Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 3900/6900: Hardware Specifications

36.4 GB
  • Seagate ST136403FC, 36.4GB - 10000 RPM, FC-AL
  • Seagate ST336704FC, 36.4GB - 10000 RPM, FC-AL
  • Seagate ST336605FC, 36.4GB - 10000 RPM, FC-AL
  • Seagate ST336607FC, 36.4GB - 10000 RPM, FC-AL
  • Fujitsu MAN3367FC, 36.4GB - 10000 RPM, FC-AL
  • IBM DDYF-T36950, 36.4GB - 10000 RPM, FC-AL
  • Seagate ST336752FC, 36.4GB - 15000 RPM, FC-AL
  • Seagate ST336753FC, 36.4GB - 15000 RPM, FC-AL
  • Fujitsu MAS3367FC, 36.4GB - 15000 RPM, FC-AL
73.4 GB
  • Seagate ST173404FC, 73.4GB - 10000 RPM, FC-AL
  • Seagate ST373405FC, 73.4GB - 10000 RPM, FC-AL
  • Seagate ST373307FC, 73.4GB - 10000 RPM, FC-AL
  • Fujitsu MAN3735FC, 73.4GB - 10000 RPM, FC-AL
  • Fujitsu MAP3735FC, 73.4GB - 10000 RPM, FC-AL
  • Hitachi DK32EJ-72FC, 73.4GB - 10000 RPM, FC-AL
181 GB
  • Seagate ST1181677FCV, 181.5GB - 7200 RPM, FC-AL
3900: 655 GB to 29 TB
6900: 655 GB to 26 TB
500MHz, 64-bit UltraSPARC IIe
Minimum 512MB, expandable to 1GB
AC Power 200 - 240 VAC @ 47 to 53 Hz Single phase
Heat Output 3910: ~14000 BTU
3960: ~26000 BTU1
6910: ~14000 BTU
6960: ~26000 BTU1
Temperature Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing s7° C (80.6° F) maximum wet bulb
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: -305 to 3048 meters (-1000 to 10000 feet)
Nonoperating: -305 to 12192 meters (-1000 to 40000 feet)
Shock Operating: 4.0g for maximum duration of 11ms (half-sinewave)
Nonoperating: 10.0g for maximum duration of 11ms (half-sinewave)
Vibration Operating: 5 to 500 Hz @ 0.25g sinusoidal
Nonoperating: 5 to 500 Hz @ 1.0g sinusoidal
1 - 3960 and 6960 values include the Sun StorEdge Expansion Cabinet.
Height 190.5 cm (75 in.)
Width 3910: 60.7 cm (23.9 in.)
3960: 122 cm (47.8 in.)
6910: 60.7 cm (23.9 in.)
6960: 122 cm (47.8 in.)
Depth 94 cm (37 in.)
Weight1 3910: 665 kg (1466 lbs.)
3960: 1295 kg (2855 lbs.)2
6910: 549 kg (1210 lbs.)
6960: 1314 kg (2896 lbs.)2
Power Cord 4.6 m (15 ft.)
1 - Values given are for the maximum hardware configuration available.
2 - 3960 and 6960 values include the Sun StorEdge Expansion Cabinet.
Safety IEC 60950, EN 60950, UL 60950, UL 1950, FCC Part 15 (47CRF15B), CISPR 22 (EN55022 - RF Radiated and Conducted Emissions), IEC 61000-3-2, IEC 61000-3-3
Immunity CISPR 24 (EN55024), IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11
Front With Service Access: 122 cm (48 in.)
Without Service Access: 61cm (24 in.)
Rear With Service Access: 92 cm (36 in.)
Without Service Access: 61 cm (24 in.)
Left1 With Service Access: 92 cm (36 in.)
Without Service Access: 5 cm (2 in.)2
Right1 With Service Access: 92 cm (36 in.)
Without Service Access: 0
1 - Side access may be required for some service procedures. Refer to the documentation that came with the devices.
2 - Sun StorEdge A5x00 disk array, Sun Enterprise 4x00 servers, and some other devices require a clearance of at least two inches for airflow. Unless otherwise stated in the documentation that shipped with your device, no clearance access is required.

 


  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback