Solution  1001760.1 :   Sun StorEdge[TM] T3 - Warning: Device has not been removed from the slot and is still in the loop map  


Related Items
  • Sun Storage T3 Array
  •  
Related Categories
  • GCS>Sun Microsystems>Storage - Disk>Modular Disk - Other
  •  

PreviouslyPublishedAs
202401


Symptoms

When trying to physically remove a Sun StorEdge T3 Disk Tray from a server using luxadm, the following error message is reported.:

# luxadm remove_device [-F] <WWN T3 >
"Device: <pathname> Warning: Device has not been removed from the slot and is still in the loop map."

This error is reported after physically removing the T3 and hitting <Return>:



Resolution

1. # luxadm remove_device -F <WWN T3>

2. Once the prompt tells you to remove the device, and you hit <Return>, telnet into the Sun StorEdge T3 Disk Tray and unmount all volumes

3. On the server performing the luxadm remove_device command, hit <Return> to remove the device paths from the OS.



Product
Sun StorageTek T3 Array

Internal Comments

sophia.hill@sun.com


See Also: Bug ID <BugID>4410483</BugID>


Previously Published As
41697

Change History
Date: 2003-05-20
User Name: Administrator
Action: Migration from KMSCreator
Comment: updated by : Wendy Bean
comment : No comment
date : Mar 1, 2002



updated by : Sophia Hill
comment : Article created.
date : Nov 28, 2001



updated by : Sophia Hill
comment : No comment
date : Nov 28, 2001



updated by : Matthew Teeter
comment : No comment
date : Nov 28, 2001
Version: 0
Product_uuid
2a6d7d50-0a18-11d6-8e0b-f0bd33b24928|Sun StorageTek T3 Array

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback