Note: Modular System (chassis) specifications are documented on the chassis specification page.
Reference the Servers/Blade section of the Handbook's Systems List to find documentation on Modular Systems.
|
Processor |
Number |
Up to four.
|
Architecture |
Type:Intel Xeon processors.
- Model/Speed: E7220, 2-Core, 2.93 GHz, 80W
- Model/Speed: L7345, 4-Core, 1.86 GHz, 50W
- Model/Speed: L7445, 4-Core, 2.13 GHz, 50W
- Model/Speed: E7320, 4-Core, 2.13 GHz, 80W
- Model/Speed: E7340, 4-Core, 2.40 GHz, 80W
- Model/Speed: E7440, 4-Core, 2.40 GHz, 90W
- Model/Speed: L7455, 6-Core, 2.13 GHz, 65W
- Model/Speed: E7450, 6-Core, 2.40 GHz, 90W
|
Cache Memory |
L2 Cache |
Main Memory |
Memory Type |
PC2-5300 DDR2 Fully Buffered DIMMs (FBDIMMs).
|
Capacities |
- Maximum memory: 192GB.
- Total DIMM slots: 24.
- DIMM sizes: 1GB, 2GB, 4GB and 8GB.
- Install DIMMs in pairs of two beginning with A0/B0.
|
IDE Compact Flash |
8GB Compact Flash Type II (supports Linux boot) is on the motherboard. |
Optional Storage |
Solid State Drives |
- 1 32GB solid state drive.
|
Management Environment
|
Sun Blade Server Module Service Processor (SP) |
- The SP is not a separate card. It is embedded on the motherboard.
- The SP is installed with Lights-Out Manager (LOM),
IPMI 2.0-compatible software.
- Embedded Lights-Out Manager (ELOM) and Integrated Lights-Out Manager (ILOM)
are supported.
- The factory pre-configured LOM transitioned to ILOM in September 2008.
- The SP card provides one 10/100 Management Ethernet Port to Midplane and the Chassis Monitoring Module (CMM).
The DB9-to-RJ45 serial adapter cable provides DB9 serial access to
the server module through an RJ45 connection.
- LOM on the SP card can be accessed via the Dongle cable's DB9 connector to the Universal Connector Port (UCP) RJ45 connector on the front of the Sun Blade X6450.
- The Dongle cable assembly is provided with the Sun Blade 6000 chassis and also orderable. Option X4621A.
- The SP card and LOM provide the following:
- A Browser User Interface (HTTP/HTTPS).
- DMTF/CLP based CLI and SSH.
- Support for RADIUS, LDAP, and MS Active Directory.
- IPMI 2.0 (Host access through KCS and remote).
- Compatibility for third-party SNMP system managers with requirements for SNMP (v1, v2C, v3).
- Remote KVMS/Java Console (redirected Keyboard Video Mouse and Storage through a JAVA Application).
- Support for Sun N1 System Manager.
|
Standard Integrated Interfaces |
Universal Connector Port (UCP)
|
The Dongle Cable Assembly (Option X4621A) that ships with the Sun Blade 6000 chassis connects to the UCP and provides the following:
- VGA HD15 port to AST2000 video controller with 128MB of shared SDRAM.
- 2 USB 2.0 ports.
- DB9 serial port (for connection to SP LOM).
- RJ45 port.
- DB9F to RJ45F DCE Adapter.
|
Network Management |
Two 10/100Base-T Ethernet connection via midplane to the CMM.
Only one connection (NET 0) is used.
|
Ethernet |
Two 10/100/1000Base-T Ethernet ports routed through midplane to 2 NEM slots.
|
PCI Interfaces with the Sun Blade Modular System (chassis) |
- I/O is offered in two form factors:
- PCI Express ExpressModules (EM)
and
- PCI Express Network Express Modules (NEM).
- Each Sun Blade X6450 has four, PCI Express links allocated to:
- Two EMs (X8)
and
- Two NEMs (X4).
- Each NEM has one link assigned to each server module. All server modules
share the NEM. For example, Blade 0 has access to NEM 0/slot 0,
and NEM 1/slot 0. Blade 1 to NEM 0/slot 1 and NEM 1/slot 1, etc.
- EM slots are not shared between server modules. Each EM slot is
specific to one server module.
|
Regulations
|
RoHS Compliance Level |
RoHS:YL |