Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1000682.1 : Array performance degradation as a result of the cache changing to write-through.
PreviouslyPublishedAs 200894 Product Sun StorageTek 3310 SCSI Array Sun StorageTek 3510 FC Array Sun StorageTek 3320 SCSI Array Sun StorageTek 3511 SATA Array Bug Id <SUNBUG: 6327514>, <SUNBUG: 6256792> Impact Firmware 4.1x introduced a new functionality to decide when the cache changes to write-through. This is the auto-write-through-trigger. One of the triggers is battery-backup-failure which, when enabled, will change the cache to write-though should a battery fail. However, this trigger does not distinguish between a battery failure and a re-charge cycle. As a result, performance of the array degrades to add to the performance hit already caused by the 4.1x firmware. Symptoms Battery re-charging messages indicating the re-charging cycle, followed by the cache changing to write-through. Consequently a drop in i/o performance. <Tue Jan 24 02:06:43 2006> Controller BBU is Charging ! <Tue Jan 24 02:06:44 2006> Force Controller Write-Through on Trigger Cause <Tue Jan 24 05:55:12 2006> NOTICE: Controller BBU Fully Charged ! <Tue Jan 24 05:55:12 2006> Controller Default Write Policy Restore Root Cause The controller firmware 4.1x is unable to distinguish between a battery failure and a battery re-charging event. Workaround Patch Information per Array:
Resolution
Previously Published As 102222 Internal Comments
Internal Contributor/submitter Naz.Bhanji@Sun.COM Internal Eng Business Unit Group KE Authors Internal Eng Responsible Engineer Tejinder.Singh@Sun.COM Internal Services Knowledge Engineer sean.hassall@sun.com Internal Escalation ID 1-12760796 Internal Resolution Patches 113723-15, 113724-09, 113722-15, 113730-01 Internal Kasp FAB Legacy ID 102222 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: Avoidance: Firmware Responsible Manager: null Original Admin Info: null Internal SA-FAB Eng Submission Bug 6327514 causes array performance degradation as a result of the cache changing to write-through. Product_uuid 3db30178-43d7-4d85-8bbe-551c33040f0d|Sun StorageTek 3310 SCSI Array 58553d0e-11f4-11d7-9b05-ad24fcfd42fa|Sun StorageTek 3510 FC Array 95288bce-56d3-11d8-9e3a-080020a9ed93|Sun StorageTek 3320 SCSI Array 9fdbb196-73a6-11d8-9e3a-080020a9ed93|Sun StorageTek 3511 SATA Array Attachments This solution has no attachment |
||||||||||||
|