Capacity
Number
  • Up to 20 optional PCI ExpressModules.
  • Up to 4 optional PCI Express Network Express Modules (NEM).
  • Up to 10 hot-pluggable Sun Blade Server Modules.
  • 6, 3000-Watt, grid redundant power supplies; up to 735W budgeted per blade; 9000W total system power.
  • 3 fan modules to cool the PCI Express ExpressModules.
  • Up to 2 redundant Chassis Monitoring Modules with failover capability.
  • 9 high-performance fans to cool the blades.
  • 160 Gbps of I/O throughput via PCIe lanes to the midplane
Management Environment
The Sun Blade 8000 Modular System has a tiered system management architecture that allows management at either the chassis level or the Server Module level.
Common System Management for both the Chassis and the Server Module
  • Integrated Lights Out Management (ILOM) 1.1 with RKVMS (Remote Keyboard Video Mouse) is pre-installed on the CMM and the SP. ILOM will run on standby power. Note: Accessing ILOM through Mozilla will require Mozilla version 1.7.5 or greater.
  • Support for Sun N1 System Manager 1.3.1.
  • Compatibility for third-party SNMP system managers with requirements for SNMP (v1, v2C, v3) and IPMI (2.0).
  • System management is consistent with Sun Fire X4100 and Sun Fire X4200 servers.
Sun Blade 8000 Chassis Monitoring Module (CMM)
  • For redundancy, a second CMM is optional.
  • 1 RJ-45 dedicated management network 100BaseT port for Secure Shell CLI to ILOM, web GUI access to ILOM, IPMI 2.0, and SNMP v1, v2C, and V3.
  • A DB-9 serial port to access ILOM CLI.
  • 1 RJ-45 AUX port is currently not functional.
  • The CMM's network ports are independent and do not interfere with network data traffic on, for example, a Network Express Module (NEM) communication option.
  • Connections to CMM's Serial Management (DB-9 SERIAL MGT) port:
    • Laptop USB to SERIAL MGT port via serial null modem or cross over cable.
    • Network to Dongle DB9F to RJ45F, DCE Adapter (part number 530-3813 ships with chassis) to SERIAL MGT port.
  • Managing through the CMM does allow Server Module level management.
Power Supplies
Number Six, hot-plug / hot-swap, high-efficiency(~87%) power supplies are provided in a 3+3 redundant configuration.
Output 3000 W per power supply
Standard Integrated Interfaces
Network The Sun Blade 8000, without an optional EM or NEM, does not offer network or I/O connectivity.
Network Management The CMM provides one RJ-45 100BaseT port and a DB-9 Serial Management port, the Server Module provides a DB-9 serial port. Reference the Management Environment section.
PCI Interfaces The Sun Blade 8000 Modular System I/O is architected using PCI Express technology with total I/O output of 1,920 Gbps when fully populated with 10 Server Modules. The Sun Blade 8000 chassis can support:
  • Up to two optional I/O PCI Express ExpressModules (EMs)
    and
  • Up to four Network Express Modules (NEMs)
  • USB Each optional Server Module provides two USB 2.0 ports.
    Video Each optional Server Module provides a VGA Video connection to the ATI Rage XL graphics chip.
    Environment
    AC input
    • Voltage: 200-240 VAC
    • Frequency: 50-60 Hz
    • Current: 16A per AC input
    • Number of AC Inputs: 6
    • Maximum in-rush current: 40A
    • Power Factor: 0.98
    Input power
      AC input connection:
    • AMER- L6-20P to IEC 320 C19; 2.5m; Sun PN 180-2005-01
    • EPAC- IEC 309 to IEC 320 320 C19; 2.5m; Sun PN 180-2004-01
    • Preinstalled in rack with power distribution unit - IEC 320 C20 to IEC 320 C19
    Heat output
      Thermal Design:
    • Total system volumetric airflow (front to rear): 1500 (Cubic Feet per Minute)
    • Airflow direction: Front to back
    • Total heat dissipation / HVAC load: 30,735 BTU/hr (assuming 9,000W)
    • Average temperature rise through chassis: 15° C (59° F)
    Temperature Operating: 5°C to 35°C (41° F to 95° F)
    Nonoperating: -40°C to 65°C (-40° F to 149° F)
    Relative Humidity Operating: 10% to 90% RH, non-condensing, 27° C max wet bulb
    Nonoperating: 5% to 93% RH, non-condensing, 38° C max wet bulb
    Altitude 0 to 7,500 feet (2,286m)
    Regulations
    Meets or exceeds the following requirements:
    RoHS Compliance Level RoHS:YL
    Product Safety
    • UL approved to UL 60950 and C22.2 No. 60950
    • TUV approved to EN60950-1 and CB Report IEC 950 3rd Edition; including all amendments and full worldwide deviations
    • GOST Certification
    • Korean MIC Certification
    • China CCC Mark for power supply only (system is exempt since it is rated greater than 1300W)
    • CE Declaration of Conformance to the Electronic Compatibility Directive and Low Voltage Directive with accompanying "Technical Data File"
    • Approval to Argentinian standards
    Laser Product and Optical I/O
    • FCC Regulation to Code of Federal regulations 21 CFR 1040-Lasers
    • TUV approval to IEC 60825-1 Safety of Laser Products
    • Canadian Radiation Emitting Devices Act REDR C1370
    Emissions and Immunities:
    Electromagnetic Interference
    • 47 CFR 15B (Code of Federal Regulations, Part 15, Subpart B) Class A
    • EN55022:1998 Class A per EMC directive 89/336/EEC (CE Mark)
    • VCCI Class A
    • Industry Canada ICES-003
    • AS/NZ 3548 (Australia/New Zealand)
    • CNS 13438 (Taiwan)
    Immunity
    • EN55024:1998 per EMC Directive 89/336/EEC
    • IEC 61000-4-2 Electrostatic discharge immunity test
    • IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test
    • IEC 61000-4-4 Electrical fast transient/burst immunity test
    • IEC 61000-4-5 Surge immunity test
    • IEC 61000-4-6 Immunity to conducted disturbances, induced by radio-frequency fields
    • IEC 61000-4-8 Power frequency magnetic field immunity test
    • IEC 61000-4-11 Voltage dips, short interruptions, and voltage variations immunity tests
    Line Distortion EN 61000-3-2 per EMC Directive 89/336/EEC
    Voltage Fluctuations and Flicker EN 61000-3-3 per EMC Directive 89/336/EEC
    Dimensions and Weights
    Chassis Height 838.49mm (33.01 in) - 19 RU minus clearance
    Chassis Width 444.5mm (17.50 in)
    Chassis Depth Includes chassis metal and front bezel:722mm (28.43 in)
    In rack, distance from front vertical mounting rail to rear of chassis:
    700mm (27.56 in)
    Weight Fully configured system 243.13kg (536lbs)
    Empty Chassis:
    11.34kg (94lbs)
    Rack Mounting
    Chassis=19U / 2 chassis max per 42U rack.