| Processor |
| Number |
1 or 2 Intel Quad-Core |
| Architecture |
Type: Intel Xeon 5500 series Quad-Core Processors |
| CPUs |
Intel Xeon X5570 2.93 GHz (8MB cache, 6.4 GT/s QPI, SMT, Turbo, 95W)
Intel Xeon X5560 2.80 GHz (8MB cache, 6.4 GT/s QPI, SMT, Turbo, 95W)
Intel Xeon E5540 2.53 GHz (8MB cache, 5.86 GT/s QPI, SMT, Turbo, 80W)
Intel Xeon L5520 2.26 GHz (8MB cache, 5.86 GT/s QPI, SMT, Turbo, 60W)
Intel Xeon E5520 2.26 GHz (8MB cache, 5.86 GT/s QPI, SMT, Turbo, 80W)
|
| Cache memory |
X5570 L2/1MB L3/8MB
X5560 L2/1MB L3/8MB
E5540 L2/1MB L3/8MB
L5520 L2/1MB L3/4MB
E5520 L2/1MB L3/8MB |
| Main Memory |
| Capacities |
Total DIMM slots: 18
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 2-GB, 4-GB, 8-GB 1066MHz or 4-GB 1333MHz
Maximum capacity: 144GB (when configured with 8-GB DIMMs)
|
| Standard
Integrated Interfaces |
| Network |
Four 10/100/1000 Base-T Ethernet Ports
|
| Network Management |
One dedicated 10/100Base-T Ethernet port |
| Serial Management |
One dedicated TIA/EIA-232-F asynchronous RJ45 port |
| SAS |
Four channel SAS interface, internal access only |
| USB |
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port |
| PCI Expansion Slots |
Six internal MD2 low profile 8-lane PCI Express slots
(all with x8 mechanical connectors) |
| Internal Mass Storage |
| Disks |
SAS or SATA: Up to twelve internal 3.5" SAS, SATA or SSD Disks with add-on SAS Host Bus Adapter
Drive Type
|
Density
|
Speed
|
Form Factor
|
SAS
|
300 GB
|
15,000 RPM
|
3.5"
|
SAS
|
450 GB
|
15,000 RPM
|
3.5"
|
SATA
|
1 TB
|
7,200 RPM
|
3.5"
|
Solid State Drive
|
32 GB
|
NA
|
3.5"
|
|
| Power Supplies |
Dual redundant, hot swappable power supplies
(Power supply rating output = 1050W)
(UL Maximum AC input = 1050W x 1.33 efficiency = 1397W)
(8.2 Amps RMS at 100 VAC)
|
| Environment |
| AC power |
90-264 V AC (47-63 Hz) |
| Temperature |
Single, non-rack system:
Operating: 5° C to 35° C (41° F to 95° F)
Nonoperating: -40° C to 70° C (-40° F to 158° F)
|
| Humidity |
Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing,
38° C (100.4° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing |
| Altitude |
Single, non-rack system:
Operating: up to 3048 m (10000 ft.), maximum ambient
temperature is derated by 1° C per 300 m above 900 m
Nonoperating: 15kPa |
| Acoustic noise |
Single, non-rack system:
LwAd (1B=10dB)
7.7 B at max ambient
LwAd bystander
65.8 dB at max ambient
|
Regulations
Meets or exceeds the following
requirements: |
| RoHS Compliance Level |
RoHS:YL |
| Safety |
UL/cUL, CE, BSMI, GOST-R, S-Mark, CSA C22.2 No. 60950-03 |
| RFI/EMI |
FCC CFR 47 Part 15 Class A, EN55022 Class A, EN 61000-3-2,
EN61000-3-3, EN 300-386 |
| Immunity |
EN55024, EN300-386 |
| Certifications |
Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
|
| Other |
Complies with WEEE Directive (2002/96/EC) and RoHS Directive (2002/95/EC) |
| Dimensions and Weight |
| Height |
87.6 mm (3.45 in.) |
| Width |
436.5 mm (17.19 in.) |
Depth |
762.0 mm (30.0 in.) |
| Weight |
29.54 kg (65 lb.) |
| Rack Mounting |
| Sun Fire X4275 Server Racks |
Racks are as follows:
- Sun Rack II 1042 (Redwood)
- Sun Rack II 1242 (Redwood)
|