Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] V445 Server: Hardware Specifications

Processor
Number two to four
Architecture 1.593 GHz UltraSPARC IIIi
Cache memory 1 MB Level 2
Main Memory
Capacities 4 DIMM slots per processor.
Support for 512MB, 1 GB and 2 GB DIMMS.
DDR1 PC2700 DIMMs.
Minimum configuration:    4GB (two CPU/memory modules with four 512-MB DIMMs).
Maximum configuration: 32GB (four CPU/memory modules fully populated with 2-GB DIMMs).
Standard Interfaces
Ethernet 4 RJ-45 on board 10/100/1000BASE-T Gigabit/Fast Ethernet ports
PCI
  • 8 PCI slots (4 PCI-E slots/4 PCI-X slots)
  • NOTE: One of the short PCI-X slots may be occupied by a disk drive controller.
    New standard configurations with an integrated controller installed into the disk backplane are available, thereby making the previously occupied short PCI-X slot available. All systems that initially shipped with the PCI-X based disk controller can be upgraded in the field by ordering the FRU part F501-7244 - PCIe SAS-SATA Controller Board. The use of this controller will require the redefinition of the boot path as it is PCIe based, not PCI-X. It is encouraged that Services be contacted for the installation.
    System Management One Serial Management RJ45 port.
    One Network Management 10Base-T Ethernet, RJ45 port.
    Support for: Sun Management Center, Sun SNMP Management Agent, Advanced Lights Out Management (ALOM), Sun Net Connect, and Sun Update Connection.
    Serial 2 Serial Ports
  • 1 DB-9 connector and 1 RJ45 connector
  • The RJ45 port is used for serial management.
  • USB Four USB 2.0 compliant ports, two front and two rear.
    SCSI None
    Internal Mass Storage
    Disks
  • Up to 8 73GB or 146GB, 10,000rpm, 2.5" SAS disk drives.
  • Hardware RAID 0 and 1.
  • Drives are front-accessible, hot-pluggable.
  • DVD-ROM One internal combination CD/DVD-RW writer.
    Environment
    AC Power Consumption
    Typical Operating Range
    327 - 557 W for operation @ 100 VAC to 240 VAC.
    Maximum AC Input per Power Supply 660 W.
    Maximum DC Output per Power Supply 550 W.
    AC Power Consumption Typical Operating Range: 327 - 557 W for operation @ 100 VAC to 240 VAC.
    Heat Dissipation Typical Operating Range: 1065-2689 BTU/hr. for operation @ 100 VAC to 240 VAC
    Maximum Heat: 3157 BTU/hr. for operation @ 100 VAC to 240 VAC.
    Temperature Operating: 5°C to 35°C (41°F to 95°) non-condensing.
    Nonoperating: -40°C to 35°C (-40°F to 95°) non-condensing.
    Minimum temperature of -20°C is required if NiMH batteries are used.
    Humidity
    (IEC 60068-2-3&56 )
    Operating: 20% to 80% relative humidity, noncondensing, 27°C max wet bulb
    Nonoperating: Up to 93% relative humidity, noncondensing, 38°C max wet bulb
    Altitude
    (IEC 60068-2-13)
    Operating:0 to 3,000m (0 to 10,000 ft.); Max. ambient temperature is derated by 1° C per 500 m. above 500 m.
    Nonoperating: 0-12,000 m (0 to 40,000 ft.)
    Acoustics
    ISO 9295/9296
    (ISO 7779:1988)
    Operating: At full speed 75 dBA
    Nonoperating: N/A
    Declared acoustics is as declared in Bels, per ISO 9295/9296 because acoustics is the only test where there are no formal input-response scenarios that lead to pass-fail criteria.
    Vibration
    (IEC-60068-2-6&64)
    Operating: 0.0001 g2/Hz, 5 to 150 Hz, -12db /octave slope 150 to 500 Hz.
    Nonoperating: 0.001 g2/Hz, 5 to 150 Hz, -12db /octave slope 150 to 500 Hz.
    Shock Operating: 3.0 g peak, 11 milliseconds half-sine pulse —IEC 60068-2-27.
    Nonoperating: 15.0 g peak, 11 milliseconds half-sine pulse; 1.0 roll-off front to back, 0.5 inch roll-off side to side.
    Handling Drops
    (IEC 60068-2-31)
    60 mm, 1 drop per corner, 4 corners.
    Threshold Impact
    (ETE 1010-01)
    0.85m/s, 3 impacts per caster, all 4 casters, 25 mm step-up.
    Regulations
    Meets or exceeds the following requirements:
    RoHS Compliance Level RoHS:YL
    Safety UL 60950, CB Scheme IEC 950, CSA C22.2 950 from UL
    TUV EN 60950
    UL CB scheme IEC 950 (CE mark)
    RFI/EMI 47 CFR 15B Class A
    EN55022 Class A
    VCCI Class B
    AS/NZ 3548
    CNS 13438
    KSC 5858
    ICES-003
    Immunity IEC 1000
    EN55024 per EMC Directive 89/336/EEC, including
    IEC 61000-4-2 Electrostatic discharge immunity test
    IEC 61000-4-3 Radiated, radio-frequency, electromagnetic field immunity test
    IEC 61000-4-4 Electrical fast transient/burst immunity test
    IEC 61000-4-5 Surge immunity test
    IEC 61000-4-6 Immunity to conducted disturbances, induced by radio frequency fields
    IEC 61000-4-8 Power frequency magnetic field immunity test
    IEC 61000-4-11 Voltage dips, short interruptions and voltage variations immunity tests

    Dimensions and Weights
    Height 4RU - Rack-based system: 17.45 cm (6.87 in.)
    Width 44.5 cm (17.48 in.)
    Depth 64.4 cm (25.4 in.)
    Weight Minimum 31 kg (70 lb.)
    Maximum 37.2 kg (82 lb.)
    Rack Mounting
    Fits into a standard 19-inch-wide rack mount kit that complies with EIA standard