Sun Fire X4270 M2 Server: Hardware Specifications

Processor
Number 1 to 2 Intel Quad-Core or 6-Core
Architecture Type: Intel Xeon Quad-Core or 6-Core Processors
CPUs Intel Xeon 2.40 GHz Quad-Core E5620 (12MB L3, 80W)
Intel Xeon 2.93 GHz 6-Core X5670 (12MB L3, 95W)
Intel Xeon 3.33 GHz 6-Core X5680 (12MB L3, 130W)
Main Memory
Capacities Total DIMM slots: 18
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 4-GB 1333MHz or 8-GB 1066MHz
Maximum capacity: 144GB (when configured with 8-GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port
PCI Expansion Slots Six internal MD2 low profile 8-lane PCI Express slots (all with x8 mechanical connectors)
Internal Mass Storage
Disks SAS: Configurations of Up to 12 internal 3.5" or 24 internal 2.5" SAS HDDs with add-on SAS Host Bus Adapter
SATA: 2.5" or 3.5" SATA Solid State Drives supported
Drive Type
Density
Speed
Form Factor
SAS
146 GB
10,000 RPM
2.5"
SAS
300 GB
10,000 RPM
2.5"
SAS
300 GB
15,000 RPM
3.5"
SAS
1 TB
7,200 RPM
3.5"
SAS
2 TB
7,200 RPM
3.5"
Solid State Drive
32 GB
NA
2.5"
Solid State Drive
32 GB
NA
3.5"
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 1200W)
(UL Maximum AC input = 1200W x 1.33 efficiency = 1596W)
(13.0 Amps Max current AC RMS)
Environment
AC power 100-120/200-240 V AC, (50-60 Hz)
Temperature Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing
Altitude Single, non-rack system:
Operating: Up to 3048 m (10000 ft.), maximum ambient temperature is derated by 1° C per 300 m above 900 m
Nonoperating: Up to 12,000 m (40,000 ft.)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL/cUL, CE, BSMI, GOST-R, S-Mark, CSA C22.2 No. 60950-03
RFI/EMI FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Other Complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC)
Dimensions and Weight
Height 87.12 mm (3.43 in.)
Width 425.45 mm (16.75 in.)
Depth 762.0 mm (30 in.)
Weight 29.54 kg (65 lb.)
Rack Mounting
Sun Fire x4270 M2 Server Racks Racks are as follows:
  • Sun Rack II 1042 (Redwood)
  • Sun Rack II 1242 (Redwood)

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.