| Processor |
| Number |
One UltraSPARC T2 multicore processor |
| Architecture |
SPARC V9 architecture, ECC protected |
| CPUs |
1.2GHz 4-Core
1.2GHz 6-Core
1.2GHz 8-Core |
| Cache memory |
4MB Level 2 |
| Main Memory |
| Capacities |
Total DIMM slots: 16
DIMM type: FBDIMM
DIMM size: 1GB, 2GB, or 4GB
Maximum capacity: 64GB (16 × 4GB) maximum, 4GB (4 × 1GB)
minimum
|
| Standard Integrated Interfaces
|
| Network |
4 × 10/100/1000 Mbps ports |
| Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
| Serial Management |
One dedicated RJ-45 port |
| Serial |
One DB-9 connector |
| Alarm |
Four programmable dry contact alarms (critical, major, minor, and user) |
| USB |
Rear: 2 USB 2.0 Ports |
| PCI Expansion Slots |
6 slots:
1 PCI-X full height, full length, 133MHz slot
1 PCI-X full height, half length, 133MHz slot
1 PCI-Express full height, full length x8 electrical/x16 physical slot
1 PCI-Express low profile x8 electrical/x8 physical slot
2 PCI-Express/XAUI low profile x4 electrical/x8 physical slots |
| Internal Mass Storage |
| Disks |
Up to 4 300GB SAS 2.5 inch form factor disk drives |
| DVD-ROM |
1 slimline DVD-Writer/CD-Writer |
| Power Supplies |
| Two hot-swappable power supplies(AC/DC) providing N + 1 redundancy |
| Environment |
| Input Voltage |
DC: -48 VDC or -60 VDC nominal
AC: 100-240 V AC, 50-60 Hz |
| Input Current - Total |
DC: 19 A maximum total for all inputs at -48 VDC
AC: 6 A maximum total for all inputs at 100-120 VAC |
| Output Power |
660 Watts maximum, using one power supply |
| Heat Output |
1365 BTU/hr (1440 KJ/hr) |
| Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Short Term: -5° C to 55° C (23° F to 131° F)
|
| Humidity |
Operating: 10% to 90% relative humidity noncondensing, short term,
-5°C to 55°C (80.6° F) wet bulb
Short Term: 5% to 90%, non-condensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lb. dry air)
Nonoperating: 93% relative humidity noncondensing, 37.7° C (100.4°
F) wet bulb |
Regulations
Meets or exceeds the following requirements: |
| RoHS Compliance Level |
RoHS:Y |
| NEBS |
Level 3 Compliant |
| Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations,
IEC825-1,2 CFR21 part 1040, CNS14336, GB4943 |
| Ergonomics |
EK1-ITB-2000 |
| RFI/EMI |
EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548
Class A CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2,
GB17625.1, EN61000-3-3 |
| Immunity |
EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC
61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
| Telecommunications |
EN 300-386, IEC 60068 |
| Dimensions and Weight |
| Height |
87.4 mm (3.44 in.) |
| Width |
442 mm (17.4 in.) |
| Depth |
525 mm (20.67 in.) |
| Weight |
17.5 kg (38.5 lb.) |
| Clearance
and Service Access |
| Front |
910 mm (36 in.) |
| Rear |
910 mm (36 in.) |
| Rack Mounting |
| TBD |