Processor |
Number |
Up to two dual-processor CPU/Memory Boards (2 or 4 CPUs) |
Architecture |
1.05GHz, 1.35GHz UltraSPARC[tm] IV, 1.5GHz, or 1.8GHz UltraSPARC IV+
|
Cache memory |
Cache (L1): 64-KB data and 32-KB instruction per pipeline
Secondary (L2): 16 MB external (8 MB per pipeline), 2 MB on chip L2 cache
Cache (L3): 32 MB external off-chip (UltraSPARC IV+ processor)
|
Main
Memory |
Capacities |
8 memory slots (DIMMs) per processor, 16 total slots per CPU/Memory Board
512MB, 1GB, or 2GB expansion (32GB maximum per CPU/Memory board,
64GB maximum when configured with 4 processors)
It is REQUIRED to fully populate all memory DIMM's on 2.1GHz, 1.8GHz, 1.5GHz, 1.35GHz, and 1.05GHz CPU/Memory Boards
|
Standard
Interfaces |
Ethernet |
Two 10/100/1000-Mbps Ethernet |
Keyboard and mouse |
USB |
PCI |
Six PCI slots compliant with PCI specification Revision 2.1:
- Two slots (slots 0 & 1) operating at 66-MHz, 64 bits wide, 3.3 volts
- Four slots operating at 33-MHz, 64 bits wide, 5 volts
Note: PCI slots 0, 1, and 2 are full length card slots (12 inch); PCI slots 3, 4, and 5
are short length card slots (7 inch).
|
Remote System Controller |
One ALOM Plus card plugs into a dedicated slot on the system I/O board |
Serial |
One RJ45 serial port |
USB |
Two (compliant with USB Revision 1.0) |
Internal
Mass Storage |
Disks |
Two front-accessible, hot-pluggable, FC-AL disks, 73GB or 146GB, 3.5-in.
x 1.0-in. 10,000 RPM, or 146GB 15,000 RPM, maximum total capacity of 292 GB
|
DVD-ROM |
8X Slimline DVD-ROM (IDE) drive |
Power
Supplies |
Type |
One required, two for redundancy fitted as standard, each with independent power cord
|
Output |
1448 W per power supply |
Environment |
AC Power |
Auto Ranging 200-240 VAC, 50 or 60 Hz, 8A @ 200-240 VAC
|
Input power |
1052 W (max measured), 1600 W (mfg rating)
|
Heat output |
3590 BTU/hr (max measured), 5459 BTU/hr (mfg rating)
|
Temperature |
Operating: 5° C to 35°C (41°F to 95°F)
Nonoperating: -20°C to 60°C (-4°F to 140°F)
|
Humidity |
Operating: 20% to 80% RH noncondensing; 27°C (81°F) wet bulb
Nonoperating: 95% RH noncondensing |
Altitude |
Operating: 0 to 3000 meters (0 to 10,000 feet)
Nonoperating: 0 to 12,000 meters (0 to 40,000 feet) |
Acoustic noise |
Operating: 74.5 dBA
Idling: 74.5 dBA |
Vibration |
Operating: .0001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz
Nonoperating: .001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz |
Shock |
Operating: 3g peak, 11 milliseconds half-sine pulse
Nonoperating: 10g peak, 11 milliseconds half-sine pulse |
Handling Drops
|
25 mm (10 in)
|
Threshold Impact
|
1 meter/second
|
Number of cords |
2 |
Regulations
Meets or exceeds the following requirements: |
Safety |
UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part1040, CNS14336 |
Ergonomics |
EK1-ITB-2000 |
RFI/EMI |
EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3 |
Immunity |
EN55024/CISPR24 |
Regulatory Markings |
CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark |
Telecommunications |
EN300-386 |
X-ray |
DHHS 21 Subchapter J; PTB German X-ray Decree
|
Dimensions
and Weights |
Height |
222 mm (8.75 in)
|
Width |
446 mm (17.5 in)
|
Depth |
610 mm (24 in)
|
Weight |
Min 35.83 kg (79 lbs)
Max 44 kg (97 lbs)
|
Power Cord |
2.5 m (8.2 ft)
|
Clearance and Service Access |
Front Blockage Only |
36 in (92 cm) |
Rear Blockage Only |
36 in (92 cm) |
Front And Rear Blockage |
Front Clearance: 36 in (92 cm)
Rear Clearance: 36 in (92 cm) |