Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1266267.1
Update Date:2011-02-10
Keywords:

Solution Type  FAB (standard) Sure

Solution  1266267.1 :   Sun Flash F5100 ASR Activation will not work with CAM version 6.6 or lower.  


Related Items
  • Sun Flash F5100 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  




In this Document
  Symptoms
  Changes
  Cause
  Solution


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: FABs available to Internals and Partners only

Applies to:

Sun Flash F5100 Array - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Information in this document applies to any platform.
__________

SUNBUG 6950805


Affected Parts:

541-3143 - Motherboard Assembly
501-7696 - Power Distribution Board

Symptoms

The customer will only notice that the ASR activiation process did not complete. The ASR internal SAMs server will note the customer activation did not complete, with the following error message given, "Investigation - Serial not found".

Impact

Customer will encounter that Auto Service Request (ASR) will not complete the activation process during ASR set-up while a F5100 Array is managed with CAM version 6.6 or lower. The customer may incorrectly believe their F5100 Array is being monitored.

Changes

Contributing Factors

Common Array Manager (CAM) version 6.6 (or below) running one of the following Sun Flash F5100 Array configurations:

  • TA5100RASA4-20AA - 480GB solid state Flash array with 20 x 24GB SATA enterprise-class SLC Flash modules
  • TA5100RASA4-40AA - 960GB solid state Flash array with 40 x 24GB SATA enterprise-class SLC Flash modules
  • TA5100RASA4-80AA - 1.92TB solid state Flash array with 80 x 24GB SATA enterprise-class SLC Flash modules

Cause

Root Cause

CAM version 6.6 (or lower) pulls the motherboard assembly WWN.  ASR expects the system serial number, which is programmed within the power distribution board assembly and is physically located on the F5100 front left bezel.

Solution

Workaround

No workaround available - see Resolution section below.

Resolution


Customer must install CAM version 6.7 (or greater), which pulls the expected system serial number found on the power distribution board assembly. This will allow the ASR activation process to complete successfully.

CAM 6.7 can be found at the below URL;

 http://www.sun.com/storage/management_software/resource_management/cam/get_it.jsp

References

SUNBUG 6950805



For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL:

* http://tns.central/fab

In addition to the above you may email:

* FAB-Manager@sun.com

@ Contacts

@ Contributor:  pete.babich@oracle.com
@ Responsible Engineer:  mark.vetter@oracle.com
@ Responsible Manager:  randy.luckenbihl@oracle.com
@ Business Unit Group:  chris.vanbuhler@oracle.com

@ NWS (Network Storage)

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback