Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1000228.1 : Battery replacement may cause BOTH sides of CACHE or shared memory to blockade leading to a total system outage.
PreviouslyPublishedAs 200303 Product Sun StorageTek 9910 Sun StorageTek 9960 System Impact Battery assembly maintenance or replacement may cause one half, or ALL of CACHE or SM to become blocked. The issue can occur under the following conditions:
Noise generated by incoming current during battery connection may cause the backup switching circuit on the CACHE PCB to fail, which may cause both sides of CACHE or SM to become blocked. If both sides of CACHE or SM are blocked, the array will experience a complete system outage and possibly DATA LOSS. MICRO-PROGRAM VERSIONS: All Microcode Levels of SE9900 Series Symptoms
Resolution Ensure microcode level DKCMAIN 01-19-44-00/00 or above is on the subsystem prior to performing battery replacement. Do not perform scheduled battery maintenance at this time on the BASIC battery assemblies unless following the new replacement instructions. The new instructions require the removal of the corresponding BAT-CTR during battery replacement. The new BASIC battery assembly replacement instructions are as per the details provided in HDS Alert: 9960#136G / 9910#110G. The alert is available for review via:
These new instructions are MANDATORY. Microcode has been modified to display the new battery replacement procedures on the SVP as a step by step procedure beginning with DKCMAIN 01-19-44-00/00. Modification History Date: 15-JUL-2005
Previously Published As 100561 Internal Comments
Related Information
Internal Contributor/submitter Ross.Keeley@sun.com Internal Eng Business Unit Group KE Authors Internal Eng Responsible Engineer Ross.Keeley@sun.com Internal Services Knowledge Engineer Joe Davis Internal Kasp FAB Legacy ID 100561, I1037-1 (FIN) Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: Avoidance: Patch Responsible Manager: null Original Admin Info: [WF 15-JUL-2005, Joe; updating per ross keely, pete on vacation] Product_uuid 2a918ae2-0a18-11d6-834a-c679537eebe7|Sun StorageTek 9910 2a94fb3c-0a18-11d6-90a8-c9c08656284f|Sun StorageTek 9960 System Attachments This solution has no attachment |
||||||||||||
|