Processor
|
Number |
4, 8, or 12 |
Architecture |
UltraSPARC[tm] III Cu: 1.2GHz
UltraSPARC IV: 1.05GHz, 1200MHz or 1350MHz, superscalar SPARC V9, ECC protected
UltraSPARC IV+: 1.5GHz or 1.8GHz
|
Cache per processor |
Primary (L1): Parity protected 32KB instruction and 64KB data on chip
(single-bit errors are corrected)
Secondary (L2): ECC-protected 16-MB external cache on UltraSPARC IV.
Level 3 cache per UltraSPARC IV+ processor: 32 MB shared external.
|
System Interconnect |
9.6 GB/sec Sun Fireplane interconnect.
System bus with redundant data, address and response crossbar interconnect
|
System |
CPU/Memory Boards |
Maximum of 3 CPU/Memory boards, with four processors each, and up to
64GB memory per board; maximum 12 processors per system |
Bandwidth |
9.6 GB/sec sustained bandwidth
31.2 GB/sec aggregate bandwidth |
Main Memory |
Maximum 64GB memory per 4 CPUs on a CPU/Memory board,
up to 192GB maximum system memory capacity |
Standard Interfaces |
Alarm |
One alarm port (DB15) |
Ethernet |
One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair port
(RJ-45) - Used for LOM/System Controller
Two 10/100/1000BASE-T Ethernet (copper) ports
|
PCI |
PCI Assembly: Six PCI slots via three buses. One 3.3V, 32/64-bit, 66MHz slot, Five 5V, 32/64-bit, 33MHz slots.
PCI+ Assembly: Six PCI slots via three buses. Six 3.3V, 32/64-bit, 66MHz slots.
PCI-X Assembly: Six PCI-X slots. 64-bit, 100MHz, 3.3V, (Integrated Ultra-320 SCSI controller)
Note:All (6) slots are short slots and cannot support long PCI cards.
|
Serial |
One RS-232/RS-423 asynchronous/synchronous serial port (RJ45), Serial A
(Serial B is reserved)
|
SCSI |
One Ultra3 SCSI 68-pin SCSI port
Single-ended (40MB/sec) or
LVD (160MB/sec)
|
Internal Mass Storage |
Disks |
Two 73GB Ultra3-SCSI internal disks, 1.0 in., 10,000 RPM, or
two 146GB Ultra-320 SCSI internal disks, 1.0 in., 10,000 RPM |
DVD-ROM |
DVD-ROM internal drive |
Tape |
DDS-4 or DAT72 tape drive (optional) |
Power Supplies |
Four power supplies providing 2N hot-pluggable redundancy;
only two are required for the system to run. |
Environment |
AC input |
200-240V single phase AC, 47-63Hz, with two 11/13 Amp circuits
redundant with another two on a separate grid |
Input power |
3300W maximum |
Heat output |
Base Configuration: 5250.64 BTU/hr
Maximum Configuration: 12683.38 BTU/hr
|
Temperature (operating) |
Optimal: 22° C (72° F)
Range: 5° C to 40° C (41° F to 104° F)
|
Humidity (operating) |
Optimal: 45% non-condensing
Range: 10% to 90% non-condensing humidity |
Altitude |
Up to 3,048 meters (10,000 ft) |
Regulations
Meets or exceeds the following requirements:
|
RoHS Compliance Level |
RoHS:YL
|
Safety |
USA: UL 60950 3rd Edition
Canada: CAN/CSA C22.2 No. 60950-00
Europe: EN 60950 3rd Edition
Argentina: S Mark
Russia:Gost-R
CB Scheme with all national deviations |
Emissions |
USA: FCC Class A
Canada: ICES-003 Class A
Europe: EN55022 Class A, EN6100-3-2/3-3
Japan: VCCI Class A
Taiwan: CNS-13438 BSMI
Australia: AS/NZ 3548 (C-tick)
Russia: Gost-R |
Immunity |
All European requirements:
EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11, and EN300-386 |
Regulatory markings |
CE, FCC, ICES-003, C-tick, VCCI, Gost-R
BSMI, UL/cUL/S Mark, TUV-GS, MIC |
Dimensions and Weights |
Height |
Chassis Only: 21.00 in (53.34 cm) / 12U
With Mounting Cradle: 25.30 in (64.21 cm)
With Wooden Pallet: 36.97 in (93.90 cm) |
Width |
Chassis Only: 17.50 in (44.50 cm)
With Mounting Cradle: 22.20 in (56.48 cm)
With Wooden Pallet: 23.62 in (60.00 cm)
|
Depth |
System Only: 22.00 in (55.80 cm)
Including Slides: 22.40 in (56.80 cm)
With Mounting Cradle: 22.00 in (55.82 cm)
With Wooden Pallet: 27.76 in (70350 cm)
|
Weight |
System Only: 236.0 lbs (107 kg)
With Mounting Cradle: 286.0 lbs (130 kg)
With Cable Mgmt & Slides: 310.0 lbs (141 kg) |
Clearance and Service Access |
Front |
35 in (86cm) |
Rear |
35 in (86cm) |
Refer to the Sun Fire
E2900 Site Planning Guide (817-4052) for clearance and service access details. |
Racking |
All Sun racks and most third party; 24 in. (600mm) and deeper racks;
2 per 4-post rack, 1 per 2-post rack |