Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1000696.1 : Java W/S W1100z & W2100z Rear Fan Fault
PreviouslyPublishedAs 200909 Product Sun Java Workstation W2100z Sun Java Workstation W1100z Symptoms
The Sun Java Workstation W2100z and W1100z may experience a Rear Fan fault
when the "System Cooling" parameter is set to "Normal" in BIOS R01B3S1 and
BIOS R01B4S0.
To confirm this is a fan fault in your Sun Java Workstation W2100z and W1100z you must reset the "System Cooling" parameter to its default setting of "Aggressive". If you still experience a failure in your system then the latest BIOS R01B4S2 should be used prior to fan replacement. For more information refer to: http://pts-platform.uk/twiki/bin/view/Products/ProdIssuesW1100Z Previously Published As 101917 Internal Eng Business Unit Group KE Authors Internal Kasp FAB Legacy ID 101917 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: Avoidance: Responsible Manager: null Original Admin Info: null Product_uuid 126e9e72-9b14-11d8-ab52-080020a9ed93|Sun Java Workstation W2100z 4dcfccb6-9b12-11d8-ab52-080020a9ed93|Sun Java Workstation W1100z Attachments This solution has no attachment |
||||||||||||
|