|
Racking |
|
Fits into a standard 19 inch wide rack. Four post rack kit adjustable
between 720 mm and 925 mm
|
|
Processor |
| Number |
One or two |
| Architecture |
1.33GHz UltraSPARC® IIIi, 64 bit, 4-way Superscalar SPARC® V9 |
| Cache memory |
64 KB data, 32 KB instruction and 1 MB integrated L2 |
|
Main Memory |
| Capacities |
4 DIMM slots per processor, registered DDR-1 SDRAM
(PC2100/PC2700) 128 bit + ECC databus
System configurations from 512 MB to 16 GB
|
|
Standard Interfaces |
| Ethernet |
Four 10/100/1000 BaseT Ethernet
One 10 BaseT Ethernet (Network Management)
|
| PCI |
One 64 bit 33/66 MHz 3.3V full-length slot (PCI 2.2 compliant)
Note:Nominal power = maximum 25W |
| SCSI |
One Ultra-320 SCSI multimode (SE/LVD) |
| Serial |
One TIA/EIA-232-F asynchronous (DB9) Port
One TIA/EIA-232-F (RJ45) Port (Serial Management)
|
| System Configuration Reader and Card |
Front accessible for transfer of system configuration information,
including host ID
|
| USB |
Two OHCI-1.0 Compliant Interfaces, supporting dual speeds of 12 and 1.5
Mbits/sec each |
|
Internal Mass Storage |
| Disks |
Up to two hot-swap Ultra-320 SCSI 73GB, or 146GB Disks |
| DVD-ROM |
One Slim-line ATAPI DVD-ROM (Optional) |
|
Environment |
| AC input |
90 - 264 VAC (47 - 63 Hz) |
| Input power |
459 W |
Nominal power (calculated at 240V/50Hz) |
Minimum configuration: 206 Watts
(1 × 1.34GHz processor, 2 × 256MB DIMMs,
1 × 73GB HDD)
Maximum configuration: 411 Watts
(2 × 1.34GHz processors, 8 × 1GB DIMMs,
2 × 73GB HDDs, Crypto 500,
1 × DVD-ROM, 1 × PCI card [max power spec 25W])
Typical Minimum configuration: 179 Watts
(1 × 1.34GHz processor, 2 × 256MB DIMMs,
1 × 73GB HDD)
Typical Maximum configuration: 296 Watts
(2 × 1.34GHz processors, 8 × 1GB DIMMs,
2 × 73GB HDDs, Crypto 500,
1 × DVD-ROM, 1 × PCI card [max power spec 25W])
|
| Heat dissipation |
Minimum configuration: 704 BTU/hr
Maximum configuration: 1406 BTU/hr |
| Temperature |
Operating:
5° C to 40° C (41° F to 104° F)
Nonoperating:
-40° C to 65° C (-40° F to 149° F) |
| Humidity |
Operating:
10% to 90% relative humidity noncondensing, 27°C max wet bulb
Nonoperating:
Up to 93% relative humidity, noncondensing, 38°C max wet bulb |
| Altitude |
Operating: Up to 3000 m, maximum ambient temperature is derated
by 2° C per 500 m above 500 m
Nonoperating:
Up to 12000 m |
| Acoustic noise |
Operating:
Less than 7.3 B sound power in ambient temperature of up to 24° C
|
Regulations
Meets or exceeds the following requirements:
|
| RoHS Compliance Level |
RoHS:YL |
| Safety |
IEC60950, UL/CSA60950, EN60950 |
| Emissions |
FCC Class A, Part 15 47 CFR, EN55022, CISPR 22 |
| Immunity |
EN55024 |
| Certification |
Safety:
cULus Mark, TUV GS Mark, CE Mark
EMC:
CE Mark (93/68/EEC), FCC authorized Class A, VCCI, BSMI, CTICK
|
|
Dimensions and Weights |
| Height |
43.2 mm (1.7 in.) (1 RU) |
| Width |
425 mm (16.73 in.) |
| Depth |
635 mm (25 in.) |
| Weight |
12 kg (26.4 lb.) fully configured; 15.6 kg (34.31 lb.) with rack-mount
rails and cable management arm |