Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

ISP-80 / IPI-2

Sun-4/390/470/490
SS670MP / SS690MP

Options 408 / 418
501-1539 / 501-1855



Power:

11.8 Amps @ +5Vdc
59.0 Watts

Base Address Select Switches

DIP SWITCH 1 2 3 4 5 6 7 8
SW1603 AM0 AM1 A10 A11 A12 A13 A14 A15
SW1602 A16 A17 A18 A19 A20 A21 A22 A23
SW1601 A24 A25 A26 A27 A28 A29 A30 A31

Switch and Jumper Settings



Note

Dip Switches 3, 4, and 5 of SW1603, select bits A10, A11, and A12 of the controller base address. These are the only switches changed to configure multiple controllers.

Jumper JM2

PINS SETTING DESCRIPTION
1-2 In Enable UART clock

ISP-80 / IPI-2

A minimum ISP-80 firmware level is required to support these products.
PRODUCT U0501 U0502 U0503
911MB Disk 525-1023-05 525-1024-07 525-1025-07
Prestoserve 525-1023-05 525-1024-08 525-1025-08
1.3GB Disk 525-1023-05 525-1024-08 525-1025-08
Dual Port 525-1023-05 525-1024-09 525-1025-09
SNC 1.2 525-1023-05 525-1024-10 525-1025-10

These ISP-80 part numbers have the firmware level required for the products listed.
PRODUCT ISP-80 ISP-80
4400 CPU 501-1539-04 501-1855-01
911MB Disk 501-1539-05 501-1855-01
Prestoserve 501-1539-08 501-1855-02
1.3GB Disk 501-1539-09 501-1855-03
Dual Port 501-1539-09 501-1855-03
SNC 1.2 501-1539-10 501-1855-04
DP Bug fixes 501-1539-10 501-1855-04

Notes

  1. Upgrade lower revision ISP-80 boards with firmware Option X2080A.
  2. Do not install firmware Option X2080A on ISP-80 501-1539-06. An unused trace may cause a system reset. Replace the ISP-80.
  3. Booting from an alternate controller (1, 2, 3, or 4) is not supported on the 4300 and 4400 systems. Refer to Bug ID 1027710.

References

  1. ISP-80 Disk Controller Configuration Procedures, 813-2065-10.
  2. ISP-80 Disk Controller Installation and Configuration Procedures for the Sun 12-Slot Office Pedestal, 813-1103-10.
  3. ISP-80 Disk Controller Installation and Configuration Procedures, 813-1050-11.
  4. ISP-80 Disk Controller PROM Upgrade Manual, 813-6089-11.


Last updated: December 2, 1996
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback