU/hr (fully populated)
Altitude Operating:
  • Standalone Array: 3000 Meters (9000 feet)
  • Rack Mounted Array: 3000 Meters (9000 feet)
Non-operating: 12000 Meters (36000 feet)
Temperature Operating:
  • Standalone Array: 5° C to 40° C (41° F to 104° F)
  • Rack Mounted Array: 5° C to 35° C (41° F to 95° F)
Non-operating: -40° C to 65° C (-40° F to 149° F)
Humidity Operating: 10% to 90% @ 38° C (100° F), noncondensing
Non-operating: 0% to 93% @ 27° C (80.6° F), noncondensing
Shock Operating: 5.0 g's, 11ms, half-sine (x, y, and z axis)
Non-operating: 15 g's, 11ms, half sine (x, y and z axis)
Vibration Operating:
  • Standalone Array: 0.20 g's, 5 Hz to 500 Hz to 5 Hz, swept-sine (5 sweeps in x, y, and z axis)
  • Rack Mounted Array: 0.15 g's vertical and 0.1 g's horizontal, 5 Hz to 500 Hz, swept-sine
Non-operating:
  • Standalone Array: 1.0 g's, 5 Hz to 500 Hz to 5 Hz, swept-sine (5 sweeps in x, y, and z axis)
  • Rack Mounted Array: 0.5 g's vertical and 0.25 g's horizontal, 1.0 Octaves per minute, 5 Hz to 500  Hz, swept-sine
2The array configuration uses dual hot-swap, redundant, load-sharing 420W power supplies (with independent AC inputs).
Height Desktop: 9.25 cm (3.64 in)
Rackmount: 8.8 cm (3.45 in)
Width Desktop: 48.26 cm (19 in)
Rackmount: 44.60 cm (17.56 in, chassis)
Depth Main Chassis: 45.72 cm (18 in)
Chassis with Fan Modules: 50.80 cm (20 in)
Chassis with Fan Modules and Handles: 53.34 cm (21 in)
Weight No Disks: 14.45 kg (31.85 lb)
12 Disks: 24.15 kg (53.25 lb)
RoHS Compliance Level RoHS:YL
Safety IEC 60950 (C22.2-60950) (EN60950) (UL60950)
EMC and Safety Telcordia GR-1089-CORE test report
Emissions and Immunity They are as follows:
  • RF Radiated Emissions:
    • CISPR22 (EN55022), Class B - European Union
    • FCC Part 15, Class B - USA, Industry of Canada
  • Conducted Emissions:
    • CISPR22 (EN55022), Class B - European
    • FCC Part 15, Class B - USA, Industry of Canada
  • Harmonic Emissions: IEC 61000-3-2:2000 (No Limits) - European Union
  • Voltage Flicker: IEC 61000-3-3:1995/A1:2001 (No Limits)
  • ESD Immunity: CISPR 24 (EN55024; 8kV Contact, 15kV Air) IEC 61000-4-2
  • RF Field Immunity: CISPR 24 (EN55024, 10V/m) IEC 61000-4-3
  • Electrical Fast Transient/Burst Immunity: CISPR 24 (EN55024; 1kV I/O, 2kV Power) IEC 61000-4-5
  • Surge Immunity: CISPR 24 (EN55024; 1kV I/O, 1kV Power L-L, 2kV Power L-G) IEC 61000-4-5
  • RF Conducted Immunity: CISPR 24 (EN55024; 3V I/O and Power) IEC 61000-4-6
  • Power Frequency Magnetic Field Immunity: CISPR 24 (EN55024) IEC 61000-4-8
  • Voltage Dip and Interruption: CISPR 24 (EN55024; 0v/0.5cycle, 70%V/0.5sec, 0V/5sec)
  • Voltage Dips/Short Interruptions/Voltage Variation Immunity: IEC 61000-4-11
  • NEBS Compliance (Environmental and Physical): Telcordia GR-63-CORE, Level 3 (No margin requirement) (Telco, -48VDC Only), GR-1089-CORE
  • ETSI (Environmental and Emissions): En 300 386
Front 38 cm (15 in) for service access
15 cm (6 in) for cooling
Rear 38 cm (15 in) for service access
15 cm (6 in) for cooling
Airflow for cooling is from front to rear.
There are no RoHS compliant rack mount kits3 available at this time. They will be added here as they become available. In the meantime, to see which non-RoHS compliant rack mount kits4 are supported, please see the Sun StorEdge 3320 Release Notes (817-7660).
3The Sun StorEdge 3320 SCSI array is rack mountable in a 19" wide rack.
4Rack-ready configurations of the Sun StorEdge 3320 SCSI array do NOT come with any rack mount rail kits.

 


  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.