Sun Microsystems, Inc.   Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Sun Ultra[tm] 25, RoHS:Y Workstation: Hardware Specifications

Processor
Number One
The processor communicates with the system I/O through the 167MHz Jbus interface.
Architecture 1.34GHz UltraSPARC IIIi:
Cache memory 1MB Level 2
Main Memory
Capacities Characteristics of the DDR-1 ECC-protected memory include:
  • Maximum system memory - 8GB (using 2GB DIMMS)
  • Maximum DIMMS - 4 (8GB max)
  • Maximum DIMM slots - 4
  • Two physical banks of two DIMMs
  • DIMM sizes offered - 512MB, 1GB, or 2GB
  • DDR-1 registered ECC memory at 266 MHz
  • Processor accesses memory across the 128-bit data bus. Must be installed in pairs.
Standard Interfaces
Audio Four AC97 ports as follows:
  • Two in front
  • Two in rear
Ethernet Two 10/100/1000 BaseT (Gigabit) ethernet ports (rear of workstation)
Expansion Slots Five slots as follows:
  • Two PCI-Express: both mechanical (x16) and electrically (x8)
  • One PCI-Express mechanical (x8) and electrically (x4)
  • Two PCI-X 100MHz/64 bit slots
Serial Two ports (rear of workstation)
USB Six ports as follows:
  • Two USB 2.0 ports in front
  • Four USB 2.0 ports in rear
Internal Storage
Disks Allows a maximum of four internal 3.5" SAS (146GB - 15000 RPM) or SATA (80GB or 250GB - 7200 RPM) disk drives. Drives are supported by an integrated PCI-X SAS/SATA disk controller.
Optical Disk Drives Optical disk drive as follows:
  • One 8x DVD-RW/24x CD-RW (Slot-loading)
  • ATAPI - Interface
Note: Systems that ship without an optical disk drive require an optical disk drive EMI filler panel in the unoccupied bay to cover the slot opening.
Graphics
Cards Note: Solaris 10 currently does not support dual graphics cards, each driving a monitor.
Environment
AC Power Voltage: 110-127/200-240 VAC
Frequency: 50-60 Hz, 10/6 Amps
Input Current 6.4 amps @ 100 VAC, 3.2 amps @ 200 VAC
Power consumption Power Supply - 1000 Watts (maximum)
Temperature Operating: 2° C to 35° C (41° F to 95° F) at 3000 meters
Nonoperating:-40° C to 68° C (-40° F to 158° F) at 12000 meters
Humidity Operating: 7% to 93% relative humidity, non-condensing
Nonoperating: 93% relative humidity, non-condensing
Acoustic noise Operating:LWAd (1B=10db) 5.0 B
LpAm (by standard position) 42 dBA
Idling: LWAd (1B=10db) 4.5 B
LpAm (by standard position) 38 dBA
Shock Operating: 5 G's, 11 msec, half-sine
Nonoperating: 30 G's, 11 msec, half-sine
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:Y
Safety IEC60950 CB, UL/CSA-60950, EN60950
RFI/EMC Class B, FCC CFR47, part 15 Class B; EN 6100-3-2, EN 61000-3-3
Immunity EN55024 All applicable levels
Regulatory Markings UL/cUL, TUV-GS, CE FCC, VCCI, ICES-003, CCC, C-tick, GOST-R, MIC, S-Mark, EEE, BSMI
Ergonomics EK1-1TB-2000, RFI/EMC, EN 55022/CISPR22
Power Management EPA MOU 3 (Supports PowerNow standard ACPI power states for Windows)
Dimensions and Weights
Height 445 mm (17.5 in)
Width 205 mm (8.1 in)
Depth 569 mm (22.4 in)
Weight 26.31 kg (58 lbs) fully configured depending on configuration

  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.