Sun Storage J4200, RoHS:YL Array: Hardware Specifications
|
|
Disk Configuration |
Sun Storage J4200, RoHS:YL Array |
Up to twelve disk drives as follows:
- 73GB 15000 RPM, 3 Gb/sec SAS
- 146GB 15000 RPM, 3 Gb/sec SAS
- 300GB 15000 RPM, 3 Gb/sec SAS
- 400GB 10000 RPM, 3 Gb/sec SAS
- 250GB 7200 RPM SATA
- 500GB 7200 RPM SATA
- 750GB 7500 RPM SATA
- 1TB 7200 RPM SATA
- 2TB 7200 RPM SATA
|
|
|
Supported drives/system per tray capacity:raw, unformatted |
73GB SAS Disk drives |
12 × 73GB = 876GB |
146GB SAS Disk drives |
12 × 146GB = 1.75TB |
300GB SAS Disk drives |
12 × 300GB = 3.6TB |
400GB SAS Disk drives |
12 × 400GB = 4.8TB |
250GB SATA Disk drives |
12 × 250GB = 3.0TB |
500GB SATA Disk drives |
12 × 500GB = 6.0TB |
750GB SATA Disk drives |
12 × 750GB = 9TB |
1TB SATA Disk Drives |
12 × 1TB = 12.0TB |
2TB SATA Disk Drives |
12 × 2TB = 24.0TB |
Drive Specifications |
Form factor: 3.5 in., low-profile
Interface: Dual-ported SAS |
Interfaces |
Host interfaces/link speeds |
Two 3 Gb/s "x4 wide" SAS host interfaces
|
Other interfaces |
SAS/SATA drive support |
Serial |
Up to two RS-232 Serial Mgt ports |
|
Heat Dissipation
|
344.47 BTU/hr. |
AC Power |
500 watts (+5V @ 19A/+12V @ 35A) |
Input Voltage
|
88 -264VAC |
Power Consumption
|
106.54 VA, 100.4 W |
Operating Temperature |
0° C to 35° C (32°
F to 95° F) |
Operating Relative Humidity |
20% to 95% relative humidity, noncondensing
|
Operating Altitude |
-50 to 10,000 feet |
Shock |
31 Gs, 2.6msec, half-sine wave pulse
|
Vibration |
0.25Gs @ 3 Hz to 200Hz
|
|
Height |
87.4 mm (3.44 in) |
Width |
445 mm (17.52 in) |
Depth |
619.39 mm (24.39 in) including bezel and SAS connector
610.4 mm (24.03 in) including bezel and power supply handles |
Weight (maximum) |
28 kg (61.73 lb) with 12 disks
|
|
Note: Meets or exceeds the following
requirements. |
Safety and Emissions |
FCC Class A, CE, VCCI, CCC, BSMI: Taiwan/CNS/3438, C-Tick,
UL/CUL, UL60950-1, TVU, EN60950-1, IEC60950-1 |
|
Sun 72-Inch StorEdge Expansion Cabinet, Sun Rack 900/1000 Cabinet, Sun Fire Expansion Cabinet |
Clearance and Service Access
|
Front |
25 cm (9.84 in) for cooling
|
Rear |
35 cm (13.78 in) for cooling
|
Top |
20 cm (7.87 in) for cooling
|
Availability, Reliability, and Serviceability
|
No single point of failure due to redundant controllers
Non-disruptive firmware upgrades
Non-disruptive component (major CRU) replacement
Non-disruptive hot-swappable controllers
Non-disruptive hot-swappable disk drives
Dual hot-swappable, redundant, and load-sharing power supplies |
|
|