Solution Type FAB (standard) Sure Solution 1019584.1 : Misaligned spring connectors on CSM200 midplanes can cause HDD signal integrity issues for StorageTek 5320/5220 and 6140 Controller trays and CSM200 Expansion trays.
PreviouslyPublishedAs 241666 Bug Id <SUNBUG: 6649674> Product Sun StorageTek CSM200 Expansion Tray Sun StorageTek 6140 Array Sun StorageTek 5320 NAS Appliance Sun StorageTek 5220 NAS Appliance Date of Resolved Release 05-Sep-2008 Contacts in the Amphenol connector can become deformed (see details below). Affected Parts: 540-6545-03 CSM200 Drive Cage Midplane ImpactCustomers may experience excessive drive failures. Replacement drives may also show the same or similar symptom, but not necessarily immediately. If the customer looses a disk that cannot be promptly replaced the loss of a second disk could expose customer to unnecessary risk of data loss.Contributing FactorsSystems with CSM200 Drive Cage Midplane (Sun p/n 540-6545-xx) having a serial number between 0805DHG05N and 0810DHG00R are affected by this issue.Contacts in the Amphenol connector can become deformed during drive connector insertion and may not spring back to it's normal position. Depending on the extent of the damage this issue may be intermitent or solid. SymptomsHDD signal integrity errors.Systems experiencing this issue will see intermittent drive off-line condition. Drives will have appeared to have failed normally and or be in a by-passed state. Subsequent replacements into the same slot may appear to resolve the issue but the drive may fail again. Other times drive replacement will not change the failed condition. Root CauseThe root cause was attributed to a pin placement/alignment issue within an Amphenol connector used on the midplane assemblies. The supply vendor has stopped using the Amphenol connector and has switched to alternate suppliers. Systems shipped after approximately March 10, 2008 are NOT impacted by this issue per StopShip/Purge P001-20497.Corrective ActionWorkaround:No workaround available - see Resolution section below. Resolution: Upon failure only replace the 540-6545-03 (if in the suspected list below) with 540-6545-03 (or above) and not in the suspected list. This knowledge asset does NOT authorize pro-active remediation. Identification of Affected Parts (how to): Examine the rear of the CSM200 Chassis for the serial number. If it falls between 0805DHG05N and 0810DHG00R, you must check it against the list of suspected trays found at... http://pts-storage.west/products/SE6130/FAB_DATA/AmphenolList.ods If the serial number is on the list and the tray is exhibiting the issues described above, the midplane chassis assembly should be replaced. Proper steps for replacing a failed midplane can be found in the Common Array Manager (CAM) Service Advisor or in the Drive Cage Replacement Procedure document EK1732-1-E2 for arrays that are managed by SANtricity. The EK1732-1-E2 document can be located via the below link; http://sdpsweb.central/FIN_FCO/FAB/241666/SPE/Drive_Cage_Replacment_ProcedureEK1732-1-E2.pdf An example of what a damaged connector might look like can be found at: http://pts-storage.west/products/SE6130/FAB_DATA/Amphenol.pdf Note to Authorized Service Partners: Sun Authorized Service Partners may contact Sun Services or their Sun Services Representative to receive FAB related information, including Customer details. CommentsSun Engineering is confident that the suspect trays list linked above contains all of the affected units. If you encounter these symptoms on a tray not on the list but within the range of serial numbers, you should conduct a close visual inspection of the connectors and, if there are any doubts, replace the midplane using the procedures outlined in CAM's Service Advisor or SANtricity's Recovery Guru.This issue was fully evaluated as an FCO and determined not to meet criteria due to the relatively low number of suspected units and the small potential of exposure (approximately 3%) to this issue. References: BugID: 6649674 Other References: PITT 1931 WW Stop Ship: P001-20497 For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: For Sun Authorized Service Providers go to: In addition to the above you may email: Internal Contributor/submitter Bob.Deguc@Sun.COM Internal Eng Responsible Engineer Bob.DeGuc@Sun.COM Responsible Manager: Kyle.Mayle@Sun.COM Internal Services Knowledge Engineer Joe.Davis@Sun.COM Internal Eng Business Unit Group NWS (Storage) Internal Sun Alert & FAB Admin Info 03-Sep-2008: Completed draft and sent to Extended Review. 05-Sep-2008: No feedback from Ext Rvw - sending to Publish. 08-Dec-2009: Corrected Product Name to swoRDFish inconsistency. Attachments This solution has no attachment |
||||||||||||
|