Processor |
Number |
Two Quad-core |
Architecture |
Type: Quad-Core Intel Xeon L5408 (2x6MB L2, 2.13 GHz, 1066 MHz FSB, 40W)
|
Cache memory |
2x6MB Level 2 Cache
|
Main Memory |
Capacities |
DIMM slots per CPU socket: 8
Total DIMM slots (when 2 CPU's are installed): 16
DIMM type:PC2-5300 DDR2 667MHz Registered DIMMs (128-bit plus ECC databus)
DIMM size: 1GB, 2GB, 4GB
Maximum capacity: 64 GB (when configured with 4GB DIMMs)
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000Base-T Ethernet ports |
Network Management |
One 10/100Base-T Ethernet port |
Serial Management |
One TIA/EIA-232-F asynchronous RJ45 port |
SAS |
Four-Channel SAS Interface, internal access only |
USB (2.0)
|
Rear: 2
(500 mA=max output supply current of each USB port)
|
Video
|
One VGA Video port (HD-15)
|
Alarms
|
Four DB-15 dry contact (critical, major, minor and user)
|
Expansion Bus |
Two full-height internal 64-bit 133MHz PCI-X slots, 1 full-length, 1 half-length
Three internal x8 PCI-Express MD2 low profile slot
One internal x8 PCI-Express full-height, full-length slot
|
Internal Mass Storage |
Option 1
|
DVD-R/W, up to two 146GB 2.5in 10K
RPM SAS disks, maximum capacity 292 GB |
Option 2
|
No DVD-R/W, Up to four 146GB 2.5in 10K RPM
SAS disks, maximum capacity 584 GB
|
DVD-ROM |
One Slimline DVD/RW
|
NOTE: A two-disk
Netra X4250 chassis with DVD-ROM (or w/out DVD-ROM)
cannot be field converted to a four-disk Netra X4250, or vice versa. |
Power Supplies |
Two 650W (1+1)
hot-swappable AC or DC
Note: To ensure redundant
operation of the power supplies, the two power inputs should be
connected to separate power sources.
|
Operating input voltage range
|
AC=100-240 VAC, 50-60 Hz
DC=-48VDC or -60VDC (nominal) / -40VDC - -75VDC (range)
|
Max operating input current
|
AC=7.56 at 100-120 VAC / 3.2A at 200-240 VAC
DC=18.75 at -40VDC / 10.2A at -60VDC
|
Max heat dissipation
|
AC=2581 BTU/hr
DC=2581 BTU/hr
|
Nominal Power
|
AC & DC=Estimated 475 W
|
Maximum Power
|
550 W
|
Environment |
Temperature |
Operating: 5° C to 40° C (41° F to
104° F)/Short term: 5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
Storage: 40° C to
-70° C (-40° F to 158° F)
|
Humidity |
Operating: 5% to 85% relative humidity noncondensing,
max wet bulb. Short term: 5% to 90% relative humidity
noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs.
water 2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing,
38° C (100.4° F) max wet bulb
|
Altitude |
Operating: up to 3,000m (9,850 ft.) @40° C
(104° F)
Nonoperating: up to 12,000m (40,000 ft.) |
Acoustic noise |
Operating/Idling Acoustic Noise 7.0B (LwAd, 1B=10dB) |
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:YL |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all
country deviations, IEC825-1, 2, and CFR21 part 1040 |
RFI/EMC |
EN55022/CISPR22 Class A, FCC CFR47 Part 15 Class A
|
Immunity |
EN55024/CISPR24, EN61000-3-2, EN61000-3-3
|
Telecommunications
|
EN 300 386, Telecordia SR 3580 NEBS Level 3
|
Regulatory Markings (Pending)
|
CE, FCC, ICES-003, C-tick, VCCI,
GOST-R, BSMI, MIC, UL/cUL, CCC
|
ETSI
|
EN 300 019-2-1,2,3, Class 1.2, 2.3, 3.1E
- Except condensing humidity
- Except rain
|
Seismic
|
GR-63-CORE requirements for earthquake zone 4
|
Dimensions and Weight |
Height |
87.1 mm (3.43 in.) 2 RU
|
Width |
445 mm (17.52 in.) including bezel
|
Depth |
526 mm (20.71 in.) max depth / 501 mm (19.72 in.) to rear I/O
|
Weight |
Approximate (without PCI cards)
17.5 kg (38.5 lb.)
|
Rack Mounting |
Rack Units
|
2
|
Fits into standard
19-inch wide rack. Rack kit included: 19-inch 4-post |
|
Additional Rack Kits Available |
- 19-inch 2-post
- 23-inch 2-post
- 600mm x 600mm and
- 19-inch 4-post slide adjustable1
|
1 The slide kit includes hardware that
enables mounting to any of the following types of rack rails:
- 6 mm threaded holes
- #10-32 threaded holes
- #10 threaded holes
These must be compliant racks which have mounting
depths of 27-30 inches. |