Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Storage 7310 (SAS 2.0): Hardware Specifications

Processor
Number 2
Architecture Type: AMD Opteron
Quad Core: 2.3 GHz or 6-Core: 2.2GHz
Cache memory 4x512KB Level 2
Main Memory
Capacities DIMM slots per CPU Socket: 8
Total DIMM slots: 16
DIMM sizes: 4 GB
DIMM type: DDR2 667 MHz Registered DIMMs (128 bit plus ECC databus)
Maximum capacity: 64 GB (when configured with 4 GB DIMMs and 2 CPU Modules)
Standard Integrated Interfaces
Network Four 10/100/1000Base-T Ethernet ports, RJ-45 connectors
Network Management One dedicated 10/100Base-T Ethernet port, RJ-45 connector
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ-45 Serial Connector
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: one USB 2.0 port
Expansion bus Three internal MD2 low profile 8-lane PCi Express slots (all with x16 mechanical connectors)
Internal Mass Storage
7310 (SAS 2.0) Disks Up to eight 2.5" 500GB 7200 RPM or 500GB 5400 RPM SATA internal hot-swap Disks
Disk Shelf 24x3.5" SAS-2 Disks Up to twenty-four 3.5" 1TB 7200 RPM, 2TB 7200 RPM SAS Disks or 18GB SAS Solid State Drives
Power Supplies
Dual redundant, hot swappable power supplies
(Power Supply Rating DC output = 658W)
(UL Maximum AC input = 658W x 1.33 efficiency = 875W)
(8.2 Amps RMS at 100 VAC)
Software
Features
  • DTrace Analytics
  • ZFS Hybrid Storage Pool
  • Remote Replication of data for Disaster Recovery
  • Unlimited Read-only and Read-write Snapshots, with Snapshot Schedules
  • Built-in Data Compression
  • Thin Provisioning of iSCSI LUNs
  • Virus Scanning and Quarantine
  • NDMP Backup and Restore
  • Phone-Home of Telemetry for all Software and Hardware Issues
  • Environment
    AC power 100-200 V / 200-240 V AC (50-60 Hz)
    DC Power
    -48 V DC or -60 V DC (10.4 A at -48 V DC, 8.3 A at -60 V DC)
    Temperature Single, non-rack system:
    Operating: 5° C to 35° C (41° F to 95° F)
    Nonoperating: -40° C to 65° C (-40° F to 149° F)
    Humidity Single, non-rack system:
    Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
    Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
    Altitude Single, non-rack system:
    Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
    Nonoperating: up to 12,000 m (40,000 ft.)
    Acoustic noise Single, non-rack system:
    LwAd (1B=10dB)
         6.6 dB at max ambient
    LpAm bystander
         51 dB at max ambient
    Regulations
    Meets or exceeds the following requirements:
    RoHS Compliance Level RoHS:YL
    Safety IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences
    RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
    Immunity EN55024, EN300-386
    Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
    EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
    Dimensions and Weight
    Height 44 mm (1.73 in.)
    Width (not including ears) 425.5 mm (16.75 in.)
    Width (including ears) 443.9 mm (17.47 in.)
    Depth (not including PSU handle) 711.2 mm (28 in.)
    Depth (including PSU handle) 736.4 mm (28.99 in.)
    Weight 18.55 kg (40.90 lb.) maximum assuming PCI-Express card weighs 0.12 kg
    (0.25 lb) each, and without the rack mounting slide rail kit installed.
    Rack Mounting
    Sun Storage 7310 (SAS 2.0) and Disk Shelf 24x3.5" SAS-2 Racks Racks are as follows:
    • Sun Rack 900
    • Sun Rack 1000-38
    • Sun Rack 1000-42
    • Third Party EIA-310-D-1992

      Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
     Feedback