Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun StorEdge[tm] 9985 System: Hardware Specifications

Number of disk drives (with spares) Up to 120
Hot spares (maximum) 16
Individual disk capacities 73GB (15K RPM)
146GB (10K RPM)
300GB (10K RPM)
Total raw capacity per system (73GB drive) 8.76TB (120 disk drives x 73GB = 8.76TB)
Total raw capacity per system (146GB drive) 17.52TB (120 disk drives x 146GB = 17.52TB)
Total raw capacity per system (300GB drive) 36TB (120 disk drives x 300GB = 36TB)
Supported RAID Levels RAID 1, RAID 5, RAID 6
Maximum 64GB
Minimum 4GB
Increments 2GB
Maximum 6GB
Minimum 2GB
Maximum of 1
Up to 16,384
Front End Director (FED) Ports 16 FC
Back End Director (BED) Ports 8 FC
1The "mixed adapter" is new and unique to the Sun StorEdge 9985 system; the mixed adapter is a combination of FED and BED. This adapter can only be used in slots 1A and 2F.
Number of Slots 2
Designated Slots 1B and 2E
2The "optional slots" are for multi-purpose use. These slots can accommodate FED (CHA), NAS Blade (CHN), and mainframe adapters such as, FICON and ESCON.
Fibre Channel (fiber-optic cable) 16-48 2Gb FC Host Ports
ESCON Up to 16 Host Ports
FICON Up to 8 Host Ports
NAS Up to 8 1Gb NAS Ports
Bandwidth
Aggregate System
12GB/sec
Maximum System Data
8.5GB/sec
Maximum System Control
3.5GB/sec
Temperature Operating: 16° to 32° C (60.8° to 89.6° F)
Non-operation: -10° to 43° C (14° to 109.4° F)
Shipping & Storage: -25° to 60° C (-13° to 140° F)
Relative Humidity Operating: 20% to 80%
Non-operation: 8% to 90%
Shipping & Storage: 5% to 95%
Maximum Wet Bulb Operating: 26° C (78.8° F)
Non-operation: 27° C (80.6° F)
Shipping & Storage: 29° C (84.2° F)
Temperature Deviation Per Hour Operating: 10° C (50° F)
Non-operation: 10° C (50° F)
Shipping & Storage: 20° C (68° F)
Acoustic Level Operating: 65 dB
Non-operation: n/a
Shipping & Storage: n/a
Height Control Array Frame (DKC515I-5/5R): 703 mm (27.7 in.)4
Array Frame (DKC-F515I-B2R): 522 mm (20.6 in.)
Width Control Array Frame (DKC515I-5/5R): 480 mm (18.9 in.)
Array Frame (DKC-F515I-B2R): 480 mm (18.9 in.)
Depth Control Array Frame (DKC515I-5/5R): 648 mm (25.5 in.)
Array Frame (DKC-F515I-B2R): 648 mm (25.5 in.)
Weight5 Control Array Frame (DKC515I-5/5R): 82 kg (180.8 lb.)
Array Frame (DKC-F515I-B2R): 66 kg (145.5 lb.)
3Allow 596 mm (23.47 in.) in the rear of the unit for service clearance.
4This dimension includes the thickness of the SVP 43.2 mm (1.7 in.).
5Refer to the Sun StorEdge 9985 Array documentation for a list of all component weights within the system.
Geography Frequency Input Voltages (AC) Conditions(%) Tolerance (%)
US 60Hz (+ or - 0.5Hz) 200V, 208V, or 230V 1 Phase (2 Wire + Ground) +6% or -8%
Europe 50Hz (+ or - 0.5Hz) 200V, 220V, 230V, or 240V 1 Phase (2 Wire + Ground) +6% or -8%
6Circuit breaker rating for the control array frame is 30A.
Power Supply Modules Battery Backup Modules
Maximum of 27 Maximum of 27
7Two power supply modules and two battery backup modules are used for redundancy.
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.