Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4150, RoHS:YL Server: Hardware Specifications

Processor
Number 1 or 2 Dual-Core or Quad-Core
Architecture Type: Intel Xeon Dual-Core or Quad-Core Processors
CPUs Intel 3.00GHz Dual-Core Xeon 5160 (4MB L2, 1333MHz FSB, 80W)
Intel 3.50GHz Dual-Core Xeon X5270 (6MB L2, 1333MHz FSB, 80W)
Intel 1.60GHz Quad-Core Xeon L5310 (8MB L2, 1066MHz FSB, 50W)
Intel 1.86GHz Quad-Core Xeon L5320 (8MB L2, 1066MHz FSB, 80W)
Intel 2.33GHz Quad-Core Xeon E5345 (8MB L2, 1333MHz FSB, 80W)
Intel 2.66GHz Quad-Core Xeon E5355 (8MB L2, 1333MHz FSB, 120W)
Intel 2.00GHz Quad-Core Xeon L5335 (8MB L2, 1333MHz FSB, 50W)
Intel 2.33GHz Quad-Core Xeon E5410 (12MB L2, 1333MHz FSB, 80W)
Intel 2.83GHz Quad-Core Xeon E5440 (12MB L2, 1333MHz FSB, 80W)
Intel 2.66GHz Quad-Core Xeon L5430 (12MB L2, 1333MHz FSB, 50W)
Intel 3.33GHz Quad-Core Xeon X5470 (12MB L2, 1333MHz FSB, 120W)
Main Memory
Capacities Total DIMM slots: 16
DIMM type: PC2-5300 DDR2 667MHz Registered DIMMs (128 bit plus ECC databus)
DIMM size: 1-GB, 2-GB or 4-GB
Maximum capacity: 64GB (when configured with 4-GB DIMMs)
NOTE: DIMMs must be installed in pairs.  Pairs of different densities may be mixed.
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
SAS Eight channel SAS interfaces for internal or external drives with add-on SAS Host Bus Adapter
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Three internal MD2 low profile 8-lane PCI Express slots (all with x16 mechanical connectors)
Internal Mass Storage
Disks SAS: Up to eight internal 2.5" SAS Disks with add-on SAS Host Bus Adapter
Drive Type
Density
Speed
Form Factor
SAS
73 GB
10,000 RPM
2.5"
SAS
73 GB
15,000 RPM
2.5"
SAS
146 GB
10,000 RPM
2.5"
SAS
300 GB
10,000 RPM
2.5"
Solid State Drives Up to four 32GB solid state drives
DVD-ROM One EIDE DVD+/-RW drive
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 650W)
(UL Maximum AC input = 650W x 1.33 efficiency = 865W)
(8.2 Amps RMS at 100 VAC)
Environment
AC power 90-264 V AC (47-63 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3048 m (10,000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise Single, non-rack system:
LwAd (1B=10dB)
     7.7 B at max ambient
LpAm bystander
     65.8 dB at max ambient
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety IEC60950, UL/CSA60950-1, EN60950, CB Scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Dimensions and Weight
Height 44 mm (1.746 in.)
Width (not including ears) 426 mm (16.75 in.)
Width (including ears) 443.9 mm (17.47 in.)
Depth (not including PSU handle) 714 mm (28.125 in.)
Depth (including PSU handle) 736.4 mm (28.99 in.)
Weight 18.4 kg (40.66 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
Rack Mounting
Sun Fire X4150 Server Racks Racks are as follows:
  • Sun Rack 900
  • Sun Rack 1000-38
  • Sun Rack 1000-42
  • Third Party EIA-310-D-1992

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback