Processor |
Number |
One CPU |
Architecture |
SPARC64 VII: 2.52GHz or 2.75GHz Dual or Quad Core processor,
SPARC V9, ECC Protected
SPARC64 VII+: 2.86GHz Dual or Quad Core processor, SPARC V9, ECC
Protected |
Cache memory |
SPARC64 VII: 5MB Shared Level 2 on Chip Cache, 64KB
I-Cache and 64KB D-Cache Level
SPARC64 VII+: 5.5MB Shared Level 2 on Chip Cache, 64KB I-Cache and
64KB D-Cache Level |
Main
Memory |
Capacities |
8GB (using 1GB DDR2 DIMMS) to 64GB (using 8GB DDR2
DIMMs), 8 slots per system. DIMM sizes: 1GB, 2GB, 4GB and 8GB.
|
Standard
Interfaces |
Ethernet |
4 × integrated Gigabit Ethernet ports also
2 × 10/100 ethernet ports for accessing CLI and browser based interface
on Extended System Control Facility (XSCF) |
PCI-X / PCI-Express |
4 × X8 PCI-E Slots |
Serial |
One RJ45 |
USB |
One port on XSCF that field engineer can use to
download hardware information |
SAS |
One external SAS port (two-lane) |
Internal
Mass Storage |
Disks |
Up to 4 internal 146GB SAS Disk Drives |
DVD-ROM |
1 DVD-RW |
Tape |
None |
Power
Supplies |
Type |
1 or 2 × 100-240 VAC, 565W,
1-phase (50-60Hz), 12 amp per power cord |
Output |
600 Watts (2 power cords) |
Environment |
AC Power |
100-240VAC |
DC Power |
~48V/~60V |
Input power |
100 127 VAC
200 240 VAC |
Power Draw |
470 Watts (2 power cords) |
Maximum Current |
24.0A at 100 127 VAC, 12A / cord
12.0A at 200 240 VAC, 12A / cord |
Heat output |
2150 BTU/hr |
Temperature |
Operating: 5° C to 35° C (41°
F to 95° F) *
Nonoperating: -20° C to 60° C (-4°
F to 140° F) *
Optimal: 21°
C to 23° C (70° F to 74° F) |
Humidity |
Operating: 20% to 80% relative humidity,
noncondensing
Nonoperating: 8% to 80% relative humidity,
noncondensing
Optimal: 45%
to 50% relative humidity, noncondensing |
Altitude |
Operating: Up to 3048m (10000 ft)
Nonoperating: 12000m (40000 ft) |
* - derated 2° C for every 1km
up to 3km |
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:YL, WEEE and Chinese RoHS |
Safety |
CSA60950-1-03, UL60950-1, IEC60950-1, 1(2001), GB4943-2001
Scheme with all national deviations |
Ergonomics |
N/A |
RFI/EMI |
FCC part-15, EN55022/CISPR22, VCCI, AS/NZS CISPR 22, EN 300
386, EN61000-3-2, EN61000-3-3, JISC61000-3-2, KN22, GB9254, GB17625 |
Immunity |
EN55024, EN 300 386, KN24 |
Regulatory Markings |
CE, FCC, VCCI, CSA C/US |
Dimensions
and Weights |
Height |
8.7 cm (3.43 in) |
Width |
44 cm (17.33 in) |
Depth |
65.7 cm (25.87 in) |
Weight |
22kg (48.50 lbs) |
Power Cord |
1 - 2, 4m (13 ft) *
Americas, Japan, & Taiwan: NEMA L5-15 125V 15A, NEMA L6-20 250V 20A
All other locations except Japan & Taiwan: IEC 60309 16A 250V, 3PIN
with IEC60309 C20 |
* - 2 power cords required for redundancy |
Clearance
and Service Access |
Front |
91.4cm (36 in) |
Rear |
91.4cm (36 in) |
Right |
none - front to back cooling |
Left |
none - front to back cooling |
Top |
91.4cm (36 in) |
Airflow |
Front to back - 8.5 cubic meters per minute (300 cfm) in normal
operating conditions |
Rack
Mounting |
Sun Rack 1000-38, Sun Rack 1000-42,
Sun Rack 900 |