Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 9970/9980 Array: Hardware Specifications

Disks (System Capacity)
Number of disk drives (with spares) 9970: 5 to 128
9980: 5 to 1024
Hot spares (maximum) 9970: 4
9980: 16
Individual disk capacities, 3-in form factor 36 GB (15K RPM)
73 GB (10K/15K RPM)
146 GB (10K RPM)
Total raw capacity per system (36 GB drive)

9970: 4.6 TB
9980:
36.8 TB

Total raw capacity per system (73 GB drive) 9970: 9.3 TB
9980: 74.7 TB
Total raw capacity per system (146 GB drive) 9970: 17.5 TB
9980: 147.5 TB
Data Cache
Maximum 9970: 64 GB
9980: 128 GB
Minimum 9970: 2 GB
9980: 4 GB
Increments 9970: 2 GB
9980: 4 GB
Control Memory
Up to 3 GB
Logical Device Support
Up to 8192
Client-Host Interface Processors (CHIP)
Number of CHIP pairs 9970: Up to 3
9980: Up to 4
Simultaneous data transfers per CHIP pair 8
Physical interfaces per CHIP pair 8
Interface speed (fibre channel) 2 GB/sec
Physical Interfaces per System
Maximum (redundant pairs) 9970: 24
9980: 32
Fibre Channel (fiber-optic cable) 9970: 0, 8, 16, or 24
9980: 0, 8, 16, 24, or 32
ESCON 9970: 0, 8, 16, or 24
9980: 0, 8, 16, 24, or 32
FICON 9970: 0, 8, 16, or 24
9980: 0, 8, 16, 24, or 32
Array Control Processor
Number of ACP pairs per system 9970: 1 or 2
9980: Up to 4
Disks per ACP pair 9970: Up to 128
9980: Up to 256
Bandwidth
Per fully configured system
9970: 7.5 GB/sec (5 GB/sec data, 2.5 GB/sec control)
9980: 15 GB/sec (10 GB/sec data, 5 GB/sec control)
Environment
Power 9970: 4.87 kVA
9980 (Control Frame): 2.31 kVA
9980 (Array Frame): 7.16 kVA
Heat 9970: 4.52 kW
9980 (Control Frame): 2.17 kW
9980 (Array Frame): 6.61 kW
Dimensions and Weights
Height 186.0 cm (73.2 in.)
Width (with two side panels) 9970: 78.2 cm (30.77 in.)
9980 (Control Frame): 78.2 cm (30.77 in.)
9980 (Array Frame): 75.0 cm (29.5 In.)
Depth 80.0 cm (31.5 in.)
Weight 9970: 796.0 kg (1752.0 lb.)
9980 (Control Frame): 553.0 kg (1216.6 lb.)
9980 (Array Frame): 755.0 kg (1661.0 lb.)
Power Connectors
System Geography Power Quantity Plug Connector (inline)
9970 US Single-Phase
2
Russell & Stoll 9P53U2
N/A - Controller
Russell & Stoll 9C53U2
N/A - Controller
3-Phase
2
Russell & Stoll 3760DPG or
DDK 115J-AP8508
Russell & Stoll 3934
Europe Single-Phase
2
N/A (Hardwire)
N/A - Controller
N/A (Hardwire)
N/A - Controller
3-Phase
2
N/A (Hardwire) N/A (Hardwire)
9980 DKC (Controller Frame) US Single-Phase
2
Russell & Stoll 9P53U2 Russell & Stoll 9C53U2
3-Phase: 30-Amp
(See FIN I0952-1)
2
Thomas & Betts 3760PDG or DDK 115J-AP8508 Thomas & Betts 3934
3-Phase: 60-Amp
0
N/A – Powered from first Array Frame N/A – Powered from first Array Frame
Europe Single-Phase
2
N/A (Hardwire) N/A (Hardwire)
3-Phase: 30-Amp
(See FIN I0952-1)
0
N/A (Hardwire) N/A (Hardwire)
3-Phase: 60-Amp
0
N/A – Powered from first Array Frame N/A – Powered from first Array Frame
9980 DKU (Disk Array Frame) US Single-Phase
2
Russell & Stoll 9P53U2 Russell & Stoll 9C53U2
3-Phase: 30-Amp
(See FIN I0952-1)
2
Thomas & Betts 3760PDG or DDK 115J-AP8508 Thomas & Betts 3934
3-Phase: 60-Amp
2
Russell & Stoll RS460P9W Russell & Stoll RS460C9W or
Hubbell HBL460C9W or
Leviton 460C9W
Europe Single-Phase
2
N/A (Hardwire) N/A (Hardwire)
3-Phase: 30-Amp
(See FIN I0952-1)
2
N/A (Hardwire) N/A (Hardwire)
3-Phase: 60-Amp
2
N/A (Hardwire) N/A (Hardwire)
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback