Processor |
Number |
One UltraSPARC T2 multicore processor |
Architecture |
SPARC V9 architecture, ECC protected |
CPUs |
1.2GHz 4-Core
1.2GHz 6-Core
1.2GHz 8-Core
1.4GHz 8-Core
1.6GHz 8-Core
|
Cache memory |
4MB Level 2 |
Main Memory |
Capacities |
Total DIMM slots: 16
DIMM type: FBDIMM
DIMM size: 1GB, 2GB, 4GB or 8GB
Maximum capacity: 128GB (16 × 8GB)
|
Standard Integrated Interfaces
|
Network |
4 × 10/100/1000 Mbps ports |
Network Management |
One dedicated 10/100Base-T RJ-45 port Ethernet port |
Serial Management |
One dedicated RJ-45 port |
Serial |
One DB-9 connector |
SAS
|
One LSI Logic SAS1068E SAS/SATA Controller chip interfacing to a four
lane PCI-Express port |
USB |
Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports |
PCI Expansion Slots |
- 3 low-profile PCI-Express slots.
- Slots 0 and 1 support PCI-Express or proprietary 10Gbit Ethernet (XAUI) cards.
Slot #
|
Physical
|
Electrical
|
0
|
x8
|
x4
|
1
|
x8
|
x4
|
2
|
x16
|
x8
|
|
Internal Mass Storage |
Disks |
- All PTO standard configurations ship with 4 disk backplanes and cannot be changed later.
- ATO configurations provide a 4 disk or 8 disk backplane option as a selectable item.
- The maximum disk capacity depends on which backplane is selected, and cannot be changed later.
- Up to 8 73GB (10K or 15K RPM), 146GB 10K RPM, and 300GB, 10K RPM SAS 2.5 inch form factor disk drives
|
Solid State Drives |
- Up to 4 32GB solid state drives
|
DVD-ROM |
1 slimline DVD-Writer/CD-Writer |
Power Supplies |
2 × 658 Watt, hot-swappable, N+1 redundant power
supply units (PSU) |
Environment |
Input Voltage |
100 - 240 VAC, 50-60Hz |
Input Current |
<8.2A RMS @ 100 VAC
2.5A @ 200-240 VAC (max) |
Idle/Peak Power |
Minimum Configuration: 216 / 285 W
Maximum Configuration: 384 / 641 W |
Power Consumption |
641 W max |
Heat Output |
100V at 20% load is 82% efficient 1.22x658W=802.76W and 2739BTU/hr
100V at 50% load is 87% efficient 1.15x658W=756.70W and 2581BTU/hr
100V at 100% load is 87% efficient 1.15x658W=756.70W and 2581BTU/hr
100V at 20% load is 83% efficient 1.20x720W=867.47W and 2959BTU/hr
100V at 50% load is 87% efficient 1.15x720W=828.00W and 2825BTU/hr
100V at 100% load is 87% efficient 1.15x720W=828.00W and 2825BTU/hr |
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Note: Above 900m (3000 ft), decrease maximum temperature as altitude
increase, 1° C/300m (1.6° F/1000ft)
|
Humidity |
Operating: 10% to 90% relative humidity noncondensing, 27°
C (80.6° F) wet bulb
Nonoperating: 93% relative humidity noncondensing, 35° C (95°
F) wet bulb |
Altitude |
Operating: up to 3000m (10000 ft.)
Nonoperating: up to 12000m (40000 ft.) |
Vibration |
Operating: 0.15G (z-axis), 0.10G (x,y axes) 5-500Hz sine
Nonoperating: 0.5G (z-axis), 0.25G (x,y axes) S5-500Hz sine |
Shock |
Operating: 3G, 11ms half-sine
Nonoperating: 1-inch roll-off front-to-back, 20mm step up threshold
testing of castors at 0.75m/s |
Regulations
Meets or exceeds the following requirements: |
RoHS Compliance Level |
RoHS:Y |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations,
IEC825-1,2 CFR21 part 1040, CNS14336, GB4943 |
Ergonomics |
EK1-ITB-2000 |
RFI/EMI |
EN55022 Class A, 47 CFR 15B Class A, ICES-003 Class A, VCCI Class A, AS/NZ3548
Class A CNS 13438 Class A, KSC 5858 Class A, GB9254 Class A, EN61000-3-2,
GB17625.1, EN61000-3-3 |
Immunity |
EN55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC
61000-4-6, IEC 61000-4-8, IEC 61000-4-11 |
Telecommunications |
EN 300 386 |
Dimensions and Weight |
Height |
44.4 mm (1.75 in.) |
Width |
425.5 mm (16.75 in.) |
Depth |
714.4 mm (28.1 in.) |
Weight |
16.55 kg (36.5 lb.) |
Clearance
and Service Access |
Front |
910 mm (36 in.) |
Rear |
910 mm (36 in.) |
Rack Mounting |
Racks are as follows:
- Sun Rack 900-36N
- Sun Rack 900-38
- Sun Rack 1000-38
- Sun Rack 1000-42
- Sun Fire Cabinet
- StorEdge 72" Expansion Cabinet
- 19" racks that meet EIA-310-D, including M6, 10-32, and square
holes
|