Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] E6900 Server: Hardware Specifications

Processor
Number 4 to 24
Architecture UltraSPARC[tm] III Cu: 900MHz, 1050MHz, or 1200MHz
UltraSPARC IV: 1050MHz, 1200MHz, or 1350MHz, superscalar SPARC V9, ECC protected
UltraSPARC IV+: 1.5GHz or 1.8GHz superscalar SPARC V9, ECC protected
Cache per processor UltraSPARC IV:
Primary (L1): 64 KB 4-way data, 32 KB 4-way instruction, 2 KB Write, 2 KB Prefetch
Secondary (L2): 16 MB external (exclusive access to 8 MB per pipeline), On-chip controller and address tags
UltraSPARC IV+:
Primary (L2): 2 MB on-chip
Secondary (L3): 32 MB off-chip
System Interconnect 9.6-GB/sec. Sun Fireplane interconnect. System bus with redundant data, address, and response crossbar interconnect.
System Boards
Number of boards Up to 6
CPU/Memory board 4 CPUs with up to 64GB per board; maximum 24 processors per system.
PCI I/O Assembly
PCI-X I/O Assembly
Up to 32 × PCI slots (8 × 66 MHz and 24 × 33 MHz)
Up to 32 × 64-bit PCI-X slots (24 × 100 MHz and 8 × 33MHz)
Main Memory
64 GB memory (max) per 4 CPUs on a CPU/Memory board, Up to 384 GB per domain

Maximum system memory capacity of 384 GB (6 × 64GB)
Standard Interfaces
System Controller Responsible for the overall control of the system. Each System Controller includes one RS-232/423 (DB25) serial interface and one 10/100BASE-T ethernet/fast ethernet (RJ45) interface. Two per system.
Internal Mass Storage
Sun StorEdge[tm] D240 Media Tray
Sun StorEdge S1 Array
Power Supplies
6 Fault-tolerant, redundant, hot swappable, and hot pluggable power supplies
Environment
AC power 200-240 VAC, 47-63 Hz, 32 A(per power cord)
Input power 9,120 W @ 220V
Heat output 31,113 BTU/hr
Temperature Operating: 5° C to 35° C (41° F to 95° F) - derate 2° C for every 1 km up to 3 km
Nonoperating: -20° C to 60° C (-4° F to 140° F)
Humidity Operating: 20% to 80% relative humidity, noncondensing
Nonoperating: 5% to 93% relative humidity, noncondensing
Altitude Operating: 0 to 3,000 meters (0 to 10,000 feet)
Nonoperating: 0 to 12,000 meters (0 to 40,000 feet)
Acoustic noise 69 dB(A)
Vibration Operating: 0.15 G's, 5 to 500Hz, swept-sine
Nonoperating: 1.5mm single amplitude/0.6 G's, 5 to 500Hz, swept-sine, vertical 0.75mm single amplitude/0.3 G's, 5 to 500Hz, swept-sine, horizontal
Shock 3 G's, 11 ms, half-sine
Number of cords 4
Regulations
Meets or exceeds the following requirements:
Safety UL 60950, third-edition USA CAN/CSA-C22.2 No. 60950-00, Canada EN 60950, third-edition, Europe S Mark, Argentina Gost-R, Russia CB Scheme with all national deviations
Emissions EN55022 Class A, Europe EN6100-3-2 / 3-3, Europe FCC Class A, USA ICES-003 Class A, Canada VCCI Class A, Japan CNS 13438, (BSMI-Taiwan) AS/NZ 3548 (C-tick), Australia Gost-R, Russia
Immunity All European requirements EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, and EN300-386
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, Gost-R BSMI, UL/cUL/S Mark, TUV-GS, MIC
Dimensions and Weights
Height 190.5 cm (75 in)
Width 61 cm (24 in)
Depth 134.6 cm (53 in)
Weight, main cabinet 544.3 kg (1200 lbs)
Power Cord (15 ft), (4.6 m)
Clearance and Service Access
Front 122 cm (48 in)
Rear 91.4 cm (36 in)
Right 0 clearance during operation*
Left 0 clearance during operation*
* To access and remove side panels, allow approximately 2 ft (60 cm.) of space on the sides. For any peripheral tray in the processor cabinet OVER 508 mm (20 in) in length, allow additional space for access to the doors on the side where the peripheral will be loaded.
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback