Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1019938.1 : Booting from DVD fails or DVD drive not recognized on Netra T5220 and Netra T5440.
PreviouslyPublishedAs 249386 Bug Id <SUNBUG: 6774335>, <SUNBUG: 6766240>, <SUNBUG: 6804349> (was <SUNBUG: 6789861>) Date of Resolved Release 14-Jan-2009 Product Sun Netra T5220 Server Sun Netra T5440 Server Netra T5220/T5440 panics attempting to boot from TEAC DVD drive or fails to recognize DVD drive (see details below). Affected Parts: 540-7563-XX TEAC DV- DV-W28SLC-0Z3 DVD drive (390-0403) 371-2532-07 (or below) Netra T5220 Power Distribution Board 371-3648-06 (or below) Netra T5440 Power Distribution Board ImpactSun's supply partner shipped TEAC DVD drives and Power Distribution Board (PDB), Sun part number 371-2532-06 in late 2008 for the T5220. In most cases, usage of this vendor's drive with this version PDB revision -06 and system FW 7.1.7.c (or earlier) is associated with panics during DVD boot of Solaris 10 Update 5. Initially manufacturing removed the TEAC drive (Sun p/n 540-7563-xx) from production of the Netra T5220 as a workaround. The final fix for the panic issue was to upgrade the PDB to part number 371-2532-08, or upgrade PDB FW to TUSB -06 and to upgrade to system FW 7.1.7.h. This fix was delivered in early 2009 which also works for the TEAC drive.In some cases the Netra T5220 and Netra T5440 would not recognize the DVD after power on in the new FW configuration, and in some older ones. Contributing FactorsThese issues affect the Netra T5220 and Netra T5440 systems, with TEAC DVD drives (drive p/n 390-0403) and with Power Distribution Board (part numbers 371-2532-06 or 371-3648-05), or systems with Power Distribution Board (part numbers 371-2532-07 or 371-3648-06).SymptomsThe system panics during boot from DVD. Example error message below:{0} ok boot cdrom - install Boot device: /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2/disk@0:f File and args: - install SunOS Release 5.10 Version Generic_120011-14 64-bit Copyright 1983-2007 Sun Microsystems, Inc. All rights reserved. Use is subject to license terms. Cannot mount root on /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2/disk@0,0:b fstype ufs panic[cpu0]/thread=180e000: vfs_mountroot: cannot mount root 000000000180b950 genunix:vfs_mountroot+32c (800, 200, 0, 1867c00, 1892800, 18bb400) %l0-3: 00000000010ba400 00000000010ba29c 000000000186d788 00000000011df000 %l4-7: 00000000011df000 00000000018bd800 0000000000000600 0000000000000200 000000000180ba10 genunix:main+98 (181ad40, 1017c00, 183d180, 18b7c00, 70002000, 181ac00) %l0-3: 0000000070002000 0000000000000001 000000000180c000 000000000180e000 %l4-7: 0000000000000001 000000000180c000 0000000000000060 0000000000000000 skipping system dump - no dump device configured rebooting... The system could also fail to recognize the DVD, as follows (on Netra T5440): {0} ok cd /pci@400/pci@0/pci@1/pci@0/usb@0,2/hub@4/storage@4/disk@0:f Device not found Root CauseFirmware on Power Distribution Board part numbers 371-2532-07 (or below) and 371-3648-06 (or below), and Netra T5220 system FW 7.1.7.h (and earlier) and Netra T5440 system FW 7.1.7.e (and earlier) is the cause of these issues.Corrective ActionWorkaround:The system FW should be upgraded to 7.1.8.b for the Netra T5220 and 7.1.8.a for the Netra T5440. Please note that system FW 7.1.8.b is newer than 7.2.1, so care must be taken for higher releases. Also, the PDB FW should be upgraded remotely to usb6250-08 for the T5220 and the T5440 via the following process: 1. Request the firmware file "v04.02.12.22.562AD423.hex" (or higher) from Don Draygalski (Donald.Drygalski@Sun.COM). Place it on any server that is reachable by the Turgo system which is getting programmed. 2. Make sure that an IP address is entered in the /etc/ethers of the tftp server (see doc 205300) where the Turgo system is with the ethernet address of the Turgo system entered with an IP address. 3. Power on the Netra system and get to the ok prompt. 4. From the ok prompt do the following three steps a. ok 4000 dload v04.02.12.22.562AD423.hex or "file-name with complete path" For example: {0} ok 4000 dload v04.02.12.22.562AD423.hex Boot device: /pci@0/pci@0/pci@1/pci@0/pci@2/network@0:,|v04.02.12.22.562AD423.hex File and args: 1000 Mbps full duplex Link up Requesting Internet Address for 0:14:4f:97:a7:d4 Requesting Internet Address for 0:14:4f:97:a7:d4 Requesting Internet Address for 0:14:4f:97:a7:d4 b. Then type this command: {0} ok 4000 file-size @ eval Target 1 Sending ten commandments ... last line should give 9 0 8 0 ... 8 0 9 0 Target 2 Start sending data! 0 Sent initial five-byte crud! 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ... 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c. Then type this command: {0} ok reset-all d. Check to see whether the dvd is recognized {0} ok probe-scsi-all MPT Version 1.05, Firmware Version 1.22.00.00 Target 0 Unit 0 Disk SEAGATE ST914602SSUN146G0603 286739329 Blocks, 146 GB SASAddress 5000c50006793db9 PhyNum 0 Target 1 Unit 0 Disk SEAGATE ST914602SSUN146G0603 286739329 Blocks, 146 GB SASAddress 5000c50006d0d1b1 PhyNum 1 /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2 Unit 0 Removable Read Only device TSSTcorpCD/DVDW TS-T632ASR03 e. Check the DVD FW Version: {0} ok cd /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2 {0} ok .properties device_type scsi-usb configuration# 00000001 bulk-in-size 00000200 bulk-in-pipe 00000002 bulk-out-size 00000200 bulk-out-pipe 00000001 serial$ AAFBA02E3D1D device$ 6250 FW: 04.02.12.22.562AD423 vendor$ Texas Instruments Incorporated compatible usb451,625f.200 Note: Netra 5440 DVD properties are at: /pci@400/pci@0/pci@1/pci@0/usb@0,2/hub@4/storage@4 f. Power off the host from the SC with 'poweroff -y' and then power on with 'poweron -c' . Resolution: The FW update described in the Workaround above will resolve this issue. CommentsNoneReferences: BugID: 6789861 Radiance ID: 66156571, 66166574, 70448848 For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: For Sun Authorized Service Providers go to: In addition to the above you may email: Modification History Changes since initial Publication. Date: 20-Jan-2009
Internal Contributor/submitter Donald.Drygalski@Sun.COM, Robert.Balfour@Sun.COM Internal Eng Responsible Engineer Jim.Ye@Sun.COM Responsible Manager: Art.Weigel@Sun.COM Internal Services Knowledge Engineer Joe.Davis@Sun.COM Internal Eng Business Unit Group SSG NSN (Netra Systems and Networking) Internal Sun Alert & FAB Admin Info 09-Jan-2009: Completed draft and sent to Extended Review. 14-Jan-2009: Addressed all feedback - sending to Publish. 22-Jan-2009: Added Netra T5440 as affected product and new Root Cause & Corrective Action info.. 11-Feb-2009: Added step f in workaround section. 06-Mar-2008: Corrected several steps in Resolution section. Attachments This solution has no attachment |
||||||||||||
|