Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] V490 2100, RoHS:YL Server: Hardware Specifications

Processor
Number Up to two dual-processor CPU/Memory Boards (2 or 4 CPUs)
Architecture

2.1GHz UltraSPARC IV+

Cache memory

Cache (L1): 64-KB data and 32-KB instruction per pipeline
Secondary (L2): 16 MB external (8 MB per pipeline), 2 MB on chip L2 cache
Cache (L3): 32 MB external off-chip (UltraSPARC IV+ processor)

Main Memory
Capacities

8 memory slots (DIMMs) per processor, 16 total slots per CPU/Memory Board

512MB, 1GB, or 2GB expansion (32GB maximum per CPU/Memory board, 64GB maximum when configured with 4 processors)
It is REQUIRED to fully populate all memory DIMM's on 2.1GHz CPU/Memory Boards

Standard Interfaces
Ethernet Two 10/100/1000-Mbps Ethernet 
Keyboard and mouse USB
PCI Six PCI slots compliant with PCI specification Revision 2.1:
  • Two slots (slots 0 & 1) operating at 66-MHz, 64 bits wide, 3.3 volts
  • Four slots operating at 33-MHz, 64 bits wide, 5 volts
Note: PCI slots 0, 1, and 2 are full length card slots (12 inch); PCI slots 3, 4, and 5 are short length card slots (7 inch).
Remote System Controller One ALOM Plus card plugs into a dedicated slot on the system I/O board
Serial One RJ45 serial port
USB Two (compliant with USB Revision 1.1)
Internal Mass Storage
Disks Two front-accessible, hot-pluggable, FC-AL disks, 146GB, 3.5-in. x 1.0-in. 15,000 RPM, maximum total capacity of 292 GB
DVD-ROM  8X Slimline DVD-ROM / 24X CD-ROM drive
Power Supplies
Type One required, two for redundancy fitted as standard, each with independent power cord
Output 1448 W per power supply
Environment
AC Power Auto Ranging 200-240 VAC, 50 or 60 Hz, 8A @ 200-240 VAC
Input power 1052 W (max measured), 1600 W (mfg rating)
Heat output 3590 BTU/hr (max measured), 5460 BTU/hr (mfg rating)
Temperature Operating: 5° C to 35°C (41°F to 95°F)
Nonoperating: -20°C to 60°C (-4°F to 140°F)
Humidity Operating: 20% to 80% RH noncondensing; 27°C (81°F) wet bulb
Nonoperating: 95% RH noncondensing
Altitude Operating: 0 to 3000 meters (0 to 10,000 feet)
Nonoperating: 0 to 12,000 meters (0 to 40,000 feet)
Acoustic noise Operating: 74.5 dBA
Idling: 74.5 dBA
Vibration Operating: .0001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz
Nonoperating: .001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz
Shock Operating: 3g peak, 11 milliseconds half-sine pulse
Nonoperating: 10g peak, 11 milliseconds half-sine pulse
Handling Drops
25 mm (10 in)
Threshold Impact
1 meter/second
Number of cords  2
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL/CSA-60950-1, EN60950-1, IEC60950-1 CB Scheme with all country deviations, IEC825-1, 2, CFR21 part1040, CNS14336
Ergonomics EK1-ITB-2000 
RFI/EMI EN55022 Class A, 47 CFR 15B Class A, ICES Class A, VCCI Class A, AS/NZ 3548 Class A, CNS 13438 Class A, KSC 5858 Class A, GB 9254 Class A, EN61000-3-2, GB 17625.1, EN61000-3-3
Immunity EN55024/CISPR24
Regulatory Markings CE, FCC, ICES-003, C-tick, VCCI, GOST-R, BSMI, MIC, UL/cUL, UL/S-mark
Telecommunications EN300-386
X-ray DHHS 21 Subchapter J; PTB German X-ray Decree
Dimensions and Weights
Height 222 mm (8.75 in)
Width 446 mm (17.5 in)
Depth 610 mm (24 in)
Weight Min  35.83 kg (79 lbs)
Max 44 kg (97 lbs)
Power Cord 2.5 m (8.2 ft)
Clearance and Service Access
Front Blockage Only 36 in (92 cm)
Rear Blockage Only 36 in (92 cm)
Front And Rear Blockage Front Clearance: 36 in (92 cm)
Rear Clearance: 36 in (92 cm)

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback