Racking |
Supports all Sun Racks. Fits into a standard 19-inch wide rack. Rack kit included - 19 inch 4 post slide and 2 post hard mount.
Additional rack kits available -24-inch 4 post slide and 2 post hard mount kit
|
Processor |
Number |
One or two 1.3 GHz UltraSPARC IIIi processors |
Architecture |
64-bit, 4-way Superscalar SPARC V9
|
Cache memory |
64 KB data, 32 KB instructions and 1 MB integrated L2
|
Main
Memory |
Capacities |
- 4 DIMM slots per processor, DDR PC2100 or faster registered ECC
- System configurations from 1 GB to 8 GB
|
Standard
Interfaces |
Alarms |
Four fail-safe, dry contact alarms (critical, major, minor and user) |
Ethernet |
- Four 10/100/1000Base-T Ethernet ports
- One 10Base-T Ethernet port
|
Expansion bus |
- One PCI 2.2 compliant expansion slot:
- full-length 64-bit 33/66 MHz 3.3V
|
SCSI |
One Ultra160SCSI multimode (SE/LVD) |
Security |
Optional Sun Crypto Accelerator 500 card offering security protocol acceleration via a
daughter card |
Serial |
- One TIA/EIA-232-F asynchronous (DB9) Port
- One TIA/EIA-232-F (RJ45) Port (Serial Management)
|
System Configuration Reader and Card (removable) |
Front accessible for transfer of system configuration information, including
host ID, MAC address, NVRAM
|
USB |
Two OHCI-1.0 Compliant Interfaces, supporting dual speeds of 12 and 1.5
Mbits/sec each |
Internal
Mass Storage |
Disks |
Up to two hot-swap 73-GB 10K rpm SAS disk drives |
DVD-ROM |
- Optional slim-line ATAPI DVD-ROM
- Optional slim-line DVD-RW
|
External Disk |
- Sun StorEdge 9990 series (9910, 9960) via HBA's x6727A / SG-XPCI1FC-
Sun StorEdge S1 array*
- Sun StorEdge T3B array
- Sun StorEdge 3310 SCSI array*
- Sun Storedge 3120 SCSI Array*
- Sun StorEdge 3510 FCAL array
- Sun StorEdge 9990 series (9970, 9980) via HBA's x6727A / SG-XPCI1FC-JF2 (F-port) /
SG-XPCI2FC-JF2 (F-port)
- Sun StorEdge D240 Media Tray
|
External Tape |
- Sun StorEdge DAT 72 Tape*
- Sun StorEdge L8 Tape Autoloader (Solaris 8 & 9, LT02 & SDLT320)
- Sun StorEdge L25 via X6758A HBA (Solaris 9 only, LT02)
- Sun StorEdge L100 via X6758A HBA (Solaris 9 only, LT02)
|
Environment |
Power Supplies
(DC Version) |
One power supply (DC) included.
Typical system input power:200 to 300 watts depending on configuration.
Max. input power:400W (-40VDC @ 10A)
Max. output power:320W
Max. power consumption: 1365 BTU/hr
Typical Power consumption: 1025 BTU/hr
Input current:N/A
Power inputs:Dual DC power inputs.
|
DC Power |
-40V to -75V DC (range), single or dual power source
-48V or -60V DC (nominal) |
Heat output |
1,241 BTU/hr
|
Temperature |
Operating: (DC) -5°C to 40°C (41°F to 104°F)
Nonoperating: -40°C to 70°C (-40°F to 158°F)
|
Humidity |
Operating: (DC) 5% to 90% relative humidity, noncondensing, but not
exceeding 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lb. dry air)
Nonoperating: up to 93% relative humidity, noncondensing, 38°C
(100.4°F) max wet bulb |
Altitude |
Operating:-400m to 3000m (-1300 ft to 9850 ft)
Nonoperating:-400 to 12,000m (-1300 ft to 39000 ft) |
Acoustic noise |
Declared Noise emissions in accordance with ISO 9296:
Operating: 7.0 B ( LWAd(1B=10dB))
Idling: 7.0 B (LWAd(1B=10dB))
|
ETSI |
EN 300 019-2-1,2,3, Class 1.2, 2.3, 3.1E
- Except -5°C cold start
- Except condensing humidity
- Except rain
|
Seismic |
GR-63-CORE requirements for earthquake zone 4 |
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL |
Certification |
Safety: cULus, TUV GS, CB Scheme with all National Differences; CE, CCC, GOST R, S-Mark
EMC: Class A - FCC, CE, VCCI, BSMI, C-Tick, MIC, CCC, GOST
Telecommunication: Telcordia SR 3580 NEBS Level 3 |
Dimensions
and Weights |
Height |
43.6 mm (1.7 in.) |
Width |
425 mm (16.3 in.) not including bezel
442mm (17.4-inch) including bezel |
Depth |
483mm (19-inch) to rear connectors
|
Weight |
9.8kg (21.6 lbs) - Fully configured with DVD and rack kit, Not including PCI card |