Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Fire[tm] X4600 M2, RoHS:YL Server: Hardware Specifications

Processor
Number Up to 8
Architecture Type: AMD Opteron 8000 Series

Model
Speed
Core
WATTs
8216 2.4 GHz Dual-Core 95W
8218 2.6 GHz Dual-Core 95W
8220 2.8 GHz Dual-Core 95W
8220SE 2.8 GHz Dual-Core 120W
8222 3.0 GHz Dual-Core 95W
8224SE 3.2 GHz Dual-Core 120W
8347HE 1.9 GHz Quad-Core 55W
8356 2.3 GHz Quad-Core 75W
8360SE 2.5 GHz Quad-Core 105W
8384 2.7 GHz Quad-Core 75W
8389 2.9 GHz Quad-Core 75W
8380 2.5 GHz Quad-Core 75W
Sun Fire X4600 (Model 1) difference: See Model 1 CPU specifications.
The Model 1 uses AMD Opteron 800 series CPUs.
BIOS revisions differ between the AMD Opteron 8000 and 800 series. BIOS downloads are available at: http://www.oracle.com/technetwork/systems/patches/firmware/release-history-jsp-138416.html#X4600
Main Memory
Capacities DIMM slots per CPU Socket: Two configurations: 4 or 8 DIMM Slots
DIMM sizes:1-GB, 2-GB, 4-GB, or 8-GB
Maximum capacity using 4 DIMM Slot CPU/Memory Boards: 256GB (when configured with 8-GB DIMMs and 8 CPU Modules)
Maximum capacity using 8 DIMM Slot CPU/Memory Boards: 512GB (when configured with 8-GB DIMMs and 8 CPU Modules)
Sun Fire X4600 (Model 1) difference: See Model 1 Memory specifications.
The Model 1 uses DDR1/400 memory. DIMM slot locations differ between DDR1 and DDR2 DIMMs. Refer to Sun Fire X4600 and Sun Fire X4600 M2 service documentation for DIMM installation information.
Standard Integrated Interfaces
Network Four 10/100/1000Base-T Ethernet ports, RJ45 connectors
Network Management One dedicated 10/100Base-T Ethernet port, RJ45 connector
Serial Management RS-232 Serial Interface, RJ45 connector
SAS Four channel SAS interface
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Expansion bus 8 Low Profile PCI Expansion slots
  • 2 64-bit/100 MHz PCI-X slots
  • 6 PCIe slots (4 x 8-lane PCI slots, 2 x 4-lane PCI slots)
  • 2 socket configurations ** have:
    3 PCIe slots (2 x 8-lane PCI slots, 1 x 4-lane PCI slots)
Internal Mass Storage
Disks Internal: Up to four 73GB or 146GB HDD Disks (Hot Pluggable 2.5" SAS) RPM 10K.
Up to four 73GB HDD Disks (Hot Pluggable 2.5" SAS) RPM 15K.
DVD-ROM One EIDE DVD-ROM
Power Supplies
Four hot-swappable power supplies, redundant in 2+2 configuration;
Available Power Supplies: 950 Watt, Type A222 and 1133 Watt, Type A238.
Environment
AC power 90-264 V AC (47-63 Hz)
1137 W; 3880 BTU/HR; .32 Tons of Air Conditioning (4xCPU/2HDD/4x2GB/7 PCI cards)
1603 W; 5470 BTU/HR; .46 Tons of Air Conditioning (8xCPU/2HDD/8x2GB/7 PCI cards)
Note:The power results represent the worse-case, maximum sustained total server power for room temps below 23° C
Temperature Single, non-rack system:
Operating: 5° C to 32° C (41° F to 90° F)
Nonoperating: -40° C to 65° C (-40° F to 149° F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27° C (80.6° F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38° C (100.4° F) max wet bulb
Altitude Single, non-rack system:
Operating:32° C up to 900 meters and derating of 1°C for every 300 meters in altitude up to 3048 meters maximum
Nonoperating: up to 12,000 m (40,000 ft.)
Acoustic noise
(Measure and Environment)
Declared noise emissions in accordance with ISO 9296, A-weighted, operating and idling:
Less than 83 dB sound power in ambient temperature of up to 24° C
LwAd (1B=10dB)
at or below 25C
at max ambient

8.1 B
8.9 B
LpAm bystander
at or below 25C
at max ambient

66 dB
74 dB
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety IEC60950, UL/CSA60950-1, EN60950, (CB Scheme with all country differences)
RFI/EMI FCC Class A, Part 15 47 CFR, EN55022, CISPR 22, EN300-386:v1.3.2, ICES-003
Immunity EN55024, EN300-386:v1.3.2
Certifications Safety: cULus Mark, CE Mark, CCC, GOST R, S-Mark
EMC: CE Mark (93/68/EEC), Emissions and Immunity Class A Emissions Levels: FCC, VCCI, BSMI, C-Tick, MIC, CCC (Applicable at GA), GOST R, BSMI
Other: Labeled per WEEE (Waste Electrical and Electrical Equipment) Directive
Dimensions and Weight
Height 176 mm (6.9 in.)
Width 445 mm (17.5 in.)
Depth 629 mm (24.75 in.)
Weight 40 kg (88 lb.) Maximum standalone server
48 kg (106 lb.) Maximum with orderable rack-mount kit and cable management arm
Rack Mounting
Optional Slide Rail Kit (X8095A-Z) is a 4-point mounted slide rail kit.
Optional Slide Rail Kit (X8095A-Z) and optional Cable Management Arm (8094A-Z) enables X4600 to be racked in:
  • Sun Rack 900 (-38 and -36N)
  • Sun Rack 1000 (-38 and -42)
  • Third Party ANSI/EIA-310-D-1992 or IEC 60927 compliant racks in 19-inch/482.6 mm panel width series.
The slide kit includes hardware that enables mounting to any of the following types of rack rails:
  • M6 threaded holes
  • #10-32 threaded holes
  • #10 to M6 clearance holes
  • Square unthreaded holes per EIA and IEC starndards listed above
Rack Density: Sun Fire X4600 Server Rack Density will vary widely based on systems installed, power distribution installation (in-cabinet, external), power source (single-phase, three-phase) and whether redundant power is required.

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback