Processor |
Number |
Two Intel Quad-core |
Architecture |
Type: Quad-Core Intel Xeon L5518 (8MB L3, 5.86 GT/s QPI, 2.13 GHz, 1066 MHz FSB, 60W)
|
Cache memory |
32KB instruction and 32KB data L1 cache per core
256KB unified (data and instruction) L2 cache per core
8MB shared inclusive L3 cache per processor
|
Main Memory |
Capacities |
DIMM slots per CPU socket: 9
Total DIMM slots (when 2 CPU's are installed): 18
DIMM type: PC3-10600 DDR3-1333 Registered DIMMs
PC3-8500 DDR3-1066 Registered DIMMs
DIMM size: 4GB, 8GB
Maximum capacity: 144 GB (when configured with 8GB DIMMs)
|
Standard
Integrated Interfaces |
Network |
Four 10/100/1000Base-T Ethernet ports |
Network Management |
One 10/100Base-T Ethernet port |
Serial Management |
One TIA/EIA-232-F asynchronous RJ45 port |
SAS |
Four-channel SAS Interface (with SFF-8088 connector), internal access only |
USB (2.0)
|
Rear: 2
|
Video
|
One VGA Video port (HD-15)
|
Alarms
|
Four fail-safe DB-15 dry contact (critical, major, minor and user)
|
Expansion Bus |
Two PCI-Express full-height, full length slots (x8 electrical, x16 mechanical)
Four x8 PCI-Express MD2 low profile slots
Note: PCI-Express MD2 slot 3 is reserved for the internal SAS host bus adapter
|
Internal Mass Storage |
Option 1
|
DVD-R/W, up to two 300GB 2.5in 10K
RPM SAS disks, maximum capacity 600GB |
Option 2
|
No DVD-R/W, Up to four 300GB 2.5in 10K RPM
SAS disks, maximum capacity 1.2TB
|
DVD-ROM |
One Slimline DVD/RW
|
Power Supplies |
Two 660W (1+1)
hot-swappable DC
Note: To ensure redundant
operation of the power supplies, the two power inputs should be
connected to separate power sources.
|
Nominal input voltages
|
-48VDC or -60VDC
|
Operating input voltage range
|
-48VDC or -75VDC
|
Max operating input current
|
15.4 A at -48VDC (740 VA)
|
Maximum Operating Input Power
|
740 W
|
Environment |
Temperature |
Operating: 5° C to 40° C (41° F to
104° F)/Short term: 5° C to 55° C (23° F to 131° F)
Nonoperating: -40° C to 70° C (-40° F to
158° F)
|
Humidity |
Operating: 5% to 85% relative humidity noncondensing,
max wet bulb. Short term: 5% to 90% relative humidity
noncondensing, but not to exceed 0.024kg water/kg dry air (0.053 lbs.
water 2.205 lb. dry air)
Nonoperating: up to 93% relative humidity noncondensing,
40° C (104.4° F) max wet bulb
|
Altitude |
Operating: up to 3,000m (9,850 ft.) @40° C
(104° F)
Nonoperating: up to 12,000m (40,000 ft.) |
Acoustic noise |
Operating/Idling Acoustic Noise 7.2B (LwAd, 1B=10dB) |
Regulations
Meets or exceeds the following
requirements: |
RoHS Compliance Level |
RoHS:Y |
Safety |
UL/CSA-60950-1 2nd edition 2007-03-27, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS`4336, GB4943 |
Ergonomics |
EK`-ITB-2000 |
RFI/EMC |
EN55022:2006+A1:2007/CISPR22:2005+A1+A2:2006 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A,GB17625.1, EN61000-3-3, EN61000-3-3
|
Immunity |
EN55024, IEC 61000-4-2 Electrostatic discharge, IEC 61000-4-3 RF E-field immunity, IEC 61000-4-4 Electrical Fast Transient/Burst, IEC 61000-4-5 Surge, IEC 61000-4-6 RF-Conducted immunity, IEC 61000-4-8 Power frequency magnetic field immunity, IEC 61000-4-11 Voltage dips, short interruptions
|
Telecommunications
|
EN 300 386, IEC 60068, Telcordia NEBS Level 3
|
Regulatory Markings
|
CE, FCC, ICES-003, C-tick, VCCI,
GOST-R, BSMI, KCC, UL/cUL, UL/DEMOKO/GS, UL/S-mark, CCC
|
Seismic
|
GR-63-CORE requirements for earthquake zone 4
|
Dimensions and Weight |
Height |
87.4 mm (3.44 in.) 2 RU
|
Width |
442 mm (17.4 in.) including bezel
425.5 mm (16.75 in.) chassis |
Depth |
To connector plane: 500 mm (20 in.)
Max overall: 525 mm (20.67 in.)
|
Weight |
Approximate (without PCI cards)
18.7 kg (41.23 lb.)
|
Service Access Clearance |
Front: 91 cm (36 in.)
Rear: 91 cm (36 in.)
|
Rack Mounting |
Rack Units
|
2
|
Fits into standard
19-inch wide rack. Rack kit included: 19-inch 4-post |
|
Racks Available |
- Sun Rack 900-38
- Sun Rack 900-36N
- Sun Rack 1000-38
- Sun Rack 1000-42
- Sun Rack II-1042
- Sun Rack II-1242
- Third Party ANSI/EIA-310-D-1992 or IEC 60927-compliant racks
in 19-inch/482.6mm panel-width series
|
Additional Rack Kits Available |
- 19-inch 2-post
- 23-inch 2-post
- 600mm x 600mm and
- 19-inch 4-post slide adjustable1
- 19-inch 4-post slide mount kit with cable management arm
|
1 The slide kit includes hardware that
enables mounting to any of the following types of rack rails:
- 6 mm threaded holes
- #10-32 threaded holes
- #10 threaded holes
These must be compliant racks which have mounting
depths of 27-30 inches. |