Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] E4900, RoHS:YL Server: Hardware Specifications

Processor
Number 4 to 12
Architecture UltraSPARC[tm] III Cu: 1200MHz
UltraSPARC IV: 1050MHz or 1350MHz, superscalar SPARC V9, ECC protected
UltraSPARC IV+: 1.5GHz or 1.8GHz superscalar SPARC V9, ECC protected
Cache per processor UltraSPARC IV:
Primary (L1): 64 KB 4-way data, 32 KB 4-way instruction, 2 KB Write, 2 KB Prefetch
Secondary (L2): 16 MB external (exclusive access to 8 MB per pipeline), On-chip controller and address tags
UltraSPARC IV+:
Primary (L2): 2 MB on-chip
Secondary (L3): 32 MB off-chip
System Interconnect 9.6-GB/sec. Sun Fireplane interconnect. System bus with redundant data, address, and response crossbar interconnect.
System Boards
Number of boards Up to 3
CPU/Memory board 4 CPUs with up to 64GB per board; maximum 12 processors per system.
PCI I/O Assembly
PCI-X I/O Assembly
PCI+ I/O Assembly
Up to 16 × PCI slots (12 at 33MHz and 4 at 33 or 66MHz)
Up to 16 × 64 bit PCI slots (12 at 33, 66 or 100MHz and 4 at 33MHz)
Up to 16 × 32 or 64 bit PCI slots (12 at 33 or 66MHz and 4 at 33MHz)
Main Memory

64 GB memory (max) per 4 CPUs on a CPU/Memory board, Up to 192 GB per domain

Maximum system memory capacity of 192 GB (3 × 64GB)

Standard Interfaces
System Controller Responsible for the overall control of the system. Each System Controller includes one RS-232/423 (DB25) serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45) interface. Two per system.
Power Supplies
3 Fault-tolerant, redundant, hot swappable, and hot pluggable power supplies
Environment
AC input 200-240 VAC, 47-63 Hz, 16 A(per power cord)
Input power 4180W @ 220V
Heat output 14,260 BTUs/hr
Temperature Operating: 5° C to 35° C (41° F to 95° F) - derate 2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 0 to 3,000 meters (0 to 10,000 feet)
Nonoperating: 0 to 12,000 meters (0 to 40,000 feet)
Acoustic noise 69 dB(A)
Vibration Operating: 0.15 G's, 5 to 500Hz, swept-sine
Nonoperating: 1.5mm single amplitude/0.6 G's, 5 to 500Hz, swept-sine, vertical 0.75mm single amplitude/0.3 G's, 5 to 500Hz, swept-sine, horizontal
Shock 3 G's, 11 ms, half-sine
Number of cords 3 (length each - 4.6 meter, 15.0 ft)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL 60950, third-edition USA CAN/CSA-C22.2 No. 60950-00, Canada EN 60950, third-edition, Europe S Mark, Argentina Gost-R, Russia CB Scheme with all national deviations
Emissions EN55022 Class A, Europe EN6100-3-2 / 3-3, Europe FCC Class A, USA ICES-003 Class A, Canada VCCI Class A, Japan CNS 13438, (BSMI-Taiwan) AS/NZ 3548 (C-tick), Australia Gost-R, Russia
Immunity All European requirements EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, and EN300-386
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, Gost-R BSMI, UL/cUL/S Mark, TUV-GS, MIC
Dimensions and Weights
Height Deskside: 82.3 cm (32.4 in)
Rackmount: 76.2 cm (30.0 in)
Width  Deskside: 48.1 cm (18.9 in)
Rackmount: 44.6 cm (17.56 in)
Depth  Deskside: 86.9 cm (34.2 in)
Rackmount: 72.4 cm (28.5 in)
Weight  Deskside: 131.1 kg (289.0 lb)
Rackmount: 131.1 kg (289.0 lb)
Clearance and Service Access
Front 122 cm (48 in)
Rear 91.4 cm (36 in)
Right 0 clearance during operation
Left 0 clearance during operation
Rack
Sun Fire Rack for Sun Fire E4900, SFE-XCAB

   
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback