Processor |
Number |
Two UltraSPARC T2 Plus, multi-core, multi-thread processors |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
1.2GHz 4-Core (64 × 2 for a total of 128 concurrent threads)
1.2GHz 6-Core (64 × 2 for a total of 128 concurrent threads)
1.2GHz 8-Core (64 × 2 for a total of 128 concurrent threads)
1.4GHz 8-Core (64 × 2 for a total of 128 concurrent threads) |
Cache memory |
4MB Level 2 |
Main Memory |
Capacities |
Total DIMM slots: 16 slots on the System board, 16 slots on the (optional) Memory Mezzanine
32 slots total (w/ Memory Mezzanine installed.)
DIMM type: FBDIMM
DIMM size: 2GB or 4GB
Maximum capacity: 128GB (32 × 4GB) maximum, 32GB (16 ×
2GB) minimum
|
Standard Integrated Interfaces
|
Network |
4 × 10/100/1000 Mbps auto-negotiating Ethernet ports
2 × 10 Gbps Ethernet ports via the two XAUI slots |
Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
Serial Management |
One dedicated 10/100Base-T RJ-45 port |
Serial |
One DB-9 serial port connector |
SAS
|
One LSI Logic SAS1068E 8-port, 3.0 Gbit/sec. SAS/SATA Controller |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports |
PCI Expansion Slots |
Six PCI Express slots MD2 low profile
(four x8 Mechanical/x8 Electrical, two x8 Mechanical/x4 Electrical)
Two PCI Express slots (Full Height, Full Length)
x16 Mechanical/x8 Electrical
Two PCI-X slots 64-bit/133MHz, 3.3V (Full Height, Full Legnth)
Note:If an XAUI card is installed in the XAUI4 or XAUI5 slots, PCI-E Slots 4 & 5 cannot be used, and
Ethernet Ports 0 & 1 on the motherboard will be disabled. |
Alarms |
Four fail-safe, dry contact alarms (critical, major, minor and user) |
Internal Mass Storage |
Disks |
Up to twelve 2.5" SAS Disk Drives (146 GB or 300GB, 10K RPM) with add-on SAS Host Bus Adapter (HBA). |
DVD-ROM |
One slimline slot-loaded DVD-R/W |
Power Supplies |
Four redundant, 658W AC or 660W DC power supplies
Maximum AC input = 7.56A @ 100 VAC (Full output load 658W assuming min efficiency at full load 87%)
Maximum DC input = 18.75A @ -40VDC (Full output load 660W assuming min efficiency at full load 88%
|
Environment |
AC power |
100-240 V AC (50-60 Hz) |
DC Power
|
-48 V DC or -60 V DC (nominal)
-40 V DC or -75 V DC (range)
|
Temperature |
Single, non-rack system:
Operating: 0° C to 40° C (41° F to 104° F)
Short Term: -5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
Humidity |
Single, non-rack system:
Operating: 5% to 85% relative humidity non-condensing
Short Term: 5% to 90%, non-condensing, but not to exceed 0.024 kg water/kg dry air (0.053 lbs. water/2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing,
40° C (104° F) max wet bulb |
Altitude |
Single, non-rack system:
Operating: up to 3000 m (9,850 ft.) @ 40° C
Nonoperating: up to 12,000 m (40,000 ft.) |
Acoustic noise |
Single, non-rack system:
LwAd (1B=10dB)
7.2 B (operating)
7.0 B (idle)
|
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:Y |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all national differences, IEC825-1,2, and
CFR21 part 1040 |
RFI/EMI |
FCC CFR 47 Part 15 Class A, EN55022/CISPR22 Class A |
Immunity |
EN55024/CISPR24, EN61000-3-2, EN61000-3-3 |
Telecommunications |
EN300-386 |
NEBS |
NEBS Level 3 Certified by Telcordia |
Seismic |
GR-63-CORE requirements for earthquake zone 4 |
Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, Gost-R, BSMI Class A
|
Dimensions and Weight |
Height |
174.2 mm (6.86 in.) |
Width (including bezel) |
445 mm (17.5 in.) |
Depth |
530 mm (20.87 in.) maximum to PSU handles
505 mm (19.88 in.) to the rear I/O |
Weight |
33 kg (72.6 lb.) fully configured w/o PCI cards
|
Rack Mounting |
Netra T5440 server racks (using either the X4059A, X4061A or X4076A rackmount kits) |
Racks are as follows:
- Sun Rack 938
- Sun Rack 1038
- Sun Rack 1042
|