Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition | |||
|
|
Solution Type FAB (standard) Sure Solution 1308220.1 : Using incorrect mounting screws to secure the Netra T5440 rack mount can cause damage to internal components.
In this Document
Oracle Confidential (PARTNER). Do not distribute to customers
Applies to:Sun SPARC Enterprise T5440 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/AInformation in this document applies to any platform. __________ Affected X-Options: X4061A - 19" 4-post Slide Mount Kit Affected Parts: 350-1276 - 19-inch 4-post Slide Mount Kit SymptomsPower supplies cannot be removed from the chassis and/or internal LED cable may be damaged leading to abnormal LED functionality.Impact Using the wrong screws to secure the rack mount kit to the Netra T5440 could result in internal component damage to the server. ChangesContributing FactorsScrews from rack mount package 2492712 must be used to secure the rack mount to the server. Using the longer 8mm screws from the other packages will interfere with internal component movement and/or could damage internal components. Reference the attached documents showing pictures of both correct and incorrect screws in their packaging, as well as pictures showing the wrong screw installed in a unit. CauseRoot Cause19" 4-post Slide Mount Kit (X4061A) is used by multiple types of servers so different size screws are delivered with this kit. There have been instances of the wrong screws being used to attach the rack mount to the Netra T5440 chassis. SolutionWorkaroundNo workaround available - see Resolution section below. Resolution Screws from rack mount package (plastic bag) labeled 2492712 must be used to secure the rack mount to the Netra T5440. If incorrect screws were used, they must be replaced by screws from package 2492712. Identification of Affected Parts (how to) The screws used to secure the rack mount to the Netra T5440 chassis should have threads that are 5mm in length. The 19" 4-post Slide Mount Kit (X4061A) already contains the correct screws as identified above. References MOS ID: 3-2913198671, 3-2913434508, 3-2835264587, 3-2913434527, 3-2913434536, 3-2913434545, 3-291343455,3-2913434563, 3-2913434572, 3-2913434601, 3-2913434610 Contacts Contributor: donald.drygalski@oracle.com Responsible Engineer: mark.a.white@oracle.com Responsible Manager: Tom.Kelly@Oracle.com Business Unit Group: Systems Group-Netra Systems and Networking For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL: https://sunspace.sfbay.sun.com/display/Onestop/FAB%20(Field%20Action%20Bulletin) In addition to the above you may email: * FAB-Manager_US@Oracle.COM Attachments This solution has no attachment |
||||||||||||
|