Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

SPARC[tm] T3-1 Server: Hardware Specifications

Processor
Number One SPARC T3 16-Core 1.65GHz processor
Architecture SPARC V9 architecture
CPUs
  • 1.65GHz 16-Core
  • 128 threads max
  • Sixteen floating-point units
  • Dual multithreaded 10 GbE PCI integrated onto chip
  • On-board cryptography with new Kasumi Bulk algorithm, supporting 12 embedded security industry-standard ciphers:
    DES, 3DES, AES, RC4, SHA1, SHA256, SHA384, SHA512, MD5, RSA to 2048 key, EX, CRC32
Cache memory 6MB integrated L2
Main Memory
Capacities
  • Total DIMM slots: 16 on system board
  • DIMM type: DDR3
  • DIMM size: 2GB, 4GB or 8GB
  • Minimum Configuation: 8GB (4 × 2GB)
  • Maximum capacity: 128GB (16 × 8GB)
Standard Integrated Interfaces
Network 4 × 10/100/1000 Mbps autonegotiating ports
Up to 2 .× optional 10 GbE XAUI connections
Network Management One dedicated 10/100Base-T RJ-45 port Ethernet port
Serial Management One dedicated RJ-45 port
Remote Management Onboard system processor, running Integrated Lights Out Manager (ILOM) 3.0
Graphics One DB-15 VGA connector
USB Front: 2 USB 2.0 Ports
Rear: 2 USB 2.0 Ports
(also 1 internal USB port)
PCI Expansion Slots
  • 6 low-profile PCI-Express 2.0 slots.
  • Slots 0 and 3 support PCI-Express or 10Gbit Ethernet (XAUI) cards.
Slot # Physical Electrical
0 x16 x8
1 x16 x8
2 x16 x8
3 x8 x8
4 x8 x8
5 x8 x8
Internal Mass Storage
Disks
  • Up to eight or sixteen 2.5-inch SAS drives, depending on selected disk backplane
  • 300GB 2.5-inch SAS disk drives
  • RAID 0 and RAID 1 support
DVD-ROM 1 slimline SATA DVD +/-RW including two USB ports
Power Supplies
2 × 1200 Watt, hot-swappable, N+1 redundant power supply units (PSU)
Environment
Input Voltage 100 - 240 VAC, 50-60Hz
200 - 240 VAC, 50-60Hz
Input Current 8 Disk:
8.4 A @ 100 VAC max
4.2 A @ 200 VAC max

16 Disk:

9.4 A @ 100 VAC max
4.7 A @ 200 VAC max
Input Power 8 Disk:
800 W @ 100 VAC max
792 W @ 200 VAC max

16 Disk:
896 W @ 100 VAC max
888 W @ 200 VAC max
Heat Output 8 Disk:
2730 BTU/hr @ 100 VAC max
2702 BTU/hr @ 200 VAC max

16 Disk:
3057 BTU/hr @ 100 VAC max
3030 BTY/hr @ 200 VAC max
Temperature

Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)

Note: Above 900m (3000 ft), decrease maximum temperature as altitude increase, 1° C/300m (1.6° F/1000ft)

Humidity Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) maximum wet bulb
Nonoperating: 93% relative humidity noncondensing, 35° C (95° F) maximum wet bulb
Altitude Operating: up to 3000m (10000 ft.)
Nonoperating: up to 12000m (40000 ft.)
Vibration Operating: 0.15G (x-axis), 0.10G (x,y axes) 5-500Hz swept sine
Nonoperating: 0.5G (x-axis), 0.25G (x,y axes) 5-500Hz swept sine
Shock Operating: 3Gs, 11ms half-sine
Nonoperating: 1-inch roll-off free fall, front-to-back rolling direction, 25mm threshold height at 0.75 m/s impact velocity
Acoustic Noise Operating/Idling: 7.1 B (LwAd, 1B = 10dB)
Operating/Idling: 63dB (LpAm, bystander positions)
Regulations
Meets or exceeds the following requirements:
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part 1040, CNS14336, GB4943
RFI/EMI EN55022 Class A 47 CFR 15B Class A ICES-003 Class A VCCI Class A AS/NZ 3548 Class A CNS 13438 Class A KSC 5858 Class A GB9254 Class A EN61000-3-2 GB17625.1 EN61000-3-3
Immunity EN55024 IEC 61000-4-2 IEC 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8 IEC 61000-4-11
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/DEMKOLVD, UL/S-mark, CCC
European Union Directives 2006/95/EC (73/23/EEC) Low Voltage Directive, 2004/108/EC (89/336/EEC) EMC Directive, 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) Directive, 2002/95/EC Restriction of Hazardous Substances (RoHS) Directive
Dimensions and Weight
Height 88.65 mm (3.49 in.)
Width 447 mm (17.6 in.)
Depth 673.1 mm (26.5 in.)
Weight Appx 27.2 kg (60 lbs) - with 2 power supplies and 16 disk drives, but without PCI cards and rackmount hardware
Clearance and Service Access
Front 910 mm (36 in.)
Rear 910 mm (36 in.)

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback