Processor |
Number |
Up to two dual-processor CPU/Memory Boards (2 or 4 CPUs) |
Architecture |
900-MHz, 1050-MHz, or 1200-MHz UltraSPARC III Cu
|
Cache memory |
64-KB data and 32-KB instruction
Secondary: 8-MB external
|
Main
Memory |
Capacities |
8 memory slots (DIMMs) per processor, 16 total slots per CPU/Memory Board
256-MB, 512-MB, or 1-GB expansion (16GB maximum per CPU/Memory board,
32GB maximum when configured with 4 processors)
Note: Install DIMMs in groups of four. 1050MHz & faster CPU/Memory boards
require that all memory DIMM slots be fully populated.
|
Standard
Interfaces |
Ethernet |
Two 10/100/1000BASE-T twisted-pair ethernet ports (RJ-45) |
FC-AL |
One Fibre Channel Arbitrated Loop (FC-AL) high-speed serial data connector
(HSSDC) |
Keyboard and mouse |
USB |
PCI |
Six PCI slots compliant with PCI specification Revision 2.1:
- Two slots (0 & 1) operating at 66-MHz, 64 bits wide, 3.3 volts (full length
slots)
- One slot operating at 33-MHz, 64 bits wide, 5 volts (full-length slot)
- Three slots operating at 33-MHz, 64 bits wide, 5 volts (short slot)
|
Remote System Controller |
One RSC card plugs into a dedicated slot on the system I/O board which
includes integrated modem, serial and Ethernet interfaces.
- One 56 Kbps modem port (RJ-11)
- One EIA-232D serial port (RJ-45)
- One 10 Mbps Ethernet port (RJ-45)
|
Serial |
One RJ45 serial port |
USB |
Two standard Universal Serial Bus (USB)
Type A connectors |
Internal
Mass Storage |
Disks |
Two front-accessible, hot-swappable, FC-AL disks, 36-GB, 73-GB or 146-GB, 3.5-in.
x 1.0-in. 10,000 RPM |
DVD-ROM |
8x DVD-ROM (IDE) drive |
Power
Supplies |
Type |
One required, two for N+1 redundancy (hot swap), each with independent power cord |
Output |
560 W per power supply |
Environment |
AC input |
100 - 240 VAC, 50 - 60 Hz, 8.6 A(max) |
Input power |
1100 W (max)
|
Heat output |
3751 BTU/hr (max)
|
Temperature |
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -20° C to 60° C (-4° F to 140° F) |
Humidity |
Operating: 20%to 80% relative temperature humidity, noncondensing
Nonoperating: 5% to 95% relative temperature humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.)
Nonoperating: 12,000 m (40,000 ft.)
|
Acoustic noise |
Operating: 74.5 dBA
Idling: 74.5 dBA |
Vibration |
Operating: .0002 G/Hz, 5 - 500 Hz (random) (deskside)
.0001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted)
Nonperating: .002 G/Hz, 5 - 500 Hz (random) (deskside)
.001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted)
|
Shock |
Operating: 4G peak, 11 milliseconds half-sine pulse (deskside)
3G peak, 11 milliseconds half-sine pulse (rackmounted)
Nonoperating: 15G peak, 11 milliseconds half-sine pulse (deskside)
10G peak, 11 milliseconds half-sine pulse (rackmounted) |
Number of cords |
2 (max) |
1 Refers to
total input current required for both AC inlets when operating with dual
power supplies or current required for a single AC inlet when operating
with a single power supply. |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL 60950, CSA C22.2 EN 60950 (from U.L.), TUV 60950, UL CB scheme IEC
950 (CE mark), GOST |
RFI/EMI |
Class A:Australia/New Zealand AS/NZ 3548, Industry Canada ICES-003, European
Community EN55022/CISPR22, Japan VCCI, Taiwan CNS 13438, and US FCC 47CFR15.B
|
Immunity |
EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11, IEC 61000-3-2, and IEC 61000-3-3 |
X-ray |
U..DHHS 21CFR Subchapter J,PTB German X-ray Decree |
Dimensions
and Weights |
Height |
22.2 cm (8.75 in.), 5 Rack Units |
Width |
44.6 cm (17.5 in.) |
Depth |
61.0 cm (24.0 in.) |
Weight |
35.8 kg (79 lb.) (minimum)
44 kg (97 lb.) (fully configured) |
Power cord |
2.5 m (8.2 ft) |
Clearance
and Service Access |
Front |
36 in. |
Rear |
36 in. |
Rack
Mounting |
Fits into a standard 19-inch-wide rack mount kit that complies with EIA-310-D-1992
standard, or a 72-inch height Sun StorEdge rack, which will support seven
Sun Fire V480 servers.
A 72-inch Sun StorEdge rack can physically hold up to seven Sun Fire
V480 servers (with a power sequencer there are 36 rack units of usable
space and the Sun Fire V480 is 5 rack units high). A Sun Fire V480 with
a four-way standard configuration running Sun Virtual Test Suite (VTS)
may vary from 750 Watts to 900 Watts depending on the PCI cards installed.
The power sequencer in the StorEdge rack provides ~5400 W.
So, a Sun StorEdge rack can support seven Sun Fire V480 servers if they
are not fully loaded (if the configurations are only two-way or the PCI
slots are not fully populated on a four-way configuration). However, a
Sun StorEdge rack can support only six Sun Fire V480 servers if they are
fully loaded (four-way configurations and/or full PCI slots) and running
a typical workload, like Sun VTS.
|