Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Storage 7310: Hardware Specifications

Processor
Number 2
Architecture Type: AMD Opteron, Model 2356
Quad Core: 2.3 GHz
Cache memory 4x512KB Level 2
Main Memory
Capacities DIMM slots per CPU Socket: 8
Total DIMM slots: 16
DIMM sizes: 4 GB
DIMM type: DDR2 667 MHz Registered DIMMs (128 bit plus ECC databus)
Maximum capacity: 64 GB (when configured with 4 GB DIMMs and 2 CPU Modules)
Standard Integrated Interfaces
Network Four 10/100/1000Base-T Ethernet ports, RJ-45 connectors
Network Management One dedicated 10/100Base-T Ethernet port, RJ-45 connector
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ-45 Serial Connector
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: one USB 2.0 port
Expansion bus Three internal MD2 low profile 8-lane PCi Express slots (all with x16 mechanical connectors)
Internal Mass Storage
Disks and Capacity Options
  • 2 x 500GB 5400 RPM SATA drives can only be installed in slots 6 and 7 of the 7310. (Used for OS storage and booting)
  • Optional 6 x 100GB Solid State (SSD) SATA drives are supported in slots 0 through 5 of the 7310.
  • Supported J4400 18GB SSD slot allocations: 1 SSD installed in slot 8, 2 SSD's installed in slots 4 and 8, 4 SSD's installed in slots 4, 8, 16, and 20.

  • Drive Type
    Density
    Speed
    Form Factor
    SATA
    500 GB
    5,400 RPM
    2.5"
    SATA
    1 TB
    7,200 RPM
    3.5"
    SATA Solid State (SSD)
    18 GB
    n/a
    3.5"
    SATA Solid State (SSD)
    100 GB
    n/a
    2.5"
    Power Supplies
    Dual redundant, hot swappable power supplies
    (Power Supply Rating DC output = 658W)
    (UL Maximum AC input = 658W x 1.33 efficiency = 875W)
    (8.2 Amps RMS at 100 VAC)
    Software
    Features
  • DTrace Analytics
  • ZFS Hybrid Storage Pool
  • Remote Replication of data for Disaster Recovery
  • Unlimited Read-only and Read-write Snapshots, with Snapshot Schedules
  • Built-in Data Compression
  • Thin Provisioning of iSCSI LUNs
  • Virus Scanning and Quarantine
  • NDMP Backup and Restore
  • Phone-Home of Telemetry for all Software and Hardware Issues
  • Environment
    AC power 100-200 V / 200-240 V AC (50-60 Hz)
    DC Power
    -48 V DC or -60 V DC (10.4 A at -48 V DC, 8.3 A at -60 V DC)
    Temperature Single, non-rack system:
    Operating: 5° C to 35° C (41° F to 95° F)
    Nonoperating: -40° C to 65° C (-40° F to 149° F)
    Humidity Single, non-rack system:
    Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
    Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
    Altitude Single, non-rack system:
    Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
    Nonoperating: up to 12,000 m (40,000 ft.)
    Acoustic noise Single, non-rack system:
    LwAd (1B=10dB)
         6.6 dB at max ambient
    LpAm bystander
         51 dB at max ambient
    Regulations
    Meets or exceeds the following requirements:
    RoHS Compliance Level RoHS:YL
    Safety IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences
    RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
    Immunity EN55024, EN300-386
    Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
    EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
    Dimensions and Weight
    Height 44 mm (1.73 in.)
    Width (not including ears) 425.5 mm (16.75 in.)
    Width (including ears) 443.9 mm (17.47 in.)
    Depth (not including PSU handle) 711.2 mm (28 in.)
    Depth (including PSU handle) 736.4 mm (28.99 in.)
    Weight 18.55 kg (40.90 lb.) maximum assuming PCI-Express card weighs 0.12 kg
    (0.25 lb) each, and without the rack mounting slide rail kit installed.
    Rack Mounting
    Sun Storage 7310 Racks Racks are as follows:
    • Sun Rack 900
    • Sun Rack 1000-38
    • Sun Rack 1000-42
    • Third Party EIA-310-D-1992

      Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
     Feedback