Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Netra[tm] 1290 Server, RoHS:YL: Hardware Specifications

Processor
Number 4, 8, or 12
Architecture UltraSPARC IV+ 1.5GHz
Cache per processor L2: 2MB (int)
L3:
32MB (ext)
System Interconnect 9.6 GB/s Sun Fireplane interconnect
System Boards
Number of boards Maximum of 3 CPU/Memory boards
CPU/Memory board Four processors each and up to 64 GB memory per board; maximum 12 processors per server
Main Memory
16GB to 192GB
Standard Interfaces
Alarm
  • One alarm port (DB15)
Ethernet
  • Two 10/100/1000 Base-T ports
  • One 10/100 Base-T port (LOM)
PCI+

 

  • 6× 3.3V, 32/64-bit, 66MHz short PCI+ slots
Serial
  • Two RS-232C/RS-432C ports (RJ-45) Serial A & B
  • Serial B is reserved
SCSI

 

  • One Ultra320 SCSI multimode (SE/LVD)
Internal Mass Storage
Disks Two hot-swappable 146GB 15,000 RPM internal disks
DVD-ROM DVD-ROM Writer / CD-ROM Writer internal drive, DVD-ROM drive
Tape DAT72 (optional)
Power Supplies
DC: 4x -48 V/-60 V DC Power Supply Units - 2 are required at any one time, providing 2N redundancy
AC: 4x 200-240 V AC Power Supply Units - 2 are required at any one time, providing 2N redundancy
Environment
Voltage DC: -48VDC / -60VDC
AC: 200-240 VAC single phase
Input power DC: 3980W Maximum input power / 1990W input per PSU. 1500 W output per PSU. But only two can draw this or otherwise >2 PS share the input power load.
AC: 3600W Maximum input power / 1500W output @ 200 - 240 V AC per supply. But only two can draw this or otherwise >2 PS share the input power load. Frequency: 47 - 63 Hz
Power Consumption 4 Processors, 16GB memory: 1600W
12 Processors, 96GB memory: 3360W
Heat output Base System including:
  • 4× 1.5GHZ CPUs
  • 16GB memory
  • 2× 146GB Disks
  • 6× PCI cards
5950 BTU/Hr.
Medium system, including:
  • 8× 1.5GHZ CPUs
  • 32GB memory
  • 2× 146GB Disks
  • 6× PCI cards
7950 BTU/hr
Large system, including:
  • 12× 1.5GHZ CPUs
  • 48GB memory
  • 2× 146GB Disks
  • 6× PCI cards
9950 BTU/hr
Loaded system, including:
  • 12× 1.5GHZ CPUs
  • 96GB memory
  • 2× 146GB Disks
  • 6× PCI cards
11,500 BTU/Hr.
Temperature Short Term Operating: -5° C to 55° C (23° F to 131°F)
Standard Operating:
5° C to 35° C (41° F to 95°F)
Non-operating: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 85% non-condensing
Altitude Operating: Maximum 3000 meters (9840 ft)
Non-Operating: Maximum 12000 meters (39370 ft)
Acoustic noise 73 dB(A)
Regulations
Meets or exceeds the following requirements:
Safety

North America: UL 60950 3rd edition, CSA C22.2 No 60950-00 3rd edition (Certified: UL + UL for Canada)
European Community: EN 60950:2000, (Certified: UL for Germany/GS-Mark + GOST R for Russia)
Worldwide except North America: IEC 60950:1999 + CB Bulletin (Certified: DEMKO + UL for Argentina/IRAM S-Mark)

RFI/EMI Class A: Australia/New Zealand AS/NZ 3548, Industry Canada ICES-003, European Community EN55022/CISPR22, Japan VCCI, Taiwan CNS 13438, and US FCC 47CFR15.B.
Emissions EN55022 Class A, Europe EN6100-3- 2/3-3, Europe FCC Class A, USA ICES-003 Class A, Canada VCCI Class A, Japan CNS-13438, (BSMI-Taiwan) AS/NZ 3548 (C-tick), Australia Gost-R, Russia
Environmental Telcordia SR-3580, NEBS Level 3
Immunity EN55024, i.e. EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, and EN61000-4-11
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, Gost-R, BSMI, UL/cUL/S Mark, TUV-GS, MIC
Dimensions and Weights
Height With Slides: 527mm (20.75 in)
With Cradle: 642.1mm (25.3 in)
Width  With Slides: 445mm (17.5 in)
With Cradle: 564.8mm (22.2 in)
Depth 

With Slides: 558mm (22 in)
With Cradle: 558.2mm (22 in)

Weight  Minimum: 110kg (242 lb)
Maximum: 132kg (290 lb)
Clearance and Service Access
Front n/a
Rear n/a
Racking
Recommended rack for Netra 1290 is the Sun Rack 900.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback