Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1001326.1 : Sun Fire[tm] X4100 and X4200 ILOM Upgrade Procedure Flaws
PreviouslyPublishedAs 201788 Product Sun Fire X4100 Server Sun Fire X4200 Server Bug Id <SUNBUG: 6415975> Impact
Symptoms Failing to follow the instructions to apply the supplied pre-flash script prior to the flash upgrade may corrupt the ILOM service processor. Error messages may be seen on the ILOM service processor serial management port, such as: ........................................................... ....................................umount: /conf: device is busy umount: /conf: device is busy Node totlen on flash (0xffffffff) != totlen in node ref (0x000002c8) Node totlen on flash (0xffffffff) != totlen in node ref (0x0000070c) This issue has presented itself if, after the ILOM flash upgrade occurs, it is not possible to login to the ILOM service processor via the serial management or network management port. Resetting the ILOM/BIOS password via the password jumper does not help. The ILOM service processor may also print other error messages or not display a login prompt. Root Cause Root cause can be attributed to an intermittent failure to unmount the /conf partition during an "sp flash upgrade" or "flush filesystem blocks" procedure. Workaround Follow the instructions in the Sun Fire X4100 and X4200 Product Notes (.pdf file), and apply the supplied pre-flash script to ILOM service processors, prior to performing flash upgrade. See the Product Notes and pre-flash README file, for detailed information and examples on how to automate application of the pre-flash script. Future releases of ILOM service processor firmware will correct the deficiency. Note: In the event that flash corruption occurs, a manual flash recovery process is available (see "Recovering from a Failed Flash Update" in Sun Fire X4100 and Sun Fire X4200 Servers Product Notes for details on manual recovery). It is a very complicated process, which may completely corrupt the ILOM service processor flash if done incorrectly, which will then need to be replaced. Modification History Date: 27-JUN-2006
Date: 27-JUN-2006
Previously Published As 102325 Internal Comments None. Hardware Remediation Details
Related Information
Internal Contributor/submitter Christopher.P.Johnson@sun.com Internal Eng Business Unit Group KE Authors Internal Eng Responsible Engineer Patrick.Boyle@sun.com Internal Services Knowledge Engineer sean.hassall@sun.com Internal Kasp FAB Legacy ID 102325 Internal Sun Alert & FAB Admin Info Critical Category: Significant Change Date: Avoidance: Service Procedure Responsible Manager: null Original Admin Info: null Internal SA-FAB Eng Submission The Sun Fire[tm] X4100 and X4200 Servers provide a combined ILOM service processor and bios upgrade option. Flaws have been discovered in the ILOM upgrade feature, which may result in corruption of the ILOM service processor firmware, and motherboard SUN FRU id record. This is most likely to occur if the server remains powered on at the beginning of the flash update, or if the service processor configuration is preserved during upgrade. Product_uuid 54e2ac49-df71-11d9-89e6-080020a9ed93|Sun Fire X4100 Server c6e795ef-df6f-11d9-89e6-080020a9ed93|Sun Fire X4200 Server Attachments This solution has no attachment |
||||||||||||
|