Processor |
Number |
One UltraSPARC T2 multicore processor |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
1.2GHz 4-Core
1.2GHz 6-Core
1.2GHz 8-Core |
Cache memory |
4MB Level 2 |
Main Memory |
Capacities |
Total DIMM slots: 16
DIMM type: FBDIMM
DIMM size: 1GB, 2GB, or 4GB
Maximum capacity: 64GB (16 × 4GB) maximum, 4GB (4 × 1GB)
minimum
|
Standard Integrated Interfaces
|
Network |
4 × 10/100/1000 Mbps ports |
Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Serial |
One DB-9 connector |
Alarm |
Four programmable dry contact alarms (critical, major, minor, and user) |
USB |
Rear: 2 USB 2.0 Ports |
PCI Expansion Slots |
6 slots:
1 PCI-X full height, full length, 133MHz slot
1 PCI-X full height, half length, 133MHz slot
1 PCI-Express full height, full length x8 electrical/x16 physical slot
1 PCI-Express low profile x8 electrical/x8 physical slot
2 PCI-Express/XAUI low profile x4 electrical/x8 physical slots |
Internal Mass Storage |
Disks |
Up to 4 300GB SAS 2.5 inch form factor disk drives |
DVD-ROM |
1 slimline DVD-Writer/CD-Writer |
Power Supplies |
Two hot-swappable power supplies(AC/DC) providing N + 1 redundancy |
Environment |
Input Voltage |
DC: -48 VDC or -60 VDC nominal
AC: 100-240 V AC, 50-60 Hz |
Input Current - Total |
DC: 19 A maximum total for all inputs at -48 VDC
AC: 6 A maximum total for all inputs at 100-120 VAC |
Output Power |
660 Watts maximum, using one power supply |
Heat Output |
1365 BTU/hr (1440 KJ/hr) |
Temperature |
Operating: 5° C to 40° C (41° F to 104° F)
Short Term: -5° C to 55° C (23° F to 131° F)
|
Humidity |
Operating: 10% to 90% relative humidity noncondensing, short term,
-5°C to 55°C (80.6° F) wet bulb
Short Term: 5% to 90%, non-condensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lb. dry air)
Nonoperating: 93% relative humidity noncondensing, 37.7° C (100.4°
F) wet bulb |
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:Y |
NEBS |
Level 3 Compliant |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations,
IEC825-1,2 CFR21 part 1040, CNS14336, GB4943 |
Ergonomics |
EK1-ITB-2000 |
RFI/EMI |
EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548
Class A CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2,
GB17625.1, EN61000-3-3 |
Immunity |
EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC
61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
Telecommunications |
EN 300-386, IEC 60068 |
Dimensions and Weight |
Height |
87.4 mm (3.44 in.) |
Width |
442 mm (17.4 in.) |
Depth |
525 mm (20.67 in.) |
Weight |
17.5 kg (38.5 lb.) |
Clearance
and Service Access |
Front |
910 mm (36 in.) |
Rear |
910 mm (36 in.) |