Sun Microsystems, Inc.  Sun System Handbook - ISO 3.4 June 2011 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-1002417.1
Update Date:2010-06-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  1002417.1 :   Missing drv/clone forceload in /etc/system on a system with Emulex cards may cause panic during boot  


Related Items
  • Sun Fire E6900 Server
  •  
  • Sun Fire E25K Server
  •  
  • Sun Fire E20K Server
  •  
  • Sun Fire 3800 Server
  •  
  • Sun Fire 6800 Server
  •  
  • Sun Fire E4900 Server
  •  
  • Sun Fire 12K Server
  •  
  • Sun Fire 4800 Server
  •  
  • Sun Fire V1280 Server
  •  
  • Sun Fire E2900 Server
  •  
  • Sun Fire 15K Server
  •  
  • Sun Fire 4810 Server
  •  
Related Categories
  • GCS>Sun Microsystems>Servers>Midrange V and Netra Servers
  •  
  • GCS>Sun Microsystems>Servers>High-End Servers
  •  
  • GCS>Sun Microsystems>Servers>Midrange Servers
  •  

PreviouslyPublishedAs
203384


Symptoms
Sun[TM] systems with Emulex cards may panic during boot if the /etc/system file is missing the following entry, or the entry is commented out:
forceload: drv/clone

The following is an example of what you might see during boot (example taken from a Sun Fire[TM] 15K domain with Emulex cards in the configuration):

WARNING: Cannot create minor node for <pci10df,fa00> <lpfc> <0>
Can't find clone devinfo node
NOTICE: Attach failure: Unable to create LAN node
WARNING: pcisch5 (pci@fc,600000): PCI fault log start:
PCI excessive retry error
pcisch5 (pci@fc,600000): PBM AFSR=0x20000030.40000000<config-space> dwordmask=0 bytemask=30
pcisch5 (pci@fc,600000): PCI primary error (8):
Excessive Retries
pcisch5 (pci@fc,600000): PCI secondary error (0):
pcisch5 (pci@fc,600000): PBM AFAR 0.00000900:WARNING: pcisch5: PCI config space CSR=0x2a0
pcisch5 (pci@fc,600000): PCI fault log end.
panic[cpu256]/thread=10408000: pcisch-5: PCI bus 2 error(s)!


Resolution
Boot CDROM or boot net to add/uncomment the forceload for drv/clone in the /etc/system file.

Emulex driver for Solaris[TM] requires drv/clone to be forceloaded in the /etc/system file.



Product
Emulex LightPulse LP8000 Fibre Channel PCI Host Bus Adapter
Sun Fire V1280 Server
Sun Fire E6900 Server
Sun Fire E4900 Server
Sun Fire E2900 Server
Sun Fire 6800 Server
Sun Fire 4810 Server
Sun Fire 4800 Server
Sun Fire 3800 Server
Sun Fire E25K Server
Sun Fire E20K Server
Sun Fire 15K Server
Sun Fire 12K Server

Internal Comments
For internal Sun use only.

This document contains normalized content and is managed by the the Domain Lead(s) of the respective domains. To notify content owners of a knowledge gap contained in this document, and/or prior to updating this document, please contact the domain engineers that are managing this document via the Document Feedback alias(es) listed below:

Normalization team alias: Feedback_MSG_Domain@sun.com
Domain Lead: joshua.freeman@sun.com

Emulex, panic, clone, devinfo, PCI, pcisch, normalized
Previously Published As
82876

Change History
Date: 2010-04-21
User Name: 84789
Action: Reviewed
Comment: Reviewed

Attachments
This solution has no attachment
  Copyright © 2011 Sun Microsystems, Inc.  All rights reserved.
 Feedback