Solution  1000815.1 :   Sun Ultra 20 Workstation with 4 x 1GB of memory will not power on.  


Related Items
  • Sun Ultra 20 Workstation
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Hardware Remediation>Reactive
  •  

PreviouslyPublishedAs
201094


Product
Sun Ultra 20 Workstation

Part
  • Part No: 300-1794-02 (or below)
  • Part Description: 400 Watt Power Supply
Xoption
  • Xoption Number: x8006A
  • Xoption Description: 2GB (2 * 1GB DDR400/PC3200 ECC DIMM) Option

Impact

System will not power on.


Contributing Factors

Any Ultra 20 with 4 x 1GB of memory and a 300-1794-02 (or below) power supply is exposed. There is no Sun shipped configuration for the Ultra 20 with 4 x 1GB of memory. The 4 x 1GB memory configuration can only be obtained by upgrading the system via a memory xoption.


Symptoms

Sun Ultra 20 Workstations loaded with 4 Gigabites of memory and containing the -01 or -02 power supply can drive the power supply to the edge of its performance limits resulting in a system that will not power on.

In the Bios it is possible to configure a system to either power down in the event of a power issue or reboot. If a system is set to power down and this issue occurs, it will simply power down and, upon manual re-power, it will power itself down again. If a system is set to automatically reboot and this issue occurs the system will enter a continuous cycle of automatically powering down and trying to reboot only to power down again.

Corrective action has been made available in Manufacturing via ECO WO_32375 cut-over as of January 30, 2006, and in Services via GSAP 3309 issued on February 7,2006.


Root Cause

The validated root cause of this problem has been determined to be specific components within the power supply itself. Two capacitors and a diode have been changed to increase the power margins. Accordingly, the power supply has been dash rolled to -03 to reflect the upgraded version that has the margins to successfully support a 4 x 1GB memory configuration.

The validated corrective action to resolve this issue in the field is to replace the power supply with an updated power supply should a system loaded with 4 x 1GB of memory fail to power on.


Workaround

 


Resolution
Replacement Time Estimate: 30 minutes (per PSU)
Hot Swappable: No
Upon failure only replace as follows: Replace                with -------                ---- 300-1794-02 (or below) 300-1794-03 (or above) or 300-1950-01 (or above)

 


Previously Published As
102544
Internal Comments


Note: This Hardware FAB went through planning under FCO# A0268-1.



Hardware Remediation Details

This FCO will have a time zone phased release based on material readiness as follows:





Readiness Date
--------------
US/Canada Jul/27/06
Ltn America Aug/07/06
EMEA Jul/31/06
APAC Aug/09/06
ANZO Aug/09/06
Japan Aug/09/06


The above dates represent when each time zone has determined that it will be materially ready to support this FCO. All dates are estimates. Please check with your Logistics Representative or TZ / Country / Area FCO Manager for more information with regard to material availability and the parts ordering process for this FCO.


Related Information
  • ECO: WO_32375
  • GSAP: 3309.A

Internal Contributor/submitter
michaelt.hardin@sun.com

Internal Eng Business Unit Group
NSG (Network Systems Group)

Internal Eng Responsible Engineer
Chris.Kaminaris@Sun.COM

Internal Services Knowledge Engineer
joe.davis@sun.com

Internal Kasp FAB Legacy ID
102544

Internal Sun Alert & FAB Admin Info
Critical Category:
Significant Change Date: 2006-07-31
Avoidance: Hardware Replacement
Responsible Manager: Matthew.Koehler@Sun.COM
Original Admin Info: WF - joe released on 7-31-2006.

WF - karen and joe created 7-27-2006. Joe working as part of Tiger Team
see sunwebcollab folder. Waiting for closure on purge.

Internal SA-FAB Eng Submission
------------------------------------------------------------------------

*** Sun Confidential: Internal Use and Authorized VARs Only ***
________________________________________________________________________

This message including any attachments is confidential information
of Sun Microsystems, Inc. Disclosure, copying or distribution is
prohibited without permission of Sun. If you are not the intended
recipient, please reply to the sender and then delete this message.
________________________________________________________________________

FIELD CHANGE ORDER
(For Authorized Distribution by Sun Services)


FCO #: A0268-1 DATE: July 13, 2006

SYNOPSIS: Sun Ultra 20 Workstation with 4 x 1GB of memory will not
power on.

Sun Alert: No

TOP FIN/FCO REPORT: No

PRODUCT REFERENCE: Ultra 20 Workstation

PRODUCT CATEGORY: Server / Memory - Server / Power

PRODUCT AFFECTED:

Systems Affected:
------- --------
Mkt_ID Platform Model Description Serial Number
------ -------- ----- ----------- -------------
- A63 - Sun Ultra 20 Workstation -

X-Options Affected
--------- -------
Mkt_ID Platform Model Description
------ -------- ----- -----------
x8006A - - 2GB (2 * 1GB DDR400/PC3200 ECC DIMM) Option


AFFECTED PARTS:

Part Number Description
----------- -----------
300-1794-02 (or below) 400 Watt Power Supply


REFERENCES:

ECO: WO_32375
GSAP: 3309


ISSUE DESCRIPTION:

Sun Ultra 20 Workstations loaded with 4 Gigabites of memory and containing
the -01 or -02 power supply can drive the power supply to the edge of its
performance limits resulting in a system that will not power on.

Any Ultra 20 with 4 x 1GB of memory and a 300-1794-02 (or below) power supply
is exposed. There is no Sun shipped configuration for the Ultra 20 with
4 x 1GB of memory. The 4 x 1GB memory configuration can only be obtained by
updgrading the system via a memory xoption.

In the Bios it is possible to configure a system to either power down in the
event of a power issue or reboot. If a system is set to power down and this
issue occurs, it will simply power down and, upon manual re-power, it will
power itself down again. If a system is set to automatically reboot and
this issue occurs the system will enter a continuous cycle of automatically
powering down and trying to reboot only to power down again.

The validated root cause of this problem has been determined to be specific
components within the power supply itself. Two capacitors and a diode have
been changed to increase the power margins. Accordingly, the power supply
has been dash rolled to -03 to reflect the upgraded version that has the
margins to successfully support a 4 x 1GB memory configuration.

The validated corrective action to resolve this issue in the field is to
replace the power supply with an updated power supply should a system
loaded with 4 x 1GB of memory fail to power on.

Corrective action has been made available in Manufacturing via ECO WO_32375
cut-over as of January 30, 2006, and in Services via GSAP 3309 issued on
February 7,2006.


IMPLEMENTATION:

---
| | MANDATORY (Fully Proactive)
---

---
| | CONTROLLED PROACTIVE (per Sun Geo Plan)
---

---
| X | REACTIVE (Upon Failure)
---


IMPLEMENTATION TARGET COMPLETION DATE: Not Applicable

REPLACEMENT TIME ESTIMATE: 30 minutes (per PSU)

SPECIAL CONSIDERATIONS:

This FCO will have a time zone phased release based on material readiness
as follows:

Readiness Date
--------------
US/Canada Jul/27/06
Ltn America Aug/07/06
EMEA Jul/31/06
APAC Aug/09/06
ANZO Aug/09/06
Japan Aug/09/06

The above dates represent when each time zone has determined that it will
be materially ready to support this FCO. All dates are estimates. Please
check with your Logistics Representative or TZ / Country / Area FCO Manager
for more information with regard to material availability and the parts
ordering process for this FCO.


CORRECTIVE ACTION:

Hot Swappable: No

Upon failure only replace as follows:

Replace with
------- ----
300-1794-02 (or below) 300-1794-03 (or above) or 300-1950-01 (or above)


COMMENTS:


CHANGE HISTORY:

Jul/xx/06 - Initial release.

________________________________________________________________________


For questions on this document, please email:

finfco-manager@Sun.com

The FCO home page is available at:

http://tns.central/fco

For more information on how to submit a FCO, go to:

http://pronto.central/fco.html

To access the Service Partner Exchange, use:

https://spe.sun.com


NOTE: FCO Tracking Instructions for Radiance/SPWeb:
--------------------------------------------------

If a Radiance case involves the application of an FCO to solve a customer
issue, please complete the following steps in Radiance/SPWeb prior to
closing the case:

o Select "Field Change Order" in the REFERENCE TYPE field.

o Enter FCO ID number in the REFERENCE ID field.
For example; A0257-1.

If possible, include additional details in the REFERENCE SUMMARY field
(ie. Upgrade complete, customer declined, etc.)


Implementation Notes
--------------------

In case of "Mandatory" FCOs, Sun Services will attempt to contact
all known customers to recommend proactive implementation.

For "Controlled Proactive" FCOs, Sun Services mission critical
support teams will initiate proactive implementation efforts for
their respective accounts, as required.

For "Upon Failure" FCOs, Sun Services and partners will implement
the necessary corrective actions as the need arises.

The CIC process must be used for proactive hardware replacement
requests when an FCO is classified as "Upon Failure".


Billing Information
-------------------

Warranty: Sun will provide parts at no charge under Warranty
Service. On-Site Labor Rates are based on specified
Warranty deliverables for the affected product.

Contract: Sun will provide parts at no charge. On-Site Labor Rates
are based on the type of service contract.

Non Contract: Sun will provide parts at no charge. Installation by
Sun is available based on the On-Site Labor Rates
defined in the Price List.