Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-73-1308220.1
Update Date:2011-03-30
Keywords:

Solution Type  FAB (standard) Sure

Solution  1308220.1 :   Using incorrect mounting screws to secure the Netra T5440 rack mount can cause damage to internal components.  


Related Items
  • Sun SPARC Enterprise T5440 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Sun FAB>Standard>Reactive
  •  




In this Document
  Symptoms
  Changes
  Cause
  Solution


Oracle Confidential (PARTNER). Do not distribute to customers
Reason: FABs available to Internals and Partners only

Applies to:

Sun SPARC Enterprise T5440 Server - Version: Not Applicable to Not Applicable - Release: N/A to N/A
Information in this document applies to any platform.
__________

Affected X-Options:

X4061A - 19" 4-post Slide Mount Kit

Affected Parts:

350-1276 - 19-inch 4-post Slide Mount Kit

Symptoms

Power supplies cannot be removed from the chassis and/or internal LED cable may be damaged leading to abnormal LED functionality.

Impact


Using the wrong screws to secure the rack mount kit to the Netra T5440 could result in internal component damage to the server.

Changes

Contributing Factors

Screws from rack mount package 2492712 must be used to secure the rack mount to the server. Using the longer 8mm screws from the other packages will interfere with internal component movement and/or could damage internal components.

Reference the attached documents showing pictures of both correct and incorrect screws in their packaging, as well as pictures showing the wrong screw installed in a unit.

Cause

Root Cause

19" 4-post Slide Mount Kit (X4061A) is used by multiple types of servers so different size screws are delivered with this kit. There have been instances of the wrong screws being used to attach the rack mount to the Netra T5440 chassis.

Solution

Workaround

No workaround available - see Resolution section below.

Resolution

Screws from rack mount package (plastic bag) labeled 2492712 must be used to secure the rack mount to the Netra T5440.

If incorrect screws were used, they must be replaced by screws from package 2492712.

Identification of Affected Parts (how to)

The screws used to secure the rack mount to the Netra T5440 chassis should have threads that are 5mm in length. The 19" 4-post Slide Mount Kit (X4061A) already contains the correct screws as identified above.

References

MOS ID: 3-2913198671, 3-2913434508, 3-2835264587, 3-2913434527, 3-2913434536, 3-2913434545,
3-291343455,3-2913434563, 3-2913434572, 3-2913434601, 3-2913434610

Contacts

Contributor: donald.drygalski@oracle.com
Responsible Engineer: mark.a.white@oracle.com
Responsible Manager: Tom.Kelly@Oracle.com
Business Unit Group: Systems Group-Netra Systems and Networking

For information about FAB documents, its release processes, implementation strategies and billing information, go to the following URL:

https://sunspace.sfbay.sun.com/display/Onestop/FAB%20(Field%20Action%20Bulletin)

In addition to the above you may email:

* FAB-Manager_US@Oracle.COM


Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback